8. Set the RF-IF CONTROL to AM.

OUTPUT control for the same reading on the


DIGITAL READOUT as was noted in Step g.
9. Depress the SiN CHECK button and note the
reading of the DIGITAL READOUT. Note the setting of the MICROVOLTS OUTPUT con-
trols. This setting is the 10 dB (S+N)/N sensitivity
With the S/N CHECK button in the "out" posi- point. The test should be repeated on the USB.
tion, set the RF-IF CONTROL switch to the The sideband giving the highest reading is the rated
LSB position.and re-adjust the MICROVOLTS receiver sensitivity.

SSBADJACENTSIDEBANDREJECTION

l-l t-f l-l I t-t t-l


| | t_t t_t I.Lt t_l

S =I\C)OF== OELUXECB ANALYZER

WATTS

RF.IF GENERATOR D I G I T A T R E A O O U TS E L E C T O R
a a
'lAN.
^ r

,-.,r@: l9';'slq,v4r.Is

SPEAKER SUB
4n 8 n
SPtA(tB.^.160
iLo'P"wl'"I:,/t^\

SIGNALS MOOEL
I
D I G I T A L R E A D O U TI N P U T S I G I U A L S
ca42 sPtA(tnsu8
otf 0i/

Fig. 4}-Control setup /or SSB adiacent sideband reiection test.

The adjacent sideband rejection of a receiver indicates 4. Set clarifier by performing General SSB Receiver
how well the receiver'sIF stageswill reject a signal on Test.
the sideband opposite the one desired. For example:
If the receiver is set for USB on channel 4, the figure o. Set the MICROVOLTS OUTPUT controls to the
indicates how well the receiver will reject a LSB signal receiver'srated 10 dB sensitivity point.
on channel 4.
6. Set the DIGITAL READOUT SELECTOR to
To test for adjacent sidebandrejection: the AUDIO WATTS position.

l-. Supply the proper power to the CB receiver. 7. Set the RF-IF CONTROL switch to the LSB
position.
2. Connect the output of the CB42's RF-IF OUT-
PUT jack to the antenna input of the receiver 8. Set the receiver's volume control for a reading of
using the supplied RF cable. 1.00 on the DIGITAL READOUT.
3. Connect the receiver audio output to the 9. Set the receiver's function switch to USB.
SPEAKER SUB input jack using the supplied
audio cable. Set the SPEAKER SUB control for 1 0 . Increase the setting of the MICROVOLTS OUT-
the same impedance as the output of the PUT controls for a reading of 1.00 on the
receiver. DIGITAL READOUT.

37