Pump Identification Equations

Pump Description Eq. 1) Differential Elevation Head (H


h
)
Pump Location Eq. 2) Differential Pressure Head (H
p
)
Data Collected
Flow Data Eq. 3) Flow Velocity (V
(s, d)
)
Volumetric Flow Rate (Q) gpm (N. 1)
Suction System Data
Suction Pipe Diameter (d
s
) feet (N. 2) Eq. 4) Differential Velocity Head (H
V
)
Suction Gauge Pressure (p
s
) psi (N. 3)
Suction Gauge Elevation (h
s
) feet (N. 2)
Suction Line Loss Coefficient (K
s
) (N. 4) Eq. 5) Friction Head (f
(s, d)
)
Discharge System Data
Discharge Pipe Diameter (d
d
) feet (N. 2)
Discharge Gauge Pressure (p
d
) psi (N. 3) Eq. 6) Total Pump Head (H)
Discharge Gauge Elevation (h
d
) feet (N. 2)
Discharge Line Loss Coefficient (K
d
) (N. 4) Eq. 7) Power Output of Pump (W
o
)
I nput Power Data
Input Power to Pump Drive Shaft (W
i
) bhp (Rf. 1)
Eq. 8) Pump Mechanical Efficiency (
p
)
Assumptions
Fluid Properties
Specific Gravity (SG) 1.00
Vapor Pressure of Fluid (V
p
)
0.57 ft. abs.
Notes
Environmental Data
Barometric Pressure (p
b
)
33.95 ft. abs.
Acceleration of Gravity (g) 32.17 ft./sec.
2
Pump Head Analysis
Differential Elevation Head (H
h
)
- feet (Eq. 1)
Differential Pressure Head (H
p
)
0.0 feet (Eq. 2)
Suction Flow Velocity (V
s
)
- ft./sec. (Eq. 3)
Discharge Flow Velocity (V
d
)
- ft./sec. (Eq. 3)
Differential Velocity Head (H
V
)
- feet (Eq. 4)
Suction Friction Head (f
s
)
- feet (Eq. 5)
Discharge Fricition Head (f
d
)
- feet (Eq. 5)
Total Pump Head (H) - feet (Eq. 6)
References
Pump Performance
Power Output of Pump (W
o
)
- whp (Eq. 7)
Mechanical Efficiency of Pump (
p
)
- (Eq. 8)
N. 2) A tape measure was used to determine
the size and length of various pump system
components.
N. 3) Pressures were collected from
previously installed pressure gauges during
the site assessment.
N. 4) Line loss coefficients are estimated
based on pipe length, diameter, and material
as well as fitting type and quantity.
Rf. 1) Input power to pump drive shaft is
calculated using the Motor Analysis Tool
(MAT) on the previous page.
Pump Efficiency Analysis Tool (PEAT)
N. 1) A digital flow meter was used to
collect volumetric flow measurements.
d s
h h
2
2.31
1
d s
p p ft H O
SG psi
| |

|
\ .
( )
3
2
( , )
0.1337 1min
1 60sec
2
s d
Q ft
gal
d t

2 2
2
d s
V V
g

2
( , )
( , )
2
s d
s d
V
K
g
| |
|
|

\ .
h P V s d
H H H f f A + A + A + +
3, 960
Q H SG
o
i
W
W