Input Data Fish_Tank_Volume := 1m

Fish_Culture_Density := 15 Daily_feed_rate := 1% Feed_Proteine := 45% SSA := 300 m m


2 3

kg m
3

Biofiltration Capacity Biomass := Fish_Tank_Volume Fish_Culture_Density Daily_feed_system := Biomass Daily_feed_rate TAN_day := 0.065 Daily_feed_system Feed_Proteine TAN_day = 3.949 Biofilter_volume_required := mg L Biomass = 15 kg Daily_feed_system = 0.15 kg 0.9 Fish_Tank_Volume TAN_day = 0.004 kg m
3

why is 0.5mg/L ?
Flow_rate_required_day :=

TAN_day Fish_Tank_Volume SSA mg 1m 0.5 Biofilter_volume_required = 26.325 L L

why is 1m?

TAN_day 0.5 mg L

Fish_Tank_Volume

Flow_rate_required_day = 7897.5 L

is the same 0.5mg/L ?


Flow_rate_required_hour :=

Flow_rate_required_day 24 Flow_rate_required_hour = 329.063 L

Oxigen Capacity kg m
3

I add the Oxigen Capacity for the air pump


Oxigen_day = 0.252 kg m
3

Oxigen_day := 1.2 0.21

1kg feed = 0.21 kg/m3 O2 + 20% supliment

Oxigen_required_day := Oxigen_day

Daily_feed_system 1kg

I am not sure about this formula

Oxigen_required_day = 0.038

kg m
3

Flow_rate_required_oxigen_day :=

Oxigen_required_day 1 mg L

Fish_Tank_Volume

Flow_rate_required_oxigen_day = 37800 L

I am not sure about this formula

Flow_rate_required_oxigen_hour :=

Flow_rate_required_oxigen_day 24

Flow_rate_required_oxigen_hour = 1575 L

Mineralisation Capacity

1kg feed = 0.25 kg/m3 Solids


Solid_waste_output_day = 0.038 kg

Solid_waste_output_day := 0.25 Daily_feed_system Solid_waste_concentration_day := Solid_waste_output_day Fish_Tank_Volume

Solid_waste_concentration_day = 37.5 Ci := Solid_waste_concentration_day C' := 7.8 mg L + 0.063 Solid_waste_concentration_day Ci = 37.5 C' = 10.162 mg L

mg L

mg L

This formula is from Kadlec and Knight ?


Requierd_solid_waste_concentration := 15 mg L Ce := Requierd_solid_waste_concentration Ce = 15 := ln mg L

Ce C'

Ci C'

= 1.732

This formula is from Kadlec and Knight ?


Flow_rate_required_day 3000m Surface_area_filter = 4.16 m
2

Surface_area_filter := 2.5 365

why is 2.5 and 3000m ?


Depth_filter := Biofilter_volume_required Surface_area_filter Depth_filter = 0.006 m

Biofilter_volume_required = 0.026 m

I add the depth filter chosen by me

Depth_filter_chosen := 0.3m Water_Flow_hour := Biofilter_volume_required Depth_filter_chosen

Lenght_filter_chosen := 0.3m 3000m 2.5 365 Water_Flow_hour = 0.167 m


3

I add water flow recalibrate


Surface_area_filter_chosen := Biofilter_volume_required Depth_filter_chosen

Water_Flow_hour = 166.58 L

I add water area filter recalibrate


Number_of_pieces_sponges :=

Surface_area_filter_chosen = 0.088 m Surface_area_filter_chosen 2 Depth_filter_chosen Lenght_filter_chosen

I add number of sponges for the new biofilter

Number_of_pieces_sponges = 0.488

You might also like