condition

all 4 operating
1st is cut
2nd cut
3rd cut
4th cut
Total

rpm

load

2205
2200
2200
2200
2200

bp (KW)

23.8
14.6
13.3
13.6
14

IP(KW) of
each
cylinder(s)

FP

indicated
mechanical
power(kW) eff.
in each case

5.573854
9.327037 3.753183
9.327037
3.411501 2.1623524 3.753183 7.1646845
3.107738 2.46611623 3.753183 6.86092067
3.177837 2.39601688 3.753183 6.93102001
3.271303 2.30255109 3.753183 7.02448581
9.3270366

0.59760178
0.47615516
0.45296219
0.45849485
0.46569997