Anchor Recheck For Reverse Load
COMPUFIX 8.4
8.4.4581.17990/51/1862
Hilton Hotel & Residences Anchors for Top Bracket (Zone 4& 5, +WL)
Dimensions/loads:
dead loads variable loads (*) Not true to scale [mm], [kN], [kNm]
Tension load
Steel failure: Concrete cone failure: Pull-through / pull-out:
Used capacity
25.9 % 12.8 %
Result:
NOTE:
Hilton Hotel & Residences Anchors for Top Bracket, (Zone 4& 5, +WL) Anchor Bolt FAZ II 10 / 20
Page No 2 of print-out No 81
Max fixing thickness tfix Thread diameter M Setting torque MD Spanner A/F Hole diameter in the attachment df Anchorage depth hef Drill diameter d0 Minimum drill hole depth (through fixing) td
20 10 45 17 12 60 10 100
Hilton Hotel & Residences Anchors for Top Bracket, (Zone 4& 5, +WL) Anchor Bolt FAZ II 10 / 20