1. Remove ABIS from SUMA 2. Power ON the switches in the BTS cabinet 3. Load software: Master: BM1SAQ97.MSF/ CPF: 0002AQFS.DDL/ CODA: coda.990 4. Sector mapping 5. BTS initialization of all sector 6. Performing BTS inventory 7. Check VSWR of all the ANX (ANTENNA) 8. Perform Fan test 9. Perform ABIS loop test 10. Frame setting 11. Board setting 12. Initial setting 13. Setting and checking the External alarm 14. Invent file and save IR 15. End Commissioning 16. Switch off the BTS 17. Connect ABIS 18. Power ON the BTS 19. Call OMC-R to load the site 20. Confirm from OMC-R the site is ON AIR 21. Ensure the sectors are taking traffic 22. Check the handovers and leave the site