This drawing shows schematically the drainage channels and minimum structural requirements.

Details of the structural, geotechnical and foundation systems are to be designed by Qualified Persons.
TOP OF DRAIN TO FLUSH WITH FOOTPATH / GROUND LEVEL
SEE TABLE

25 DIA. ALUMINIUM
RUNGS AT 300 INTERVAL

CAST IN SITU WALL OF DRAIN

HARDCORE THROUGHOUT LENGTH OF WALL

50

25

600

SEE DETAILS OF

65

GEOTEXTILE COMPLYING
1000 (N.T.S.)

WITH TABLE SHOWN IN DRAWING NO . 3


1200
50

150

65

20

REBATED JOINT

1200

1200

1200

AT 2m C/C STAGGERED

25

65 DIA. PVC PIPE WEEPHOLE

1st PIECE
25

INTERMEDIATE PIECES

LAST PIECE

GRADE 25 CONC.

SECTION B-B
600

BENCHING

TYPE C3
1: 40

CHANNEL

WIDTH OF DRAIN

600

750

900

1050

1200

150x150 SPLAY
A

TABLE
SEE DETAILS OF
REBATED JOINT

THIS PIECE TO

300 COMPACTED HARDCORE 50 LEAN CONC.


150 HARDCORE

FALSE BOTTOM

WIDTH

150

BE PRECAST

300

(PILING AND FOUNDATION DETAILS TO BE DESIGNED BY QP)

SECTION A-A
A

150

75

1200

1200

1200

1200

300

23
25 DIA. ROD

PLAN VIEW
100 50

NOTES
GAP TO BE FILLED

RIBBED
90

UP WITH CEMENT MORTAR (1: 3)

1. 2.

CLEAR COVER TO REINFORCEMENT : 40mm. GRADE 30 CONCRETE IS TO BE USED. LENGTH OF PRECAST PIECE TO BE 1200mm ON STRAIGHT AND 500mm ON CURVES.

65

RIBBED RUNG

230

75

RUNG

3.

65

20

30

4. 5.

WIDTH / DEPTH RATIO OF DRAIN SHOULD NOT BE MORE THAN 1 : 2. NON-SKID ALUMINIUM RUNGS ARE TO BE PROVIDED FOR ROADSIDE DRAINS WITH DEPTH EQUAL TO OR EXCEEDING 0.9m.

25

6.

THE TOP SLAB OF THE ROADSIDE DRAIN SHALL BE CONSTRUCTED SUCH THAT PONDING AT THE TOP SLAB WILL NOT OCCUR.

ISOMETRIC VIEW (CLOSED-UP VIEW OF RUNG) PLAN VIEW

DETAILS OF REBATED JOINT


7

ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE STATED

DETAILS OF NON-SKID ALUMINIUM RUNG

DRAWING NO.

STANDARD ROADSIDE DRAINS