Download as pps, pdf, or txt
Download as pps, pdf, or txt
You are on page 1of 43

RAD International Technical Seminar

May 2007

Abis & Ater Optimization

Presented by: CBNetworks Technical Support support.technique@cbnetworks.fr http://www.cbnetworks.fr

Agenda
Background Vmux-400/420 features How does it work? Vmux-4.xx Configurator Tool Statistics

Interoperability
Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 2

Optimization Market Needs


Market potential: 1 Billion potential cellular subscribers in GSM rural areas (Nokia Chairman) Cellular backhaul relies on leased lines, private networks and satellite connections Backhaul costs reach 40-60% of the operators OpEx 2.5G / 3G services and mobile users increase incurs additional network investments (optimized 2G leased lines can be transferred to 3G networks)

Connectivity optimization reduces costs

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 3

GSM Network Architecture


Interface: Solution: E(PCM) Vmux-2100/ Gmux-2000 A(PCM) / Ater* Vmux-2100 / 420* Abis Vmux-400/420

BSC
BTS

BTS

PSTN
MSC BSC
BTS BTS

MSC

BTS

BSC
BTS BTS

HLR

BTS

VLR
BTS

*Depends on the GSM Transcoder location: - if located at MSC Ater (Vmux-420) - if located at BSC A Interface (Vmux-2100/Gmux-2000)

BTS Base Transceiver Station MSC Mobile Switching Centre


http://www.cbnetworks.fr - support.technique@cbnetworks.fr

BSC Base Station Controller

(= BSS)

HLR & VLR Home & Visitor Location Registers


Abis & Ater Gateway TS-2007 Slide 4

Optimization and not Compression


BSC

Ater

Abis

Optimized data
BTS

ABIS/ ATER contains: 1. Compressed voice 2. Idle channels 3. Silence within active calls 4. Signaling + headers [ = overhead] 5. Data (such as GPRS / EDGE)
http://www.cbnetworks.fr - support.technique@cbnetworks.fr
Abis & Ater Gateway TS-2007 Slide 5

Agenda
Background
Vmux-400/420 features How does it work? Vmux-4.xx Configurator Tool Statistics

Interoperability
Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 6

Vmux-400 Features
Average Optimization: Up to 3:1 (fractional uplink) User Input: 1 or 2xE1/T1 (ordering option) Uplink Interfaces: E1/T1, ETH/IP, Serial (all built-in) Clocking: Clock is transferred even when using ETH/IP uplink Power Options: AC/DC

Data compression: (NEW)


Compresses ~ 10% - 15% more during peak hours (License is needed) Point to Multipoint (using bundles)

Voice CODECs
Interoperability with all Major vendors Tools, such as Bandwidth Calculator, Configurator
http://www.cbnetworks.fr - support.technique@cbnetworks.fr
Abis & Ater Gateway TS-2007 Slide 7

Vmux-420 (Beta) Features


All Vmux-400 features (except Serial Uplink & T1) User Input: Up to 12xE1 (4, 8, or 12 - ordering option) Uplink Interfaces: Up to 6xE1 or ETH/IP (all built-in) Chassis: 1U, 19 wide Redundancy: full redundancy (Carrier Class Product) Dry Contact Alarm Relay

TDM trunks aggregation (grooming)


Interoperability between Vmux-400 and Vmux-420

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 8

Vmux-420 Back Panel

2 Fully redundant Main Modules, in case of H.W malfunction


All ports connected to both Main Modules, supplying FULL redundancy

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 9

Vmux-400/420 Management
User terminal Telnet RV-LITE + SNMP traps

ConfiguRAD

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 10

Agenda
Background Vmux-400/420 features How does it work? Vmux-4.xx Configurator Tool

Statistics
Interoperability Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 11

Operation
Optimization process
1. Suppress Idle channels

2.
3.

Suppress traffic when there are Silence frames within active calls*
Remove Signaling HDLC flags (only valid signaling is transferred) Suppress signaling FISU & LSSU (ATER segment only)

Vmux-400/420

FROM BSC (MSC)


Optimization

Vmux-400/420

Optimized Data

ABIS (/ ATER) Compressed Voice

BTS (/BSC)

(* when DTX mode is active in the GSM network)


http://www.cbnetworks.fr - support.technique@cbnetworks.fr
Abis & Ater Gateway TS-2007 Slide 12

Data Compression
How does it works?

- The data compression unit accumulates information coming from the optimization unit and compresses it. The information is compressed similar to Zip a file in PC
Performance - Saves about 10 - 15% bandwidth during peak hours. - Higher performance when there is more Data traffic (GPRS / EDGE - up to 50%) - There are 2 compression levels: Normal level and High level. Why Data? - The output from the optimization unit contains data and not voice - This is non-destructive compression. Tradeoff for High Packet loss level - Sensitive to packet loss therefore it is only good for networks with low packet loss. License dependant
Vmux-400/420 Vmux-400/420
ABIS / ATER Compressed Voice

Optimized + Compressed Data

BTS Optimization Data Compression


Abis & Ater Gateway TS-2007 Slide 13

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Traffic Types Supported VOICE


Voice Codecs: FR (Full Rate)

EFR (Enhanced Full Rate)


AMR (Adaptive Multi-Rate) HR (Half Rate)
Up to 24 timeslots Per Vmux-400 *

AMR-HR

Vmux-400/420 can automatically detect the GSM sub-channel rate (16kbps or 8kbps)

* Current H.W. limitation (there is no limitation for the Vmux-420)


http://www.cbnetworks.fr - support.technique@cbnetworks.fr
Abis & Ater Gateway TS-2007 Slide 14

Traffic Types Supported DATA


SMS / WAP: Transferred as part of the signaling channel.

GPRS: CS* 1,2,3 and 4 transported over timeslots configured for TRAU traffic => BTS can use any TRAU timeslot to transmit GPRS

EDGE:
Transported over timeslots configured for TRANSPARENT. BTS must use a predefined set of timeslots for EDGE services

*CS = Code Scheme


http://www.cbnetworks.fr - support.technique@cbnetworks.fr
Abis & Ater Gateway TS-2007 Slide 15

Clocking over TDM/IP Link


RCV (Uplink) Vmux-400 ADAPTIVE = ENABLE TDM\IP Network

RCV (Ingress)
Vmux-400/420 ADAPTIVE = ENABLE

For IP uplink

For IP uplink

BTS

BSC

(LBT)

(Clk Source)

Clock transferred from BSC to BTS over any transmission network (Adaptive clock recovery mechanism enables to transfer the clock over ETH/IP unique feature!)

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 16

Clocking over Satellite IP Link


Internal
Vmux-400/OCXO ADAPTIVE = DISABLE

RCV (Ingress)
Vmux-400/420

IP network

ADAPTIVE = DISABLE

BTS

BSC

(LBT)

(Clk Source)

OCXO* (ordering option) for highly accurate internal oscillator operating at 2.048Mhz 0.5 ppm (use when IP network jitter is higher than 50 msec)

* Only needed on the BTS side


http://www.cbnetworks.fr - support.technique@cbnetworks.fr
Abis & Ater Gateway TS-2007 Slide 17

Signaling Rate Detection


Signaling Rate Detection Vmux-400/420 can automatically detect the data rate of the signaling channels (16, 32 or 64Kbps)

Before Vmux- 400/420 detects


signaling channels rate
Ts# Type Byte Reversal Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Bundle#

After Vmux- 400/420 detects


signaling channels rate
Ts# Type Byte Reversal Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Bundle#

| v

1 2 3 4 5 6 7 8 9 10

Dynamic Dynamic Dynamic Dynamic Dynamic Dynamic Dynamic Dynamic Dynamic Dynamic

1 1 1 1 1 1 1 1 1 1

| v

1 2 3 4 5 6 7 8 9 10

Sig64 Sig64 Sig64 Dynamic Dynamic Dynamic Dynamic Dynamic Dynamic Dynamic

1 1 1 1 1 1 1 1 1 1

Available Time Slot Types: All set to Dynamic TRAU: GSM Speech Sig64/Sig32/Sig16: HDLC Signaling, 64/32/16 kbps Trp64/Trp32/Trp16: Transparent data, 64/32/16 kbps
http://www.cbnetworks.fr - support.technique@cbnetworks.fr
Abis & Ater Gateway TS-2007 Slide 18

Timeslot Type Detection (Ericsson)


Timeslot Type Detection (Ericsson) After reboot, the Ericsson BSS changes timeslot assignment for speech and signaling. To support this Vmux-400/420 can automatically detect the timeslot type (speech or signaling). After Vmux-400/420 detects timeslots type
Ts# Type Byte Reversal Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Bundle#

Before Vmux-400/420 detects timeslots type


Ts# Type Byte Reversal Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Bundle#

| v

1 2 3 4 5 6 7 8 9 10

Dynamic Dynamic Dynamic Dynamic Dynamic Dynamic Dynamic Dynamic Dynamic Dynamic

1 1 1 1 1 1 1 1 1 1

| v

1 2 3 4 5 6 7 8 9 10

Sig64 Sig64 Sig64 TRAU TRAU TRAU TRAU TRAU Dynamic Dynamic

1 1 1 1 1 1 1 1 1 1

Available Time Slot Types: All set to Dynamic

TRAU: GSM Speech


Sig64/Sig32/Sig16: HDLC Signaling, 64/32/16 kbps Trp64/Trp32/Trp16: Transparent data, 64/32/16 kbps

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 19

Agenda
Background
Vmux-400/420 features How does it work? Vmux-4.xx Configurator Tool Statistics

Interoperability
Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 20

Vmux-4.xx Configurator Tool: Step 1


1. Site survey
Configuration Bandwidth estimation Configuration Tool

1. Site survey
Collecting information from the mobile operator: - GSM segment: ATER/ ABIS - Vendor - Uplink type: TDM / IP - Timeslot assignment - Downstream DTX (y/n) - Clock transfer

2. 3.

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 21

Vmux-4.xx Configurator Tool: Step 2


1. Site survey
Configuration Bandwidth estimation Configuration Tool

2. Configuration parameters
Configure device according to the information we got from the survey.

2. 3.

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 22

EXAMPLE: Alcatel Time Slot Configuration


BSC/BTS Configuration:
(6 x TRX, 48 GSM speech channels)
1.
2. 3.

Site survey
Configuration Bandwidth estimation Configuration Tool

Vmux-400 Time Slot Table:


Display Time Slots Configuration Ts# 1 2 | 3 v 4 5 6 7 8 9 10 Type -Sig64 TRAU TRAU Sig16 TRAU TRAU TRAU TRAU TRAU Byte Reversal Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Bundle# 1 1 1 1 1 1 1 1 1 1

Available Time Slot Types: TRAU: GSM Speech Sig64/Sig32/Sig16: HDLC Signaling, 64/32/16 kbps

Trp64/Trp32/Trp16: Transparent data, 64/32/16 kbps


http://www.cbnetworks.fr - support.technique@cbnetworks.fr
Abis & Ater Gateway TS-2007 Slide 23

Vmux-4.xx Configurator Tool: Step 3


1. Site survey
Configuration Bandwidth estimation Configuration Tool

3. Bandwidth considerations
Bandwidth is influenced by the following parameters: Fixed - Timeslot assignment - Uplink type (IP or TDM) - Using Downstream DTX. Estimated - Estimated silence within calls - Estimated idle channels

2. 3.

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 24

Vmux-4.xx Configurator Tool:


1. Site survey
Configuration Bandwidth estimation Configuration Tool

Vmux-400/420 Configuration tool

2. 3.

Vmux-400 Configuration guide

Try it in workshop

Available at: http://www.cbnetworks.fr/ftp/rad/outils/ InfoCenter Technical Resources


http://www.cbnetworks.fr - support.technique@cbnetworks.fr
Abis & Ater Gateway TS-2007 Slide 25

Agenda
Background
Vmux-400/420 features How does it work? Vmux-4.xx Configurator Tool Statistics

Interoperability
Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 26

Statistics
Uplink statistics: TDM/Serial/Ethernet uplink: Evaluate bandwidth on uplink Signaling statistics: Verify signaling channels are up TRAU statistics: TRAU traffic analyzing Bandwidth control statistics: Display calls stopped or discarded BW utilization statistics: Display enhanced information

on bandwidth consumption

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 27

Agenda
Background Vmux-400/420 features How does it work?

Vmux-4.xx Configurator Tool


Statistics Interoperability Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 28

Vmux-400 Interoperability
Interoperable with all major vendors:

Ericsson, Siemens, Nokia, AlcatelLucent, Huawei, Motorola, Nortel,

Vmux-400/420

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 29

Agenda
Background Vmux-400/420 features How does it work?

Vmux-4.xx Configurator Tool


Statistics
Interoperability Applications

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 30

GSM Service to Remote / Rural Regions


Remote Site

Central Office
ETH/IP

ETH/ Vmux-400 IP E1

MSC
E1s

BSC
E1

BTS

Vmux-400 Hub Transceivers


E1

Remote Site

Vmux-400
ETH/ Vmux-400 IP E1

Central site solution is needed

BTS

Connection via satellite, microwave, terrestrial links, flexible interfacing (IP/ETH/SERIAL/E1) Effective solution where the cellular operator pays for expensive transmission links
http://www.cbnetworks.fr - support.technique@cbnetworks.fr
Abis & Ater Gateway TS-2007 Slide 31

GSM Service to Remote / Rural Regions


Remote Site

Central Office

ETH/ Vmux-400 IP E1

MSC
E1s

BSC

Vmux-420
Hub Transceivers

BTS

Remote Site

Up to 12 E1

ETH/IP

ETH/ Vmux-400 IP E1

BTS

Connection via satellite, microwave, terrestrial links, flexible interfacing (IP/ETH/SERIAL/E1) Effective solution where the cellular operator pays for expensive transmission links
http://www.cbnetworks.fr - support.technique@cbnetworks.fr
Abis & Ater Gateway TS-2007 Slide 32

Summary

RAD offers a full MSC-BSC-BTS cellular backhaul solution

Cost effective voice optimization solution for central and remote sites Up to 3:1 optimization of Abis/ Ater interface

Up to 10% - 15% saving with Data Compression


Connects over any uplink Interoperable with all major vendors

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 33

thank you
for your attention
Technical Support support.technique@cbnetworks.fr http://www.cbnetworks.fr
http://www.cbnetworks.fr - support.technique@cbnetworks.fr
Abis & Ater Gateway TS-2007 Slide 34

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 35

Vmux-400 Ports

Control Port E1 Uplink (Egress/Output) to network Serial Uplink (Egress/Output) to network

ETH Management

User E1 Ports* (Ingress/Input) from BTS/BSC/MSC

ETH/IP Uplink (Egress/Output) to network

* Ordering Options: 1 or 2 ingress E1 ports


http://www.cbnetworks.fr - support.technique@cbnetworks.fr
Abis & Ater Gateway TS-2007 Slide 36

Vmux-420 Ports

Up to 12 User E1 Ports* (Ingress/Input) from BTS/BSC/MSC

Up to 6 E1 Uplink (Egress/Output) to network ETH/IP Uplink (Egress/Output) to network

Control Port ETH Management port

2 Redundant Power supplies

Alarm Relay

* Ordering Options:

- 4,8 or 12 Ingress E1 ports - 2,4 or 6 Egress E1 ports


Abis & Ater Gateway TS-2007 Slide 37

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

GSM Subchannel Rate Detection


GSM Subchannel Rate Detection Full Rate (FR): Each voice channel is carried in a 16 kbps sub channel Half Rate (HR): Each voice channel is carried in a 8 kbps sub channel Vmux-400/420 can automatically detect the GSM subchannel rate (16 kbps or 8 kbps)

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 38

Ericsson Time Slot Configuration


BSC/BTS Configuration:
(10.5 x TRX, 84 GSM speech channels)
CH 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Sub Channel CONC MPLEX16 MPLEX16 MPLEX16 MPLEX16 UNDEF MPLEX16 MPLEX16 UNDEF UNDEF UNDEF UNDEF UNDEF MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 CONC UNDEF UNDEF MPLEX16 MPLEX16 UNDEF UNDEF UNDEF UNDEF MPLEX16 MPLEX16 CONC MPLEX16 MPLEX16 Content TRXC SIGNAL SPEECH/DATA SPEECH/DATA IDLE SPEECH/DATA IDLE IDLE IDLE IDLE IDLE SPEECH/DATA SPEECH/DATA SPEECH/DATA SPEECH/DATA SPEECH/DATA SPEECH/DATA SPEECH/DATA SPEECH/DATA SPEECH/DATA SPEECH/DATA TRXC SIGNAL IDLE IDLE SPEECH/DATA IDLE IDLE IDLE IDLE SPEECH/DATA CF/TRXC SIGNAL SPEECH/DATA

MPLEX16 MPLEX16 MPLEX16

MPLEX16 MPLEX16 MPLEX16

How to configure Vmux-4.xx according to the timeslots table? TS1, 21, 30 : Sig64

TS2, 3, 5, 11-20, 24, 29, 31 : TRAU

TS4, 6-10, 22-23, 25-28:

: N/C.

MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16

MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16 MPLEX16

MPLEX16

MPLEX16

Available Time Slot Types: TRAU: GSM Speech

Sig64/Sig32/Sig16: HDLC Signaling, 64/32/16 kbps


Trp64/Trp32/Trp16: Transparent data, 64/32/16 kbps

MPLEX16 MPLEX16

MPLEX16 MPLEX16

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 39

Statistics: BW Utilization Statistics


Vmux400 / BSC
Display Total Accumulated

ALRM
Number of seconds accumulated for each bandwidth range

< 64

Kbps] Kbps] Kbps] Kbps] Kbps] Kbps] Kbps] Kbps] Kbps] Kbps] Kbps]

... (236024) ... (5) ... (314) ... (1203) ... (3455) ... (14563) ... (21003) ... (13900) ... (4231) ... (911) ... (43)

[704 -767 [768 -831 [832 -895 [896 -959

Kbps] Kbps] Kbps] Kbps]

... (44) ... (354) ... (233) ... (23) ... (4) ... (0) ... (0) ... (4) ... (0) ... (0) ... (0)

[ 64 -127 [128 -191 [192 -255 [256 -319 [320 -383 [384 -447 [448 -511 [512 -575 [576 -639 [640 -703 ... (N) >

[960 -1023 Kbps] [1024-1087 Kbps] [1088-1151 Kbps] [1152-1215 Kbps] [1216-1279 Kbps] [1280-1343 Kbps] [1344-1407 Kbps]

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 40

Mobile Platforms

MSC
E1s

BSC

Vmux-400
E1

Serial/ IP/E1

Vmux-400
Serial/IP/E1 E1

BTS

Supply service to mobile platforms such as cruise ships

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 41

Mobile Platforms

MSC
E1s

BSC

Vmux-400
E1

Serial/ IP/E1

Vmux-400
Serial/IP/E1 E1

BTS

Supply service in large and crowded events using trucks

http://www.cbnetworks.fr - support.technique@cbnetworks.fr

Abis & Ater Gateway TS-2007 Slide 42

Terrestrial Daisy Chained BTSs

FE1

BTS
FE1

BTS MSC
E1s

BSC
E1

Vmux-400 / 420

Vmux-400

TDM or IP
DXC

E1 E1 FE1

BTS

FE1 FE1

BTS BTS BTS

Requires Drop & Insert capability at the BTS


Suitable when each BTS serves a small area
http://www.cbnetworks.fr - support.technique@cbnetworks.fr
Abis & Ater Gateway TS-2007 Slide 43

You might also like