Volume in Gallons
Diameter
(inches) ft
(24) 2.0
(26) 2.17
(28) 2.33
(30) 2.5
(32) 2.67
(34) 2.83
(36) 3.0
(38) 3.17
(40) 3.33
(42) 3.5
(48) 4.0
(54) 4.5
(60) 5.0
1
24
28
32
37
42
47
53
59
65
72
94
119
147
2
47
55
64
73
84
94
106
118
130
144
188
238
294
71
83
96
110
126
141
159
177
195
216
282
357
441
94
111
128
147
168
188
212
236
261
288
376
476
588
8
188
221
255
294
335
376
423
472
521
576
752
952
1175
9
212
249
287
330
377
423
476
531
586
648
846
1071
1322
10
235
277
319
367
419
471
529
590
651
720
940
1190
1469
8
25.1
29.5
34.1
39.3
44.8
50.3
56.6
63.1
69.7
77.0
100.5
127.3
157.1
9
28.3
33.3
38.4
44.1
50.4
56.6
63.6
71.0
78.3
86.6
113.1
143.2
176.7
10
31.4
37.0
42.6
49.1
56.0
63.0
70.7
78.9
87.0
96.3
125.7
159.1
196.4
1
3.2
3.7
4.3
4.9
5.6
6.3
7.0
7.9
8.7
9.6
12.6
15.9
19.7
2
6.3
7.4
8.6
9.8
11.2
12.6
14.2
15.8
17.4
19.3
25.1
31.8
39.3
3
9.5
11.1
12.8
14.7
16.8
18.9
21.3
23.7
26.1
28.9
37.7
47.7
59.0
4
12.6
14.8
17.1
19.7
22.5
25.1
28.3
31.6
34.9
38.5
50.3
63.6
78.6
V = .7854 x (D/12)2 x L
Note 1: Due to different head designs, the above tables provide only an estimated volume. Upon disagreements with
volumes taken from this table, owner should be allowed to provide more exact calculations for the specific tank.
Note 2: Volumes bolded in both Tables indicate air tank sizes 12 cubic foot volume and above which require
inspection, registration and a valid permit to operate per Boiler Code sections Comm 41.17 and 41.24.