ABNORMAL PARAMETERS
DURING START
If ITT tends to exceed 900C, or no ITT, or no NH
CL affected side ................................................................ FUEL SO
ENG START ROTARY SELECTOR..............OFF / START ABORT
PEC FAULT
If in short final approach (below 400 ft RA)
GO AROUND procedure..............................................APPLY
FLAPS UNLK
If before V1
TAKE OFF........................................................ABORT
If after V1
VR, V2............................................INCREASE BY 10 KT
If alarm occurs during approach
GO AROUND procedure..................................APPLY
VGA................................................INCREASE BY 10 KT
ELEVATOR JAM
CONTROL COLUMNS................................UNCOUPLE
EFIS COMP
If ROL, PIT, ATT, HDG cautions appears on EFIS
BOTH EADI, STBY HORIZON...................................CROSS CHECK
WRONG INSTRUMENT..........................................IDENTIFY