2. Roof Dead Load Ceiling (Including Joists & Furrings) (7/8" Wood Board) Roof Covering (Including Laps & Fastening) (24 U.S. Std Gage) Purlins LC 125x50x15x3.5 = 6.21 kg/m
354.00 Pa
140.00 Pa
60.92 N/m
3. Roof Live Load Flat to rise less than 3/8 slope 4. Additional Info Slope of Roof q Yield Strength of Steel, Fy Tributary length of purlins Span B. Load Analysis 1. Dead Load i. Properties for LC 125x50x15x3.5 3 3 Sx = 28.7 x 10 mm 3 3 Sy = 6.6 x 10 mm 3 4 Ix = 1793 x 10 mm 3 E = 200 x 10 MPa ii. Load from Ceiling + Covering Ceiling + Roof = 494.00 Pa 2. Wind Pressure P Outward 3. Live Load
1000.00 Pa
= = = =
296.4 N/m
-813.75 Pa
-488.25 N/m
Less than 1:3 slope 4. Load Summary Total Dead Load Total Live Load Total Wind Load
1000.00 Pa
600.00 N/m
= = =
Factored Gravity Load 0.75(1.4DL + 1.7LL) Factored Wind Load 0.75(1.7WL) C. Design of Purlin 1. Computing for Actual Stresses Normal Load from Gravity Wng = wcosq = 1129.09 N/m Normal Gravity Load Wind Load Wn = Wng Ww = 1129.09 + -622.52 Tangential Load Wt = wsinq
506.57 N/m
158.68 N/m
Moment along X and Y axes 2 Mx = WnL /8 = 1398.77 N-m 2 My = WtL /8 = 438.16 N-m Bending Stress along X and Y axes fbx = Mx/Sx = 48.74 MPa fby = My/Sy = 66.39 MPa 2. Computing for Allowable Stresses The section is a compact section with full lateral support. On strong axis: Fbx = 0.66Fy On weak axis: Fby = 0.75Fy
= 0.66 x 345
227.7 MPa
= 0.75 x 345
258.75 MPa
3. Check for Adequacy of Section Interaction Equation fbx fby + Fbx Fby 48.74 227.7 + 66.39 258.75
1.0
1.0 1.0
0.47061 <
Therefore section is safe for bending! Check for Deflection Wn = 1398.77 N-m
24.7837 mm
26.111 mm