Rack de Tuberia Rack de Tuberia: 3400-15R-701 0T 240K-C2-1:250

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

100m

A
D

K
2'

50m

1'

3'

4'

5'

6'

7'

1:1000

5.1
50m

40m

C
5'

3420 REGRIND EMERGENCY OVERFLOW SUMP 3420 SUMIDERO DE EMERGENCIA PARA REBALSE DE REMOLIENDA 3430 REGRIND COLUMN CELL 3430 CELDA COLUMNA DE REMOLIENDA 3420 REGRIND BUILDING 3420 EDIFICIO DE REMOLIENDA

30m

20m

3
10m 0 0

1' 0 1' 2' 3' 4' 5' 10' 15'

2'

3'

4'

10' 0 5' 10' 15' 20' 30'

PIPERACK 240K-C2-3400-15R-707 RACK DE TUBERIA

PIPERACK 240K-C2-3400-15R-708 RACK DE TUBERIA

5.2

1:500

20m

240K-C2-3400-15R-702
1

240K-C2-3400-15R-703

240K-C2-3400-15R-704

240K-C2-3400-15R-705

15m

N 8,167,907.033 E 223,715.588

5m

10m

1:200

5m

ISSUED FOR DETAILED ENGINEERING PHASE EMITIDO PARA INENIERIA DE DETALLE

ENGLISH LANGUAGE SHALL GOVERN. LA LENGUA INGLESA TENDRA PRECEDENCIA

REV.
0

DATE

REVISION DESCRIPTION

DES. CHK.
GA

APPROVED REV.
PH

DATE

REVISION DESCRIPTION

DES. CHK.

APPROVED

REFERENCE DRAWING No.


3400-15R-700

REFERENCE DRAWINGS
ISOMETRIC VIEW VISTA ISOMETRICA

DESIGNED BY
G. AMATO

DRAWN BY
M. STA ANA

FLOTATION REGRIND CIRCUIT STRUCTURAL CONCRETE OVERALL FOUNDATION PLAN FLOTACION CIRCUITO DE REMOLIENDA CONCRETO ESTRUCTURAL CIMENTACION GENERAL VISTA PLANTA
SCALE

ISSUED FOR SQUAD CHECK A 16APR12 EMITIDO PARA REVISION MULTIDISCIPLINARIA ISSUED FOR CLIENT REVIEW - NOT USED ----B EMITIDO PARA LA REVISION DEL CLIENTE - NO UTILIZADO

CHECK DESIGN
M. LASBY

CHECK DRAWING
CY. CAMPHAUG

1:100

LEAD ENGINEER/SPECIALIST
P. HAAGEN

APPROVAL DATE
26APR2012

-----

ISSUED FOR APPROVAL - NOT USED EMITIDO PARA APPROBACION - NO UTILIZADO


GA ML GA ML PH AK PH AK

ISSUED FOR DETAILED ENGINEERING 0 26APR12 EMITIDO PARA INGENIERIA DE DETALLE

0T 04JUL12 ISSUED FOR DETAILED ENGINEERING WITH TRANSLATION


EMITIDO PARA INGENIERIA DE DETALLE CON TRADUCCION

CLIENT
N/A

APPROVAL DATE
N/A
YES NO

1:250

DRAWING NUMBER

240K-C2-3400-15R-701

REV.

0T

SAFETY SHARE : SAFETY, IT'S FOR LIFE

COMPARTAMOS LA SEGURIDAD : LA SEGURIDAD ES DE POR VIDA


SmartSketc

MANUAL CHANGES MADE -

NOTE: THIS DRAWING WAS GENERATED FROM SMARTPLANT 3D

1/8"=1'-0"

NOTICE: THIS DRAWING HAS NOT BEEN PUBLISHED AND IS THE SOLE PROPERTY OF FLUOR AND IS LENT TO THE BORROWER FOR THEIR CONFIDENTIAL USE ONLY, AND IN CONSIDERATION OF THE LOAN OF THIS DRAWING, THE BORROWER PROMISES AND AGREES TO RETURN IT UPON REQUEST AND AGREES THAT IT WILL NOT BE REPRODUCED, COPIED LENT OR OTHERWISE DISPOSED OF DIRECTLY OR INDIRECTLY, NOR USED FOR ANY OTHER PURPOSE OTHER THAN WHICH IT IS FURNISHED.

AREA MANAGER
A. KING

APPROVAL DATE
26APR2012

ENGINEERING MANAGER
A. KING
R

APPROVAL DATE
26APR2012

1/4"=1'-0"

OVERALL FOUNDATION PLAN CIMENTACION GENERAL PLANTA

10m

3/8"=1'-0"

1/2"=1'-0"

You might also like