For panels DE, a = 5650mm. For a 2 h,,, the compressibe axial force Pro is given by:
BS EN 1993-1-5 C 1 NA.2.7
orbd
= 0 for
L = kzor
q r = k Z o b=5.84x10.7=62.4Nlmmz
=1440-(0.8x62.4x2000x15x10") =-96.7kN
:.Take Pro = 0.
The total compressive ,force to he resisted is therefore 925 + 0 = 925 k N Buckling resistance of the stiffener (as above) NI,,Hd = 1881 k N > 925 kN