ADMIRAL Range/Stove/Oven Fault Codes

Fault Codes - Table of Contents

Failure Condition Code F1 F1 F2 Defective touch pad or membrane Watchdog on board Oven too hot

Check/Repair Replace touch pad or clock assembly (also called the ERC) (usually the touch pad) Replace touch pad or clock assembly (also called the ERC) Replace relay board (if present) or oven temperature sensor Replace oven temperature sensor Replace clock assembly (also called the ERC) Check for proper voltage Replace touch pad or clock assembly (also called the ERC) or un-stick button Replace clock assembly (also called the ERC) Check door lock circuit or replace clock assembly (also called the ERC) Replace touch pad or clock assembly (also called the ERC)

F3 or F4 Open or shorted oven temperature sensor F5 F6 F7 F8 F9 F0 Hardware and watchdog circuits disagree Missing AC signal Function key shorted or stuck button Analog/Digital trouble Door latch trouble Function key stuck

AMANA Range/Stove/Oven Fault Codes Failure Code - glass link Electronic Range Control (ERC) Door flashing #0, 1, 2, 3 Lock flashing F0 F1 F2 F3 F4 F7 Condition Check/Repair

Latch switch broken Latch switch broken Loss of safety signal Watchdog circuit Oven too hot Open or shorted oven temperature sensor Shorted touch panel

Replace Replace Replace adapter board Replace Electronic Range Control (ERC) Replace oven temperature sensor Replace oven temperature sensor Replace glass panel