Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

2

NOTES

LINES
A

PIPING SYMBOLS

NOTES:-

GENERAL

LINES IDENTIFICATION PROCESS/UTILITY LINE BASKET STRAINER ELECTRICAL LINE INSTRUMENT GAS/ PNEUMATIC LINE ELECTRICAL TRACED LINE CHECK VALVE UNION VENDOR LIMIT LINE CENTER LINE INSULATION JOINT
L L L L

GATE VALVE

B
GLOBE VALVE

BURIED

FLAME ARRESTOR
1. HIGH POINT VENT AND LOW POINT DRAIN NOT SHOWN ON P&ID SHALL BE SHOWN ON PIPING ISOMETRIC / GENERAL ARRANGEMENT DRAWINGS .

ST

STEAM TRAP

ANGLE VALVE
2. ALL SAFETY VALVES DISCHARGE & EQUIPMENT DEPRESSURIZING LINES SHALL BE FREE DRAINING

CAPILLARY LINE

ANGLE BALL VALVE

TO VENT HEADER AND HAVE NO POCKETS UPTO AND INCLUDING HEADERS.

BUTTERFLY VALVE

ANGLE CHOKE VALVE

3. ALL ISOLATION VALVES IN TAPPINGS OF INSTRUMENTS (SUCH AS PRESSURE, LEVEL AND FLOW SWITCHES) CAUSING SHUTDOWN SHALL BE LOCKED OPEN.

HYDRAULIC LINE FUTURE

PLUG VALVE

ANGLE CONTROL VALVE

4. LINE NUMBERS SHALL BE INDICATED AS PER LINE LEGEND. 5. ALL INSTRUMENTS SHALL BE PROVIDED WITH ISOLATION VALVES FOR MAINTENANCE PURPOSE. IT SHOULD BE ENSURED THAT THESE VALVES SHALL BE EASILY ACCESSIBLE.

B
o o o

BALL VALVE SS TUBING (PROCESS) NEEDLE VALVE SCOPE OF WORK/LINE RATING CHANGE (WITH PIPING SPEC. DESIGNATION)

ADAPTER (TUBING PIPE)

THREE WAY VALVE

THREE WAY CONTROL VALVE FLOW ELEMENT ORIFICE/ RESTRICTION ORIFICE SPRING LOADED VALVE TURBINE METER DIAPHRAGM VALVE CONTINUOUS DRAIN

6. DRAINS OF LEVEL INSTRUMENTS (NON-SOUR SERVICES) SHALL BE PIPED TO NEAREST DECK DRAIN FUNNEL WITH 1/2" TUBE PIPE.

7. FOR PUMPS HANDLING SWEET LIQUID, CASING VENTS, DRAINS AND BASE PLATE DRAINS SHALL

VANES CONTROL VALVE

BE PIPED WITH VALVE TO NEAREST DECK DRAIN FUNNEL. CASING DRAINS AND VENT FOR PUMPS IN SOUR SERVICE SHALL BE PIPED TO CLOSED DRAIN HEADER RESPECTIVELY.

LOCALLY MOUNTED CONTROL VALVE LOCAL PURGED CONTROL VALVE WITH HAND WHEEL PANEL MOUNTED / CENTRAL CONTROL PANEL SELF ACTUATED PCV (DOWN STREAM)
C
S

POSITIVE DISPLACEMENT METER

HAND OPER. VANES VALVE


8. PROTECTION AGAINST GALVANIC CORROSION TO BE PROVIDED WHEREVER REQUIRED BETWEEN DISSIMILAR MATERIALS.

EXPANSION JOINT ROTAMETER

9. ALL VENT GAS PIPING SHALL BE FREE DRAINING WITH NO POCKETS.

SILENCER
10. ALL LIQUID SAMPLE POINTS EXCEPT FOR WELL FLUID SAMPLES SHALL BE TAKEN FROM CENTER OF

SONIC METER

JOHANUSMIRECFT

OPEN DECK DRAIN


THE PIPE. WELL FLUID SAMPLES SHALL BE TAKEN FROM VERTICAL PORTION OF THE PIPE. ALL GAS

(WITH LIQUID SEAL)


SAMPLES SHALL BE TAKEN FROM TOP OF THE PIPE.
M

LOCAL,PANEL MOUNTED SELF ACTUATED PCV (UP STREAM)

ELECTRIC MOTOR

SAMPLE POINT
11. INSTRUMENT ISOLATION VALVES SHALL BE AS PER DETAILS GIVEN BELOW. ALL VALVES SHALL

DIAPHRAGM SEAL BACK PANEL MOUNTED HAND OPERATED VALVE BACK LOCAL PANEL PISTON OPERATED VALVE COMPUTER FUNCTION
M

BE AS PER APPROPRIATE PIPING/INST. SPECS. DIAPHRAGM SEAL ALSO AS PER SPECS. ALL TAKE OFF CONNECTIONS SHALL BE SW (SOCKET WELD) UNLESS OTHERWISE SPEIFIED.

PILOT TUBE RTU VENTURI METER


INLET SIZE, INCHES ORIFICE CODE LETTER 203 24 OUTLET SIZE, INCHES SET PR, KG/CM2G

REMOTE TERMINAL UNIT


11.1 PI INSTR. PIPING 3/4" PI 1/2" INSTR. PIPING 1-1/2" 1/2" PI

DRAIN PLUGGED MOTOR OPERATED VALVE

PSV 101

(TYPICAL FOR PI,PT,PIC,PSH,PSL,PSHL) COMPUTER LOCAL PANEL SHUT DOWN VALVE DCS/DIDC BALL CONTROL VALVE FUNCTION BLOCK
D

DRAIN FLANGED RUPTURE DISC STRAIGHTENING VANE (FLANGED)


11.2

TAKE OFF CONNECTIONS- PIPING : 3/4", VESSELS : 1.5" FLANGED ALL DIAPHRAGM SEAL TYPE INSTR. TO HAVE 1.5" FLANGED TAPPING.

INSTR.
1/2"

PIPING

INSTR.

SCRAPPER TEE/SPHERE REE A ANALYSER


SP

INTERLOCK

BUTTERFLY CONTROL VALVE FILTER

SPECIALITY ITEM

3/4"
FLEXIBLE HOSE

LO

PI

3/4"

3/4"

PI

PI

PI

RUNNING LIGHT,LOCAL

PILOT VALVE (XPV) CAP (THREADED) RAIN CAP


11.3

3/4" LO

SLOPE(DOWN WARD) RUNNING LIGHT,PANEL HAMMER BLIND

PIPING

BLIND FLANGE RUNNING LIGHT,LOCAL PANEL SPECTACLE BLIND CAP (WELDED) SOLENOID VALVE(2 WAY) FLANGE

SHUT DOWN

INSTR.

1/2"

LO/LC REDUCER/EXPANDER HOSE CONNECTION

NORMALY LOCK OPEN INTERCHANGABLE TO LC

PDI

PDI

MANIFOLD(PER SPECS.) 1/2"

SOLENOID VALVE(3 WAY)

N2
E

NITROGRN CATRIDGE OFF/ON SKID OR SHOP FABRICATED

LC/LO

NORMALY LOCK CLOSE INTERCHANGABLE TO LO (TYPICAL FOR PDI,PDT,PDSH,PDSL,PDSHL) TAKE OF CONNECTION-PIPING : 3/4", VESSELS : 1.5" FLANGED ESD/FSD VALVES

POSITIVE CHOKE

SENIOR ORIFICE T-TYPE STRAINER

ADJUSTABLE CHOKE NC Y-TYPE STRAINER CONTROL VALVE W/POSITIONER FUSIBLE PLUG FOUR WAY VALVE NO NORMALLY OPEN NORMALY CLOSED

TS
QUICK EXHAUST VALVE

TEMPORARY STRAINER

1/2"

1/2"

28.02.06 DATE

ISSUED FOR BID

RVG BY

SG CHD APPR.

NO.

ISSUE

OIL AND NATURAL GAS CORPORATION LTD.


VORTEX FLOW METER
F

OFFSHORE DESIGN SECTION, E & C DIVISION MR, MUMBAI

PIPING & INSTRUMENTATION DIAGRAM (P&ID) FLOW SHEET & INSTRUMENT LEGEND

DEVELOPMENT OF C-SERIES STRUCTURE


DRAWING NO.-

7045-OD-1002

REV.

JOHANUSMIRECFT

You might also like