Fleet Management Limited PRESSURE TEST AND INSPECTION RECORD FOR CARGO HOSES

Hose Diameter Rated Working Pressure Test Pressure

Hose No.

Maker

Serial Number

Date

Hose No.

Before Pressure Test


Length (mtr) Visual Condition

At Rated Working Pressure (Duration > 5 minutes)


Length (mtr) Visual Condition

At Test Pressure (Duration > 5 minutes)


Length (mtr) Visual Condition

After Pressure Test


Length (mtr) Visual Condition

Remarks : 1. The cargo hoses should be pressure tested 1.5 times the Rated Working Pressure (RWP) every 6 months. 2. During the pressure test, if any signs of leakage or excessive elongation / significant distortion is noticed, such hose should be immediately scrapped. 3. The temporary elongation should not exceed 1.5 times the temporary elongation when the hose assembly was new. 4. The Electrical Continuity of the hose must be checked upon completion of the pressure test and log down in TKR-19.

____________________________ Chief Engineer/Chief Officer

__________________ Master

TKR-17A

REV 0 / 03-09