INSPECTION REPORT(IR)

Date Project/customer Job No Name of vendor

Report No
QA / AVK / 0002 Place of visit

Doc No :F/QA/IR/02 Issue/Rev no:01/01


P.O No & Date

10th,11th,12th and 14.09.2012


Sl No

SOLAR POWER 50MW

PW SO1103

M/s GRINDWELL NORTON LTD


Drg Approved Yes/No Quantity Offered Accepted

BANGALORE

1000006510
Sampling plan

Item Description

Drawing No / Part No

Rework / Hold

Rejected

Item SI.No

SUPPLY OF SOLGLIDE BEARINGS(OD-176 X 69), PART NO: TALS313EG

100% - VISUAL

F12-20520,REV:03

YES

4949

4301

*230

**418
RANDOM DIMENSION

Inspection Category : Stage /

Final

QAP Appd.: Yes / No

QAP Ref : CP/PP559

No of visits : 01(4-DAYS)

1.Visual Inspection:( Welding quality / Finish / Surface Condition etc )

SOLGLIDE BEARINGS ARE 100% VISUALY INSPECTED AND FOUND AS BELOW DEFECTS 418 NOS DEEP SCRATCHES / MARKS, AIR POCKETS, BLACK DOTS ON THE 'PTFE' AREA 230 NOS IMPERFECTION OF EPOXY COAT ON THE BEARINGS
2.Dimensions: ( Attach continuation sheets if required )

REF. ATTACHED DIMENSION CHECK SHEET


3.NDE :

NA
4. Any other tests as per P.O / QAP:

NIL
5.Deviations if any :

NIL
6.Documents Reviewed/ : Internal Inspection Report, Raw Material Tcs, Calibration Certificates, Routine TC, Attached Guarantee Certificate, Compliance Report, Type Test Certificate, Painting Report
Photograph Recorded NDE

Others (Specify): 7.Identification Marks & Inspector Seal :

ACCEPTED MATERIALS ARE PACKED IMMEDIATELY AND THE SAME SEALED BY SEPC(40 X 88 BOXES) AND BALANCE QTY UNDER PACKING
8. Surface Preparation and Preservation:

SURFACE PREPARATION (BLACK CATHODEIC ELECTROCOAT) HAS MADE BY M/s GRINDWELL NORTON,THE SAME INSPECTED AND OBSERVATION AS ABOVE.(PERFORMANCE TEST CERTIFICATES AVAILABLE)
9. Conclusion :
#

THE ABOVE SAID SOLGLIDE BEARINGS ARE ACCEPTED(4301 NOS) AND CLEARED FOR FURTHER PROCESS,SUBJECTED TO SATISFACTORY ACCEPTANCE AND PERFORMANCE AT SITE. BALANCE MATERIALS TO BE INSPECTED BY M/s GRINDWELL NORTON AND SEND REPORT FOR FURTHER ACTION

*230 NOS #

KEPT UNDER REWORK DUE TO IMPERFECTION OF SURFACE COATING. REJECTED DUE TO DEEP SCRATCHES / MARKS, AIR POCKETS, BLACK DOTS ON THE 'PTFE' AREA

**418 NOS -

Vendor Representative Stamp & Signature