Effective from Feb, 2010

Master list No. TIM 0015 Revision 3

RESEARCH DESIGNS AND STANDARDS ORGANIZATION TRACTION INSTALLATION DIRECTORATE


1.0 TITLE: MASTER LIST OF SCHEDULE OF TECHNICAL REQUIREMENTS OF OHE & PSI MATERIALS FOR TRACTION INSTALLATION.

PREPARED BY APPROVED BY

SE/DOC DIR.TI - P&S

Page 2 Of 10

Effective from Feb, 2010

Master list No. TIM 0015 Revision 3

2. OVER HEAD EQUIPMENT


Sl. No. SPECIFICATION NO. DESCRIPTION STR No. COST OF STR

ETI/OHE/3(2/94)

2 3 4

RE/30/OHE/5 (11/60) ETI/OHE/11(5/89) ETI/OHE/13(4/84)

Technical specification for Annealed stranded copper conductors for jumper wire for Electric Traction. Specification for Copper bus bar. Specification for Steel tubes. Specification for Hot dip zinc galvanization of steel masts (Rolled & Fabricated), tubes and fittings used on 25kV ac OHE. Specification for Stainless steel wire ropes. TI/STR/009 Rev-1 Specification for solid core porcelain TI/STR/010 insulators for 25kV a.c. 50Hz single phase Rev-0 overhead traction lines. Specification for 25kV a.c. single pole and double pole isolators for Railway Electrification. Specification for Steel and stainless steel bolts, nuts and washers . Aluminum alloy section and tubes for 25kV Traction Overhead Equipment. Specification for Dynamometers. Specification for Light weight Section TI/STR/024 insulator assembly. Rev-0 Specification for Enameled steel plates Provisional specification for retro-reflective structure Number plates. Specification for Galvanized steel wire rope. Specification for Hard drawn copper catenary. Technical specification for hard drawn grooved contact wire for electric traction (jointed/welded contact wire). Technical specification for Winch type regulating equipment for 25kV a.c. traction. Specification for Three pulley type TI/STR/027 regulating equipment (3:1 Ratio) Rev-0

5 6

TI/SPC/OHE/WR/ 1060 (06/06) TI/SPC/OHE/INS/ 0070(04/07) ETI/OHE/16(1/94)

210/350/-

8 9 10 11 12 13 14 15 16

ETI/OHE/18(4/84) ETI/OHE/21(9/74) RE/OHE/22(9/61) TI/SPC/LWTSI/ 0060 (08/06) ETI/OHE/33(8/85) ETI/OHE/33A (12/97) ETI/OHE/36 (12/73) ETI/OHE/37 (12/73) ETI/OHE/42(6/97)

280/-

17 18

ETI/OHE/48(7/84) TI/SPC/OHE/ ATD/0060(08/06)

210/-

Document1

Page 3 Of 10

Effective from Feb, 2010

Master list No. TIM 0015 Revision 3

Sl. No.

SPECIFICATION NO.

DESCRIPTION

STR No.

COST OF STR

19 20

ETI/OHE/49(9/95) ETI/OHE/50(6/97)

Technical specification for Fittings for 25 kV ac OHE Technical Specification for cadmium copper conductors for overhead Railway traction Technical Specification for 37/2.25 mm. Hard Drawn Stranded copper conductor. Specification for Discharge/earthing pole assembly for 25kV ac traction. Specification for Interlocks for ac traction switchgears Principles for OHE layout plans and sectioning diagrams for 25kV ac traction. Specification for 19/2.79mm all aluminum alloy, stranded catenary wire. Specification for Bimetallic (aluminium copper) strip. Technical specification for 4 wheeler overhead equipment inspection car 1676 mm. Gauge. Specification for hand operated lifting and swiveling platform. Technical specification for 8 wheeler OHE inspection car 1676mm gauge Specification for Short Neutral Section Assembly (Phase Break) Specification for solid core cylindrical post insulators for systems with nominal voltages of 220kv,132kv,110kv & 66kv Specification for continuous cast copper wire rods. Code of bonding and earthing for 25kv a.c. 50Hz single phase traction system.
Specification for 4 axle car for winding and/or unwinding of contact wire and catenary wire. Technical Specification for hard drawn grooved contact wire for electric traction drawn out of continuous cast copper (ccc) wire rods.

TI/STR/023 Rev-0 TI/STR/020 Rev-0

210/350/-

21

22 23 24 25 26 27

TI/SPC/OHE/ HDCSCF/0030 (06/03) ETI/OHE/51(9/87) ETI/OHE/52 (10/84) ETI/OHE/53(6/88) ETI/OHE/54(2/85) ETI/OHE/55(4/90) TI/SPC/OHE/ 4WDHTW/0070 (06/07) ETI/OHE/58/1 (1/95) TISPC//OHE/ 8WDHTW0070 (06/07) TISPC/OHE/SNS/ 0000(01/00) ETI/OHE /64 (10/88) ETI/OHE/65(8/87) ETI/OHE/71 (11/90) ETI/OHE/72 (11/91) ETI/OHE/76(6/97) TI/SPC/OHE/ TOOLPL/0990 (02/03)

28 29

30 31

TI/STR/024 Rev-0

280/-

32 33 34 35 36

TI/STR/025 Rev-0

280/-

TI/STR/017 Rev-0

280/210/-

Gearless hand operated pulling and lifting TI/STR/007 machines(TIRFOR) Rev-1

Document1

Page 4 Of 10

Effective from Feb, 2010

Master list No. TIM 0015 Revision 3

Sl. No.

SPECIFICATION NO.

DESCRIPTION

STR No.

COST OF STR

37 38

TI/SPC/OHE/TOOLPL /1990(11/99) TI/SPC/OHE/INSCAT / 0000 (04/00)

Ratchet lever Hoist (Pull-lifts)

39

TI/SPC/OHE/TIPS/ 0010(03/01) TI/SPC/OHE/TIPS/ 1030(06/05) Rev-1 TI/SPC/OHE/TIPS/ 2030(08/03) TI/SPC/OHE/ GALSTB /0040(09/04) TI/SPC/OHE/CWRIG/ 0090(09/99) TI/SPC/OHE/ INSCOM/1070(01/07) TI/SPC/OHE/FRPNP/ 0060(06/06) TI/SPC/OHE/ CW/WEAR/0030 (02/08) TI/SPC/OHE/GATD/ 0080(9/08) TI/SPC/OHE/ 8WDEIC/00900(02/09) TI/SPC/OHE/INSTES T/0090(02/09)

40

41 42

43 44

45 46

47 48

49

TI/STR/007 Rev-1 Insulated Cadmium Copper Catenary TI/STR/018 19/2.1mm. Diameter for provision under Rev-0 overline structures in the 25 kV ac. Electric traction. Technical specification for infrared imaging system for handheld application Technical specification for infrared imaging system for stationary Installation Specification for Loco mounted current collection checking and analysis system Technical specification for galvanized steel stranded wire for traction bonds for 25 kV. ac. Electric traction system Technical specification of ` Test ring, for wear of contact wire. Technical specification for Silicone TI/STR/006 composite insulators for 25kV ac 50Hz Rev-0 single phase overhead traction lines. Specification for Retro-Reflective structure number plate on FRP b.ase Technical specification for on Board Equipment for line scanning for thickness of contact wire used in 25kV ac traction. Technical specification for Gas Auto tensioning device. Technical specification for 8-Wheeler Diesel Electric inspection & maintenance Car B.G. (167mm)gauge. Specification for Testing load testing Machine 25kV Porcelain & Composite insulator before installation.
Schedule of Technical Requirements for Manufacture of Galvanised Steel Stranded Wire (GSSW)

210/280/-

280/-

50

TI/SPC/OHE/GSSW/0 090(10/2009)

TI/STR/0029

280/-

Document1

Page 5 Of 10

Effective from Feb, 2010

Master list No. TIM 0015 Revision 3

3.POWER SUPPLY INSTALLATION


Sl. No. SPECIFICATION NO. DESCRIPTION STR No COST OF STR

1 2 3 4 5 6 7 8

ETI/PSI/1(6/81) ETI/PSI/14(01/86) ETI/PSI/15(08/2003) ETI/PSI/15A (7/82) ETI/PSI/24(6/81) ETI/PSI/31(5/76) ETI/PSI/36(5/75) TI/SPC/PSI/CLS/ 0020(12/02) ETI/PSI/44(12/73)

Battery charger for 110 volt battery, 40 Ah. 25 kV. Dropout fuse switch 25 kV/240V Auxiliary transformer, 5 kVA, 10kVA., 25kVA.& 50kVA. 25 kV / 240V Auxiliary transformers, 100kVA. Battery charger for 110 V. battery 200 Ah. Standards for drawings for power supply installation. Current transformer, 132 kV (type II) Control & distribution panel for colour light signaling supply in 25 kV ac. traction systems. Standards for electrical distribution system in stations & yards where 25 kV ac traction is to be introduced.

TI/STR/016 Rev-1 TI/STR/016 Rev-1

280/280/-

TI/STR/008 Rev-1

280/-

10

11

TI/SPC/PSI/PROTCT Control and relay panel for 25kV ac TSS /6070(9/08) including specification for numerical type protection relays for traction transformer, 25kV shunt capacitor bank and transmission line for 25kV AC TSS on Indian Railways. ETI/PSI/67(11/96) Shunt capacitor equipment for Railway traction sub-stations. Series reactor for 25kV a.c. traction system ETI/PSI/71 Rev-1 (01/87) ETI/PSI/72 (9/85) ETI/PSI/75(10/97)

TI/STR/001 Rev-1 TI/STR/002 Rev-2 TI/STR/004 Rev-0 TI/STR/005 Rev-0

280/280/-

280/280/-

12

13 14

Metal oxide gapless type lightning arrester for use on 25 kV. side of Railway traction substations and switching stations. Electric power connectors for AC. Traction power system. 25 kV, 50 Hz single phase series TI/STR/005 Compensation Equipment. Rev-0

Document1

Page 6 Of 10 15

Effective from Feb, 2010

Master list No. TIM 0015 Revision 3 280/-

ETI/PSI/90(6/95)

25 kV ac 50 Hz single phase oil filled TI/STR/019 current transformers with ratio of (i) 1000- Rev-0 500/5A, (for general purposes, (ii) 1500750/5 (for heavy duty).

Sl. No.

SPECIFICATION NO.

DESCRIPTION

STR No

COST OF STR

16 17 18

ETI/PSI/98(8/92)

19

20 21

22

26

27

23 24

25

100 KVA. And 150 KVA. 25 kV single phase 50 Hz, oil filled booster transformer. ETI/PSI/99(4/89) Trivector meter and Maximum Demand Indicator for Railway a.c. Traction. TI/SPC/PSI/ISOLTR/ Specification for 25kV. AC Single pole and 1060(08/06) Double pole Motorized Isolators for Railway Electric traction. TI/SPC/PSI/DRPC/ Dynamic reactive power compensation 0050(08/05) equipment for Railway traction sub-stations (for development of prototype only). ETI/PSI/105(7/93) Gas Chromatograph for use in analysis of dissolved gases of transformer oil. ETI/PSI/106 (10/87) Capacitance bridge and dissipation factor bridge for the measurement of solid insulation of insulating oil. ETI/PSI/117(7/88) Current transformer (i) 220 kV, 200-100/5 (ii) 132 kV, 400-200/5 (iii) 110 kV, 400-200/5 (iv) 66 kV, 800-400/5 ETI/PSI/118 (10/93) Power transformer 21.6 MVA, single phase 50 Hz, 220/132/110/66/27kV for traction substation. ETI/PSI/120(2/91) Code of practice for earthing of power supply installation for 25 kV. Ac. 50 Hz single phase traction system. ETI/PSI/122(3/89) Specification for 245/145/123/72.5 kV double pole and triple pole isolators. ETI/PSI/123(9/93) 21.6 MVA, 220/132/110 / 66 kV/2x27 kV, single phase, 50 Hz Traction power transformer for AT feeding system ETI/PSI/124(7/95) 54 MVA, 220/2x27 kV Scott-connected power transformer for 2x27 kV AT feeding system.

TI/STR/026 Rev-0

350/-

TI/STR/022 Rev-0

280/-

TI/STR/014 Rev-1

410/-

TI/STR/014 Rev-1 TI/STR/014 Rev-1

410/-

410/-

Document1

Page 7 Of 10 26

Effective from Feb, 2010

Master list No. TIM 0015 Revision 3 410/-

ETI/PSI/125(7/97)

27 28

ETI/PSI/126(8/89) ETI/PSI/127(8/89)

8 or 5 MVA, 2x27 kV 50 Hz, auto TI/STR/014 transformer for 2x27 kV AT feeding Rev-1 system. 25kV shunt capacitor equipment for 2x25kV `AT feeding system. Series capacitor equipment for 2x25 kV`AT feeding system.
DESCRIPTION STR No

Sl. No.

SPECIFICATION NO.

COST OF STR

29 30 31 32

33 34

35

36 37 38

39

40

41

Resonance suppressing C-R device for 2x25KV `at feeding system. ETI/PSI/129(8/89) Distance relay for 2x25 kV `AT feeding system. ETI/PSI/130(8/89) Delta-I type fault selective relay for 2x25 kV `AT feeding system. ETI/PSI/132(8/89) 25 kV double pole outdoor, vacuum interrupters for Railway switching stations for 2x25 kV AT feeding system. ETI/PSI/133(8/89) 25 kV ac double pole isolators for 2x25 kV AT feeding system. ETI/PSI/135(8/89) `AT Boost up current ratio type fault locator for OHE for 2x25kV `AT feeding system. ETI/PSI/137(8/89) Metal oxide gapless type lightning arresters for use of 220/132/110/66 kV side of railway ac traction substation. TI/SPC/PSI/LCMLA/ Technical specification for leakage current 0030(04/03) monitor for lightning arrester ETI/PSI/138(8/89) Control and relay board for 2x25 kV `AT feeding system. ETI/PSI/139 (12/89) 25 kV ac double pole outdoor SF6 interrupters for 2x25 kV AT feeding system. TI/SPC/PSI/ Technical specification for Microprocessor PROTCT/5070 based Numerical Integrated feeder (05/07) Protection Module Comprising DPR, INST. OCR., PTFF & Auto Reclosure Relay for 25kV. AC single phase 50 Hz traction SubStation. ETI/PSI/144(12/91) Supervisory control and data acquisition (SCADA) system for 2x25kV. ``AT Traction power supply. ETI/PSI/145(3/92) Specification for 11 kV current transformer with ratio 500/5 for 2x25 kV AT feeding

ETI/PSI/128(8/89)

TI/STR/015 Rev-0

280/-

TI/STR/015 Rev-0 TI/STR/001 Rev.-1

280/-

280/-

Document1

Page 8 Of 10

Effective from Feb, 2010 system.

Master list No. TIM 0015 Revision 3

42

ETI/PSI/147(3/92)

Specification for 25 kV current transformer with CT ratio 100-50/5 for shunt capacitor banks in 2x25 kV AT feeding system.

Sl. No.

SPECIFICATION NO.

DESCRIPTION

STR No

COST OF STR

43 44 45

ETI/PSI/148(4/92) ETI/PSI/150(4/94)

46 47

48

49

Specification for SF6 gas leakage detector. 25 kV ac 50 Hz outdoor pole mounted SF6 interrupter. ETI/PSI/151(1/96) Microprocessor based compact control, protection and metering system for 25kV ac traction sub-stations on Indian Railways. ETI/PSI/159 (10/94) 25 kV ac 50 Hz single pole outdoor pole mounted vacuum interrupter. ETI/PSI/163 (4/97) 21.6 MVA, 100/27 kV OR 22/27 kV single phase, 50 Hz, ONAN traction power transformer. ETI/PSI/167 (9/97) 25 kV, 50 Hz Single Pole outdoor Interrupter for Railway Traction switching station. TI/SPC/PSI/VACINT Magnetic actuator type 25 kV. Ac. 50 Hz, /0040(05/05) single pole , outdoor vacuum interrupter for railway traction switching station Prototype Specification for Delta-I type High Resistive fault selective relay for 25 kV ac traction systems. Prototype Specification for Panto Flashover Protection relay for 25 kV a.c. traction system TI/SPC/PSI/PROTCT Control and relay panel for protection /4050(11/05) system of Mumbai Area for 50 Hz AC Traction power supply system including parallel operation on 25kV. Side. TI/SPC/RCC/ SCADA/0990(05/07) Vol. 1 & 2 TI/SPC/PSI/PTS/ 0990(09/99). TI/SPC/ PSI/ CB/ TI/SPC/PSI/ PROTCT/1982 (12/03) TI/SPC/PSI/PROTCT /2983(09/01)

TI/STR/015 Rev-0

280/-

TI/STR/014 Rev-1 TI/STR/015 Rev-0

410/-

280/-

50

TI/STR/001 Rev-1 TI/STR/001 Rev-1

280/-

51

280/-

52

53

54 55

TI/STR//00 1 Rev-1 TI/STR/002 Rev-1 Prototype technical specification for TI/STR/028 SCADA, 25 kV single phase 50 Hz a.c. Rev-0 traction power supply (Not for general use as validation is yet to be done) For 220 kV. Or 132 kV. Or 110 kV. Or 66 kV. Or 25 kV. Potential transformer Outdoor circuit breaker for 25 kV. Ac. TI/STR/015

280/280/-

410/-

280/-

Document1

Page 9 Of 10

Effective from Feb, 2010

Master list No. TIM 0015 Revision 3

56

0000(05/00) TI/SPC/PSI/30TRN/ 0030(06/03) TI/SPC/PSI/30TRN/ 1050(12/05)

Traction sub station Rev-0 30MVA, 22/27 kV Single Phase Traction TI/STR/014 Power Transformer. Rev-1 30MVA,110/27kV Single phase traction TI/STR/014 Power transformer with on load top Rev-1 changer(for use in Mumbai Sub-Urban Area)
DESCRIPTION STR No

410/-

57

410/-

Sl. No.

SPECIFICATION NO.

COST OF STR

58

TI/SPC/PSI/30TRN/ 2070(10/07)

59

TI/SPC/PSI/OFC/ 0050(10/05) TI/SPC/PSI/PQLAR/ 0080(09/08) TI/SPC/RCC/ SCADA/1080(9/08)

60 61

62

TI/SPC/PSI/ TESTKIT/1080 (12/08)

63

TI/SPC/PSI/CABLE/ 0090(02/09)

30MVA,220/27kV,110/27kV, & 66/27kV Single phase traction Power transformer ONAN/ONAF with on load top changer (for use in TSSs other than Mumbai area). 25 Core Armoured Optic Fibre Cable for use in Indian Railways traction installation systems Technical specification for power quality analyzer and Recorder with Remote display. Technical specification for Supervisory control and data acquisition system for 25kV single phase 50 Hz ac traction power supply for Mumbai area. Relay testing kit for testing of Static/Electro magnetic /Micro-processor based numerical protection relays used for 25kVac, 50Hz, single phase traction system of Indian Railways. Manufacture and supply of 132kV XLPE underground cable and accessories.

TI/STR/014 Rev-1

410/-

TI/STR/028 Rev-0

410/-

4.0 CIVIL SPECIFICATION

S. No.

SPECIFICATION

N0.

DESCRIPTION

TI/STR/No.

COST OF STR

ETI/C/2/(8/94)

2 3

ETI/C/3(5/83) ETI/C/4(8/90)

Technical specification for spun pre- TI/STR/021 stressed cement concrete (PSC) OHE Rev-0 traction mast. Indian Railway standard specification for spraying zinc coating on the OHE mast. Draft Indian Railway Standard specification for cold roll formed mast for Railway electrification.

350/-

Document1

Page 10 Of 10 4 5

Effective from Feb, 2010

Master list No. TIM 0015 Revision 3

ETI/C/5(5/88) TI/SPC/CIV/POR/ 0080(08/2008)

Specification for Flo-Coat Tube Corrosion Resistant Paint System for outdoor structures of Traction Distribution and Traction Rolling Stock.

5.0 DISTRIBUTION S. No 1 2 3 4 5 6 Copy holder Sr. ED/TI EDTI DTI-PSI DTI-P&S DTI-OHE SE/DOC/TI-I 01 02 03 04 05 06 Master copy for record Copy Number

SE/DOC/TI -