Professional Documents
Culture Documents
RSLogix5000 V17 20080620
RSLogix5000 V17 20080620
00
Reporting
Controller Organizer Report
Usability Extensions
Forcing and Toggle Bit Added to Quick Watch Window Tag Monitor Enhancement - Alarm Grid Display Mode Search Item Browser Supports Tag Name Typeahead ControlFlash v7.0 Enhancements Coordinated System Time (CST) Master Existence Check On Download Tags Descriptions Length Extended Produced / Consumed Tag Status Verification Warning If Forces Are Present Verification Warning If AFI Are Present System Install Enhancements Start Page Enhancements Decorated Data Support in L5X Import/Export Files RSLogix 5000 Professional Concurrent RSLogix 5000 Standard Concurrent RSLogix 5000 Professional Changes Microsoft Windows Vista Support
Miscellaneouos
Motion Enhancements
Motion multi-axis programmable Jerk MCD and MCCD Motion Instructions Enhancements
RSI Integration
FactoryTalk AssetCentre Archive Check-In/Out RSLogix Architect Library Management
2
3/18/2013
Controller Support
ControlLogix 1756-L65 32MB Memory Controller GuardLogix 1756-L63S Controller CompactLogix 1769-L2x Controllers Removal of ControlLogix 1756-L55 and FlexLogix 1794-L34B Controller
Other
StratixTM Industrial Switch Portfolio CIP Sync support on 1756-EN2T Unicast Produced/Consumed Tags for EtherNet/IP Generic Modules CIP Generic Module COMM Format of None Cyclic EDT support for flex adapters (1794ACN, 1794-ACNR, 1794-AENT, 1797-ACNR)
Tools
Logix5000 Update Tool DELMIA Automation Bi-Directional Synchronization Utility
3/18/2013
3/18/2013
3/18/2013
3/18/2013
With V17, we are extending this functionality by allowing existing UDTs to be imported while maintaining existing members data values
Data values will be maintained when: Inserting/adding members Deleting members Rearranging (moving) members Renaming members Changing the data types of members Data values for members renamed and moved will not be maintained
Added member Added Member Added Member leaves existing data values unchanged
3/18/2013
Provide indication that changes have occurred and post mortem of where the changes are and by whom via the log Valuable for FDA regulated applications that need to know the applications has been modified
Change Change Log Counters
1
3/18/2013
...
SP
CC
...
ProgOper
Coordinated Control 0
CasRat 0 Auto 0 0 0
0.0 0.0 0.0
CV1EU CV2EU
0.0 0.0 0.0 CV3EU 0.0 SP 0 ProgOper 0 CV1Auto 0 CV2Auto 0 CV3Auto 0 0 0 0 CV1Override 0 CV2Override 0 CV3Override
SPProg 0.0 HandFB MMC_01 CV1Prog Manual 0 0.0 MMC ProgProgReq CV2Prog Override ... 0 0 CV3Prog ProgOperReq Hand Modular Multivariable Control 0 0 ProgProgReq ProgCasRatReq 0 PV1 CV1EU 0 ProgOperReq 0 PV2 CV2EU ProgAutoReq ProgCV1AutoReq 0 0 SP1Prog CV3EU ProgManualReq ProgCV2AutoReq 0SP2Prog 0 SP1 ProgOverrideReq ProgCV3AutoReq 0 0CV1Prog SP2 ProgHandReq ProgCV1ManualReq 0 CV2Prog ProgOper ProgCV2ManualReq 0 CV3Prog CV1Auto ProgCV3ManualReq 0 ProgProgReq CV2Auto ProgCV1OverrideReq 0 ProgOperReq CV3Auto ProgCV2OverrideReq 0 ProgCV1AutoReq ProgCV3OverrideReq CV1Manual
CVProg 0.0
3/18/2013
15
More Information
3/18/2013 Copyright 2008 Rockwell Automation Inc., All Rights Reserved 23
3/18/2013
27
3/18/2013
28
3/18/2013
37
Allows for extended descriptions or descriptions in multiple localized languages for the same tag
3/18/2013
39
3/18/2013
43
The RSLogix 5000 install validates the products serial # so that it can enable the correct Edition functionality while in Grace Period
An invalid serial # will set the RSLogix 5000 functionality equal to that of RSLogix 5000 Service Edition Note: the software will run as long as a valid activation is detected regardless of the correctness of the serial #
In v17, we have enhanced the warning dialog when an incorrect serial # is entered during install to better clarify this functionality and streamline the install process
3/18/2013 Copyright 2008 Rockwell Automation Inc., All Rights Reserved 47
3/18/2013
48
Replace xx" in the catalog number with the appropriate language designation: DE = German, EN = English, ES = Spanish, FR = French, IT = Italian, JP = Japanese, KO = Korean, PT = Portuguese, and ZH = Chinese
3/18/2013
49
Existing RSLinx Classic Professional and OEM customers under support will still be able to upgrade their software as needed
3/18/2013
50
It is uncertain at this time if there are any issues that need to be addressed that would prevent earlier RSLogix versions from operating on Vista
If changes to RSLogix 5000 are required, we will have to review them on a case by case basis to determine how to deal with previous releases (V13 thru 16)
A Vista compatible version of RSLinx Classic will also be released in conjunction with RSLogix 5000 V17
However, drivers for ISA bus communication cards will be removed from this version
3/18/2013
51
3/18/2013
52
Applies to all Logix5000 platforms Allows system expansion without having to shutdown controller and/or network Very important for process applications
3/18/2013
62
PowerFlex 4-Class Multi-Drive PowerFlex 7000-2 New wizards: PowerFlex 755 Startup Add I/O online EtherNet/IP ControlNet
Requires 20-COMM-C/-Q (v2.007) and 22-COMM-C (v1.005) firmware modification to allow control via unscheduled messaging
RSLinx path splicing Automatically provides the PC-to-Drive RSLinx path so the user does not have to find the drive in a Who window to perform an upload / download
63
Supported with V17 firmware Targeted to be available in conjunction with v17 release
Initially limited to non-redundant systems till V17.5x redundancy release is available
3/18/2013
64
Programmatic GSV access to Safety Signature Targeted to be available in conjunction with V17 release
More Information
3/18/2013 Copyright 2008 Rockwell Automation Inc., All Rights Reserved 65
CompactLogix 1769-L23
Expands Logix technology to the smaller applications High functionality in a small package Packaged to lower acquisition cost and simpler configuration Available EtherNet/IP integrated ports for world class connectivity Embedded I/O is pre-configured in RSLogix 5000 for ease of use Expandable, with 2 local I/O cards and networked I/O Ideal for Logix users in need of lower price controller for small applications Support of advanced IA features like Alarms and Events, Drives Premier Integration or Phase Manager Database integration with FactoryTalk View and PanelView Plus.
3/18/2013 Copyright 2008 Rockwell Automation Inc., All Rights Reserved 70
The new Logix packaged controller for smaller Integrated Architecture implementations
3/18/2013 Copyright 2008 Rockwell Automation Inc., All Rights Reserved 71
Cat. Number Embedded Communication Ports EtherNet/IP Connections Memory Embedded I/O (pre-configured in Logix 5000) Expansion Project Structure
1769-L23E-QB1B
Isolated Serial EtherNet/IP with (MSG + I/O)
1769-L23-QBFC1B
Isolated Serial Non-Isolated Serial
1769-L23E-QBFC1B
Isolated Serial EtherNet/IP with (MSG + I/O)
8 TCP/IP 32 CIP
n/a
8 TCP/IP 32 CIP
512 KB 16 DC in, 16 DC out, 4 Analog in, 2 Analog out. 4 High speed counters (250KHz)
512 KB 16 DC in, 16 DC out, 4 Analog in, 2 Analog out. 4 High speed counters (250KHz)
2 Additional 1769 I/O modules OR 1 1769 Comm Module 3 Tasks Continuous, Periodic or Event All (LD, FBD, ST and SFC) Same as L31 Same as L31
2 Additional 1769 I/O modules OR 1 1769 Comm Module 3 Tasks Continuous, Periodic or Event All (LD, FBD, ST and SFC) Same as L31 Same as L31
2 Additional 1769 I/O modules OR 1 1769 Comm Module 3 Tasks Continuous, Periodic or Event
3/18/2013
73
Removal of ControlLogix L55 and FlexLogix L34 Controllers from RSLogix 5000 V17
These controllers are in Silver Series designation effective December 31, 2007 with a last-time-buy deadline of December 31, 2008
See additional information on: http://www.ab.com/silver/controllogix.html and http://www.ab.com/silver/flexlogix.html
The last version of firmware for the L55 and L34 controllers was V16
With V17, the firmware would no longer fit within the L34 and L55 controllers With Logix most of the firmware content is shared across all controllers The firmware grows in sized with each release as new functionality is added The ControlLogix 1756-L55 controller was initially released with V7 in Dec 15, 2000 The FlexLogix 1794-L34 controller was initially released with V6 Aug 31, 2000
The L55 and L34 can continue to operate with newer controllers
Communications via messaging and Produced / Consumed Tags RSLogix 5000 Side-by-side install / Multiple Revision Support permits continued access and maintenance
3/18/2013 Copyright 2008 Rockwell Automation Inc., All Rights Reserved 74
Provides common time reference for the ControlLogix Architecture over UNMODIFIED standard Ethernet hardware to 100nanoseconds Multi-Master time network self arbitrates for best time source Wide application base
Simplified Controller Clock Setting Alarms and Events Coordinated outputs SOE First Fault Detection History Logging to DB for event re-creation and simulation Global System Motion Registration
3/18/2013
Time Sync Object
PTP Clock
76
Logix5000 Controllers Supported Ladder Diagram Function Block Diagram1 9324-RLDFBDENE Sequential Function Chart1 & 8 9324-RLDSFCE Structured Text1 9324-RLDSTXE Safety1 & 6 9324-RLDGLXE PhaseManager1 & 5 9324-RLDPME Emulate 5000 9310-WED200ENE PIDE Autotune 9323-ATUNEENE
View Only
Separate Option
Included
Separate Option
Included4
Included4
View Only View Only View Only Separate Option Separate Option
Separate Option Separate Option Separate Option Separate Option Separate Option
1. Able to upload and download without option. Must purchase option to view, edit and print routines in this language 2. Full Edition supports controllers running V10 and higher 3. Service Edition supports controllers running V12 and higher 4. Must be installed on same PC as RSLogix 5000 5. PhaseManager supported in V15 and higher
6. 7. 8.
Standard Task functionality remains the same PIDE Autotune supported V16 and higher Requires Structured Text option to program ST assignments in SFC actions
3/18/2013
83
1. 2. 3.
Able to upload and download without option. Must purchase option to view, edit and print routines in this language Full Edition supports controllers running V10 and higher Service Edition supports controllers running V12 and higher
4. 5. 6. 7. 8.
Must be installed on same PC as RSLogix 5000 PhaseManager supported in V15 and higher Standard Task functionality remains the same Motion supported in V16 and higher Software is designed to grab highest functionality license first I.e.; if Standard, Full and Professional Concurrent licenses are available on the FT Activation server, RSLogix 5000 will grab highest functionality license first 84
3/18/2013
Questions?