Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

Production Part Approval Dimensional Test Results

ORGANIZATION: LEAR CORPORATION " RAMOS PLANT " SUPPLIER / VENDOR CODE: AN INSPECTION FACILITY: "RAMOS" PLANT
ITEM DIMENSION / SPECIFICATION SPECIFICATION / LIMITS TEST DATE QTY TESTED

PA GE: 1 OF: 2

L0070139AA04 PART NUMBER: FOAM FRAME PART NAME: AA04 DESIGN RECORD CHANGE LEVEL:
ENGINEERING CHANGE DOCUMENTS:

ECN X0086307 / N024795

ORGANIZATION MEASUREMENT RESULTS ( DATA )

OK

NOT OK

OK CONSIDERED

2
A2

OK CONSIDERED

3
A1

OK CONSIDERED

4
A3

OK CONSIDERED

OK CONSIDERED

6 7 8

50.95 C-C 40.81

REFERENCE

30-Jun-07

1 piece

50.78 mm OK CONSIDERED

X X X

REFERENCE

30-Jun-07

1 piece

40.97 mm

9 10 11

90.88 263.35 101.73

REFERENCE

30-Jun-07 30-Jun-07

1 piece 1 piece 1 piece

90.62 mm 263.66 mm 181.9 mm

X X X

REFERENCE

30-Jun-07

12

50.94

REFERENCE

30-Jun-07

1 piece

50.24 mm

13 14 15 16 17 18

263.35 20.99 194.78 SECTION C - C MATCHED AREA MUST BE FREE OF FOAM, 2 SIDES
T1

REFERENCE REFERENCE REFERENCE

30-Jun-07 30-Jun-07 30-Jun-07

1 piece 1 piece 1 piece

262.98 mm 20.45 mm 194.71 mm OK CONSIDERED OK CONSIDERED

X X X X X X

SECTION 1357

3.0 mm

30-Jun-07

6 pieces

LACKING MATERIAL MAX. 0.0, 0.0, 0.0,. 0.0, 1.9, 0.0 mm REMAINING MATERIAL MAX. 0.8, 1.4, 1.4, 1.6, 2.1, 2.1 mm

19

T2

SECTION 1272

3.0 mm

30-Jun-07

6 pieces

LACKING MATERIAL MAX. 0.0, 0.0, 1.2, 0.0, 2.1, 0.0 mm REMAINING MATERIAL MAX. 2.1, 0.2, 0.6, 1.6, 2.1, 2.1, mm

20

T3

SECTION 1187

3.0 mm

30-Jun-07

6 pieces

LACKING MATERIAL MAX. 0.0, 0.0, 0.0, 0.0, 0.0, 0.0 mm REMAINING MATERIAL MAX. 2.4, 2.1, 1.6, 0.9, 2.1, 1.7 mm

21

T4

SECTION 1102

3.0 mm

30-Jun-07

6 pieces

LACKING MATERIAL MAX. 0.0, 0.0, 0.0, 1.2, 0.4, 0.0 mm REMAINING MATERIAL MAX. 2.0, 1.4, 2.1, 1.9, 0.8, 0.9 mm

22

T7

SECTION -100

3.0 mm

30-Jun-07

6 pieces

LACKING MATERIAL MAX. 0.0, 0.0, 0.0, 1.6, 0.0, 0.0 mm REMAINING MATERIAL MAX. 0.9, 2.1, 2.1, 0.6, 2.1, 2.1 mm

23

T6

SECTION 0 - 0

3.0 mm

30-Jun-07

6 pieces

LACKING MATERIAL MAX. 0.0, 0.0, 0.0, 0.0, 0.4, 1.0 mm REMAINING MATERIAL MAX. 1.4, 2.1, 2.1, 1.6, 2.0, 2.1 mm

24

D-D

OK CONSIDERED

25

T5

SECTION 100

3.0 mm

30-Jun-07

6 pieces

LACKING MATERIAL MAX. 0.0, 0.0, 1.2, 2.1, 0.8, 0.0 mm REMAINING MATERIAL MAX. 2.1, 1.2, 2.1, 2.1, 1.4, 2.1 mm

26

MATCHED AREAS MUST BE FREE OF FOAM, (5PLCS)

OK CONSIDERED

Blanket statements of conformance are unacceptable for any test results

March 2006 CGF-1003

SIGNATURE GUADALUPE MARTINEZ

TITLE APQP ENG.

DATE 7/7/2007

Production Part Approval Dimensional Test Results


ORGANIZATION: LEAR CORPORATION " RAMOS PLANT " SUPPLIER / VENDOR CODE: AN INSPECTION FACILITY: "RAMOS" PLANT
ITEM DIMENSION / SPECIFICATION SPECIFICATION / LIMITS TEST DATE QTY TESTED

PA GE: 2 OF: 2

L0070139AA04 PART NUMBER: FOAM FRAME PART NAME: AA04 DESIGN RECORD CHANGE LEVEL:
ENGINEERING CHANGE DOCUMENTS:

ECN X0086307 / N024795

ORGANIZATION MEASUREMENT RESULTS ( DATA )

OK

NOT OK

27

173.8

REFERENCE

30-Jun-07

1 piece

173.42 mm

28

21.47

REFERENCE

30-Jun-07

1 piece

21.56 mm

29

70.83

REFERENCE

30-Jun-07

1 piece

70.82 mm

30

20.93

REFERENCE

30-Jun-07

1 piece

20.71 mm

31

299.5

REFERENCE

30-Jun-07

1 piece

299.13 mm

32

SECTION D - D

REFERENCE

30-Jun-07

1 piece

OK CONSIDERED

33

38.1

REFERENCE

30-Jun-07

1 piece

38.4 mm

34

2" SPHERE 01/2" DEF WITH A 1lb PRELOAD SPEC 20 5 N

OK CONSIDERED SEE PERFORMANCE TEST RESULTS

35

131.7

REFERENCE

30-Jun-07

1 piece

131.14 mm

Blanket statements of conformance are unacceptable for any test results

March 2006 CGF-1003

SIGNATURE GUADALUPE MARTINEZ

TITLE APQP ENG.

DATE 7/7/2007

You might also like