Material Properties:: All Components Unless Specified: M25 Grade For Columns Up To Ground and First Floor: M30 Grade

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Material properties:

Concrete All components unless specified : M25 grade For columns up to ground and first floor : M30 grade Steel HYSD reinforcement of Fe 415 conforming to IS 1786 is used throughout. Storey Height : 5m

Reinforcement details of Critical Sections of beams

Reinforcement details at critical sections of Columns


Interior columns Ground floor : 16 - 25 First floor : 14 - 25 Second, third and fourth floor : 12- 26 Fifth floor : 12- 25 All columns have 5 legged confining hoops 8@100mmc/c Exterior columns Ground floor :14 - 25 First floor : 14 - 25 Second, third and fourth floor : 12- 25 All columns have 5 legged confining hoops 8@100mmc/c Fifth floor : 10- 25 confining hoops of 4 legged 8 @ 100mmc/c

Evaluation using FEMA 356 Site class D, Ss = 1.0, S1 = 0.4, Inherent damping = 0.05

Status of Hinges at Target displacement = 0.311m at roof level. Structure is at Life Safety Performance level for the given Earthquake for the specified site conditions.

Evaluation using ATC- 40 Structural Behaviour type B Ca = 0.4 , Cv = 0.4, Inherent damping = 0.05

The status of Hinges at Performance Point = 0.176 m at roof level.