So snh hiu qu s dng gia van cn bng c v van cn bng t ng


Th su, 06 Thng 11 2009 07:27 daivinh HVACR - iu ha khng kh trung tm

A - tt p v chi ph ca van (pressure drop and high cost of valves) I - Van cn b ng c - Tn tht p cao v chi ph mua van ln. Dng van cn bng c ti cc tng v cc nhnh cn lp thm cc loi van khc nn lm tn tht p cao v lm tng thm chi ph lp van b sung . Manual Balancing Valves need partner valves for riser, floor, and branches which required high pressure drop and high cost of valves.

II - Van cn b ng t ng - Tng tht p thp v chi ph mua van t


Thch 0 Chia lp van cn bng t ng s khng cn lp van cc loi van khc gia cc tng, ti cc tng v cc nhnh m ch cn lp van t ng ti cc unit cui do vy tn tht p l rt thp v 0 Tw eet 0 Khi s

gim c chi ph v van. Automatic Balancing Valves need no partner valves for riser, floor, and branches, only install the automatic balancing valves at the terminal units with the result of low pressure drop and Menu low cost of valves. B - Chi ph lao ng I - Van cn b ng c - Result of poor b alancing and high lab ors cost? Van cn bng c cn nhng cn b v cng nhn c k thut v kinh nghim iu chnh hoc cn bng hng trm chic van cn bng c trong h thng theo quy m ca b gin lnh FCU hoc AHU. Vic ny i hi tn rt nhiu nhn lc v rt kh c th cn bng mt cch chnh xc cc van. Manual Balancing Valves need skilled technician and reliable workman to adjust or balance hundreds of Manual Balancing Valves in the system according to capacity of Fan Coil or AHU which in reality rarely occurs with the result of poor balancing and high labors cost? II - Van cn b ng t ng - More accurate and reliab le Van cn bng t ng chnh xc v ng tin cy hn nhiu so vi van cn bng c li khng phi iu chnh do vy khng mt chi ph cn chnh van. Automatic Balancing Valves are more accurate and reliable without any adjusting or balancing cost. C - Chi ph vn hnh I - Van cn b ng c - Chi ph vn hnh cao mc cng sut ti a Vi s phc tp v rt kh iu chnh van cn bng c nn thng gy ra lu lng qu ti trong h thng ng dn t lm tng chi ph in nng cho bm nc lm lnh. With the complex and confused method of adjusting Manual Balancing Valves usually caused the overflow in circuits with high electricity cost at chilled water pump. II - Van cn b ng t ng - Chi ph vn hnh thp mc cng sut ti a Van cn bng hot ng mc lu lng c thit k ph hp do vy chi ph in nng cho bm nc lm lnh s mc ti thiu.

hvacr.vn/home/hvacr/dhkk-trung-tam/671-so-sanh-hieu-qua-su-dung-giua-van-can-bang-co-va-van-can-bang-tu-dong.html

1/2

19/02/2013

So snh hiu qu s dng gia van cn bng c v van cn bng t ng

Automatic Balancing Valves operated at proper designed flow with minimum electricity cost for chilled water pump. D - Hiu sut hot ng I - Van cn b ng c - Chi ph vn hnh cao khi khng s dng ht cng sut -High operating cost at partial load Khi mt phn h thng hot ng vi p sut cao hn s gy ra s vt qu lu lng phn cn li ang m ca h thng. When partial load higher pressure, causing re-overflow in remain opening circuits. II - Van cn b ng t ng - Chi ph vn hnh thp mc d hot ng khng ht cng sut - Low operating cost at partial load Nu hot ng ch mt phn cng sut s gy ra p sut trn h thng cao hn. Khi van cn bng t ng s t nh v cho ph hp vi lu lng thit k do chi ph tin in hot ng bm lm lnh s mc ti thiu. Higher system pressure occurs while partial load, Automatic Balancing Valves would re-position itself to the designed flow with minimum electricity cost for chilled water pump. E - Lu lng trong h thng ng dn I - Van cn b ng c - overflow to the circuits that might cause underflow to the other circuits Mt s nh thit k xem van cn bng l khng quan trng bi v vn c van kim sot nhit iu tit lu lng trong h thng ng dn. Nhng trong trng hp mt vi khu vc cng sut thit k thp hn cng sut thc t ( do iu kin thit k nh vt liu xy dng, thit b in hoc din tch ln hn d liu thit k) kt qu l nhit phng s lun cao hn ngng ci t do vy van kim sot nhit s vn lun m mi lc iu s gy ra s vt qu lu lng trong h thng ng. iu s gy ra hin tng nhng on ng khc s khng lu lng do vy s nh hng n cng sut ca h thng iu ha cc khu vc khc. Some designers consider balancing valves are not important because there still are temperature control valves to regulate the flow in the circuits. But in case of some areas where the designed load is less than the actual load, (due to the design condition such as construction material, electrical equipment, or occupation are more than the designed data) result of room temperature would always be higher than the set point, so temperature control valves would still open all the times causing overflow to the circuits that might cause underflow to the other circuits that effect the capability of air conditioning loading to the other areas. II - Van cn b ng t ng - Automatic Balancing Valves would always protect overflow Van cn bng t ng s lun m bo khng c hin tng lu lng vt qu trong trng hp bt k khu vc no m cng sut thit k thp hn cng sut thc t do vy s khng nh hng n cng sut ca h thng iu ha cc khu vc khc. Automatic Balancing Valves would always protect overflow in case of any areas where designed load is less than the actual load with no effect to the capability of air conditioning load at the other areas. NHNG U IM CA VAN CN BNG T NG T ng cn bng lu lng chnh xc cao hn ng tin cy hn Chi ph u t thp Chi ph vn hnh h thng thp Tit kim thi gian Linh hot c th b sung hoc loi b thit b u cui ( terminal units) m khng cn phi cn bng li h thng. Tit kim nng lng Tc gi daivinh Xem v tho lun v bi vit ti din n

Lin h ti Ban Qun l HVACR.VN qua a ch info@hvacr.vn khi pht hnh thng tin t Website ny. Ghi r ngun "WWW.HVACR.VN" v tc gi bi vit. Mi hnh vi sao chp m khng c s ng ca Ban Qun l HVACR.VN u l vi phm php lut. 2007 Bn quyn thuc v HVACR.VN - Cng ng K s C in Lnh Vit Nam.