Inspection (Initial) of Damaged Marine Floating Hose Tail 1 Outer Hose String
Notification of damage Dec. Sat,17 2011 Hose type Tail 544 Inspection breakdown Anomaly type Cut Date of inspection Dec.18 Sun, 2011 Manufacture Dunlop ID: 42806 Inspection Type Visual Purchase Date March 2006 inspection /TA OMI/7 D. Sary Date in use November 2010

Anomaly Yes

Comments Maximum depth 74 millimeters going through the outer cover into the close cell flotation, length 260 millimeters.
( not able to determine clock position at present time do to hose attached to Tanker manifold)

Tear

Yes

Continuing from Cut - Maximum depth 74 millimeters going through the outer cover into the close cell flotation, width 170 millimeters, length 390 millimeters.
( not able to determine clock position at present time do to hose attached to Tanker manifold)

Gouge Abrasion longitudinal Ridge Bulge Cracking Rubber oil softening Contents weeping permanent Kinking permanent distortion Location of Damage

No indication No indication No indication No indication No indication No indication No indication No indication No indication

N/A N/A N/A N/A N/A N/A N/A N/A N/A

Page 1 of 3

WO: 24657164 /FC

Inspection (Initial) of Damaged Marine Floating Hose Tail 1 Outer Hose String

Page 2 of 3

WO: 24657164 /FC

Inspection (Initial) of Damaged Marine Floating Hose Tail 1 Outer Hose String
Comments recommendations Under present conditions, the hose need not be removed from service. Preliminary inspection indicates damage only in flotation and not extending into cover of secondary carcass. However requested to be verified once again. Tanker loading can be carried out using both hose strings. Due to type of hose, location in string, extent of damage (depth and length) and time in service, repair is recommended. Repairs to flotation can be accomplished at site offshore. Complete Marine hose repair kit is required to be placed on an urgent basis.