Simple UPS N. SHARMA


TESTED

Santosh Vasudeven
This circuit is a UPS, the circuit provides output voltage is maintained by the rechargeable batteries.
a constant regulated 5 Volt output and battery. The ability to maintain the regulated
an unregulated 12 Volt supply. In the Resistor R1 and D1 are the charging supply with no electrical supply
event of electrical supply line failure the path for battery B1. D1 and D3 prevent depends on the load applied to the UPS
battery takes over, with no spikes on the LED1 being illuminated under power and also the capacity of the battery. If
regulated supply. fail conditions. you were using a 12 Volt 12 AH battery
This circuit can be adapted for other D2 must be included in the circuit, and load from the 5 Volt regulator was
regulated voltages by using different without D2 the battery would charge 0.5 Amp then the regulated supply
regulators. LED 1 will light only when from the full supply voltage without would be maintained for around 24
the electricity supply is present, with a current limit, which would cause dam- hours. Greater A/h capacity batteries
power failure the LED will go out and age and overheating of some would provide a longer standby time.

X1 230 V AC PRIMARY TO 0-12V, 1A D5


SECONDARY TRANSFORMER IN IC1 OUT
7805 +VE
D1-D7=IN4007
R1 R2 COM
1K 100W D6 D7
X1
D1 D2

230V AC
50Hz C2 C3
Battery 12V

+ 0.1µF 0.1µF
D4 D3 LED1

C1
2200µF
25V
–VE