In Climatic Test report [Ref.

21] the following non-compliances have been found: - Tests are performed on T3 climatic class in a temperature range that not cover RAD.ER.001.0 SR [Ref. 14] requirement; - The product tested has a module number (EW30099900617) different from the one CE marked in the document [Ref. 31] (EW30099900635), so more details about these module numbers are necessary (differences and impact analysis). - Acceptance Criteria are not detailed; - Performance Check is not reported both during testing temperature and after th at at normal room temperature.