Parameters of Air Cooled Mini Chiller Air Cooled Mini Chiller HWAC 03/D HWAC 05/D HWAC 05 HWAC

06 HWAC 08 HWAC 10 HWAC 12 HWAC 15 Parameters Type HWAC HWAC HWAC HWAC HWAC HWAC HWAC HWAC 08H 03H/D 05H/D 05H 06H 10H 12H 15H Cooling Capacity KW 7.1 13 13.3 16 21.8 26 32 39 Heating Capacity KW 7.2 13.5 13.8 16.5 23 27.5 34 41.5 Heating Capacity of Heat Recovery KW 5 10 10 12 16 22 25 31 Power supply 220V/1PH-50HZ 380V/3PH-50HZ Cooling Power Input KW 2.9 4.2 4.28 5.4 7 9.8 12.8 14.5 Heating Power Input KW 3 4.25 4.3 5.5 7.1 10 13.6 15 high and low pressure protection, anti-frozen protection, over load protection, phase order protection, Protection Devices over-heat protection of compressor Operation Equipment microcomputer control automatically, failure warning Switch Device for Cooling/Heating four-way directional control valve Type hermetic rotary compressor hermetic scroll compressor Compressor Power KW 2.23 2.232 3.75 4.5 3.75+2.23 3.752 4.52 3.753 Type copper tube with aluminum fin Fan Type ultra-low noise axial type Air Side Heat vertical side blowing/vertical top Air Blowing Direction vertical side blowing/horizontal Exchanger blowing/horizontal 3 Air Flow m /h 4000 6200 6200 6800 8000 11000 12500 15000 Fan Power KW 0.1 0.25 0.25 0.37 0.12 0.252 0.372 0.52 Type stainless steel plate/high efficiency shell and tube Water Side Heat Water Resistance kpa 30 35 35 39 42 45 45 46 Exchanger Connecting Pipe in 1" 1" 1" 1" 1 3 Water Flow m /h 1.6 2.8 2.8 3.5 4 4.8 6.2 8.2 External Pressure Water Pump m 22 22 22 22 22 20 20 20 Head Rated Power KW 0.55 0.55 0.55 0.55 0.75 0.75 1.1 1.5 Refrigerant R22/R407C

Internal Expansion Water Tank Operation Noise Level Net Weight Length Unit Dimensions Width Height

L 5 dB(A) 56 kg 136 mm 800 mm 500 mm 1200

8 58 130 800 500 1200

58 156 1000 550 1600

58 200 1200 550 1600

60 260 1600 800 1600

61 300 1600 800 1600

61 360 1600 800 1700

63 580 1800 1000 1700

Note: 1. "H" means heat pump type, "D" means single phase power supply. 2. Nominal cooling condition: outside air temperature DB35/WB24, chilled water temperature 12/7. 3. Nominal heating condition: outside air temperature DB7/WB6, chilled water temperature 40/45. 4. The units contain water pump and expansion tank. 5. Owing to technological advances, the above specifications are subject to change without notice. 6. If any other special specifications are needed, please notify us in advance.

You might also like