Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

JC International Limited RC.

413243
CUSTOMER: SEADRILL

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: WEST POLARIS

LOCATION:
REPORT NO.

P.O.NO.
3012

W.O.NO.
DATE: 15/03/2012

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS


DS-1 STANDARD.CAT. 3-5 CATEGORY 1 2 3-5 HDLS ALL DIMENSIONS IN INCHES SPECIFICATION: BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia. PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
SRG

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

Dia

Width

Conn. Lead Tong Length Guage Space

Cond.

MPI on Length Critical (Ft.) Area

REMARK

SAVER SUB SD 089 -

PIN x- PIN- CONNECTION-

5.1/2 FH 7.5/8 REG VAM EIS

8.5/8

6.25/3 2

N/A

N/A

5.5/8

N/A

N/A

ACC

ACC 0.85

8.5/8

8.1/2

23/32

6.5/16 5.1/4

N/A

N/A

ACC

ACC

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

1 0 0 0 1

COMMENTS:

ACCEPTABLE AS AT THE TIME OF INSPECTION

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

SIMON OGBAN
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: SEADRILL

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: WEST POLARIS

LOCATION:
REPORT NO.

P.O.NO.
3013

W.O.NO.
DATE: 03/03/2012

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS


DS-1 STANDARD.CAT. 3-5 CATEGORY 1 2 3-5 HDLS ALL DIMENSIONS IN INCHES SPECIFICATION: BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia. PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
SRG

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

Dia

Width

Conn. Lead Tong Length Guage Space

Cond.

MPI on Length Critical (Ft.) Area

REMARK

CROSS OVER SUB WPO 104 6.5/8 FH 8 7.3/4 11/16 6.7/8 N/A N/A N/A

20.5/1 6 ACC

5.1/2 FH

6.3/4

N/A

N/A

5.5/8

N/A

20.19/ ACC 32

ACC 3.51

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

1 0 0 0 1

COMMENTS:

ACCEPTABLE AS AT THE TIME OF INSPECTION

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

SIMON OGBAN
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: SEADRILL

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: WEST POLARIS

LOCATION:
REPORT NO.

P.O.NO.
3014

W.O.NO.
DATE: 03/03/2012

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia. PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
SRG

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

Dia

Width

Conn. Length

ALL DIMENSIONS IN INCHES MPI on Length Tong Lead Critical Cond. (Ft.) Guage Space Area

REMARK

CROSS OVER SUB WPO 109 6.5/8 FH 8.1/32 7.3/4 11/16 6.7/8 N/A N/A N/A

20.3/8 ACC

5.1/2 FH

6.31/32

6.23/32

N/A

N/A 5.11/16 N/A

20.3/8

ACC

ACC 3.49

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

1 0 0 0 1

COMMENTS:

ACCEPTABLE AS AT THE TIME OF INSPECTION

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

SIMON OGBAN
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER:SEADRILL

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: WEST POLARIS

LOCATION:
REPORT NO.

P.O.NO.
3015

W.O.NO.
DATE: 03/03/2012

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS


DS-1 STANDARD.CAT. 3-5 CATEGORY 1 2 3-5 HDLS ALL DIMENSIONS IN INCHES SPECIFICATION: BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia. PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
SRG

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

Dia

Width

MPI on Length Conn. Lead Tong Critical Cond. (Ft.) Length Guage Space Area

REMARK

BIT SUB WPO 26 4.1/2 REG NC 50 6.3/4 6.3/4 5.5/16 6.5/16 5/8 3/4

4.11/1 6 12.7/8 3.9/16 4.23/3 5.5/16 8.3/16 2

N/A N/A

ACC ACC

BOX x BOX CONNECTION

ACC ACC

3.80 FLOAT BORE

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

1 0 0 0 1

COMMENTS:

ACCEPTABLE AS AT THE TIME OF INSPECTION

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

SIMON OGBAN
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: SEADRILL

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: WEST POLARIS

LOCATION:
REPORT NO.

P.O.NO.
3016

W.O.NO.
DATE: 03/03/2012

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia. PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
SRG

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

Dia

Width

Conn. Length

ALL DIMENSIONS IN INCHES MPI on Length Tong Lead Critical Cond. (Ft.) Guage Space Area

REMARK

CROSS OVER SUB WPO 53 6.5/8 REG 8

7.17/3 7.29/3 2 11/16 6.1/16 2 5.5/16

N/A

23.7/1 7.5/8 REG 6 ACC

9.5/8

8.25/32

21/32

6.11/3 2 5.3/16

N/A 17.25/32 ACC

ACC 3.58

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

1 0 0 0 1

COMMENTS:

ACCEPTABLE AS AT THE TIME OF INSPECTION

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

SIMON OGBAN
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: SEADRILL

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: WEST POLARIS

LOCATION:
REPORT NO.

P.O.NO.
3017

W.O.NO.
DATE: 03/03/2012

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia. PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
SRG

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

Dia

Width

Conn. Length

ALL DIMENSIONS IN INCHES MPI on Length Tong Lead Critical Cond. (Ft.) Guage Space Area

REMARK

CROSS OVER SUB WPO 54 6.5/8 REG 8 7.9/16 11/16 6.1/16

7.29/3 2 5.5/16

N/A

22.15/ 7.5/8 REG 16 ACC

9.5/8

8.25/32

21/32

6.11/3 2 5.3/16

N/A 17.13/16 ACC

ACC 3.52

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

1 0 0 0 1

COMMENTS:

ACCEPTABLE AS AT THE TIME OF INSPECTION

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

SIMON OGBAN
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: SEADRILL

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: WEST POLARIS

LOCATION:
REPORT NO.

P.O.NO.
3018

W.O.NO.
DATE: 03/03/2012

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia. PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
SRG

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

Dia

Width

Conn. Length

ALL DIMENSIONS IN INCHES MPI on Length Tong Lead Critical Cond. (Ft.) Guage Space Area

REMARK

CROSS OVER SUB WPO 51 5.1/2 FH 7 6.3/4 21/32

5.15/1 6

N/A

N/A

N/A

24

ACC

7.5/8 REG

9.1/2

8.13/16

6.5/16

3/4

5.3/16

N/A

21.3/4

GT 3.99

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1 0 0 1

COMMENTS:

GALLED THREAD ON PIN CONNECTION

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

SIMON OGBAN
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: SEADRILL

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: WEST POLARIS

LOCATION:
REPORT NO.

P.O.NO.
3019

W.O.NO.
DATE: 03/03/2012

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia. PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
SRG

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

Dia

Width

Conn. Length

ALL DIMENSIONS IN INCHES MPI on Length Tong Lead Critical Cond. (Ft.) Guage Space Area

REMARK

CROSS OVER SUB WPO 39 5.1/2 FH 7

6.11/1 6

5/8

5.7/8

N/A

N/A

N/A

23.3/4 ACC

NC 50

6.3/4

2.3/4

6.13/32

11/16

4.23/3 2 4.5/16

N/A

21.3/16

ACC

ACC 3.76

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

1 0 0 0 1

COMMENTS:

ACCEPTABLE AS AT THE TIME OF INSPECTION

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

SIMON OGBAN
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: SEADRILL

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: WEST POLARIS

LOCATION:
REPORT NO.

P.O.NO.
3020

W.O.NO.
DATE: 03/03/2012

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia. PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
SRG

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

Dia

Width

Conn. Length

ALL DIMENSIONS IN INCHES MPI on Length Tong Lead Critical Cond. (Ft.) Guage Space Area

REMARK

CROSS OVER SUB WPO 101 6.5/8 FH 8.1/32

7.23/3 6.13/1 2 11/16 6

N/A

N/A

N/A

19

ACC

5.1/2 FH

6.13/16

2.13/16 6.23/32

N/A

N/A 5.21/32 N/A

19.3/8

ACC

ACC 3.31

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

1 0 0 0 1

COMMENTS:

ACCEPTABLE AS AT THE TIME OF INSPECTION

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

SIMON OGBAN
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: SEADRILL

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: WEST POLARIS

LOCATION:
REPORT NO.

P.O.NO.
3021

W.O.NO.
DATE: 08/03/2012

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia. PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
SRG

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

Dia

Width

Conn. Length

ALL DIMENSIONS IN INCHES MPI on Length Tong Lead Critical Cond. (Ft.) Guage Space Area

REMARK

CROSS OVER SUB WBO 44 6.5/8 REG 8

7.19/3 2

5/8

6.3/32 8.5/8

5.11/3 2

N/A

22.1/2 ACC

5.1/2 FH VAM EIS

3.3/4

6.11/16

N/A

N/A 5.11/16 N/A 22.11/16 ACC

ACC 3.87

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

1 0 0 0 1

COMMENTS:

ACCEPTABLE AS AT THE TIME OF INSPECTION

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

SIMON OGBAN
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: SEADRILL

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: WEST POLARIS

LOCATION:
REPORT NO.

P.O.NO.
3022

W.O.NO.
DATE: 08/03/2012

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia. PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
SRG

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

Dia

Width

Conn. Length

ALL DIMENSIONS IN INCHES MPI on Length Tong Lead Critical Cond. (Ft.) Guage Space Area

REMARK

CROSS OVER SUB WBO 85 6.5/8 REG 7 6.3/4 11/16 5.7/8 N/A N/A N/A

9.7/8

ACC

6.5/8 REG

2.27/32

7.1/2

5/8

5.7/16 5.9/16

N/A

4.15/16

ACC

ACC 3.63

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

1 0 0 0 1

COMMENTS:

ACCEPTABLE AS AT THE TIME OF INSPECTION

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

SIMON OGBAN
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: SEADRILL

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: WEST POLARIS

LOCATION:
REPORT NO.

P.O.NO.
3023

W.O.NO.
DATE: 08/03/2012

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia. PIN TOOL JOINT Lead Gauge Tong Space Cond. Conn. Type OD ID Bevel Dia.
SRG

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

Dia

Width

Conn. Length

ALL DIMENSIONS IN INCHES MPI on Length Tong Lead Critical Cond. (Ft.) Guage Space Area

REMARK

CROSS OVER SUB WPO 84 5.1/2 FH 7

6.11/1 6

5/8

5.15/1 6

N/A

N/A

N/A

9.29/3 6.5/8 REG 2 ACC

2.7/8

7.1/2

29/32

5.3/8

N/A

9.11/16

ACC

ACC 3.97

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

1 0 0 0 1

COMMENTS:

ACCEPTABLE AS AT THE TIME OF INSPECTION

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

SIMON OGBAN
ASNT LEVEL II

Member

You might also like