Example: Terminal Stacking
Example: Terminal Stacking
To prevent corrosion from dissimilar metals, put a cadmium washer between aluminum and copper terminals.
Grounding Definition
4Grounding is the process of
electrically connecting conductive objects to either a conductive structure or some other conductive return path for the purpose of safely completing either a normal or fault circuit.
4
Grounding
4Types of grounding
AC returns DC returns Others
various sources
Noise will be coupled from one source to another and can be a major problem for digital systems
5
Grounding, cont.
4Design of ground path should be
constant impedance
4Ground equipment items externally
Grounding, cont.
4Heavy current grounds
Attach to individual grounding brackets attached to aircraft structure with a proper metal-to-metal bond Accommodate normal and fault currents of system without creating excessive voltage drop or damage to structure Give special attention to composite aircraft
7
Bonding
4Equipment bonding
Low impedance paths to aircraft structure required for electronic equipment to provide radio frequency return circuits Facilitates reduction in EMI for most electrical equipment
4
Bonding, cont.
4 Metallic surface bonding
Electrically connecting conductive exterior airframe components through mechanical joints, conductive hinges, or bond straps
4
4Wire marking
4 Connectors and conduits 4 Wire insulation properties
NBAA Conference 2003
10
Wire Marking
4Necessary for:
Safety of operation Safety to maintenance personnel Ease of maintenance/troubleshooting
use wire material part number and five digit/letter code identifying manufacturer
NBAA Conference 2003
11
type, and color at 15-inch maximum intervals along the wire [directly on wire or indirect (sleeve/tag)]
13
14
Connectors
4 Many types of connectors, however crimped contacts generally used
4 Selected to provide max. degree of safety and reliability given electrical and environmental requirements
Circular Connectors
16
incorrect
17
correct
18
Rectangular Connectors
19
20
View A Acceptable
grommet
NBAA Conference 2003
View B Unacceptable
21
22
Conduits
4Purpose
4Standards
Absence of abrasion at end fittings Proper clamping Adequate drain holes free of obstructions Minimized damage from moving objects Proper bend radii
23
.2"
Select an answer: a. 1 inch b. 5 inches c. 7 inches d. 8 inches e. 7.4 inches
NBAA Conference 2003
25
Flame resistant Mechanical strength Smoke emission Fluid resistance Heat distortion
resistance
Corrosion
Cut-through Dielectric
26
Mil Spec
22759/12 22759/16
22759/80-92
27
Plus
Conclusion on Insulation
4Aircraft designer can choose among
29
provided in AC 43.13-1b
4Should apply to new airplanes,
as well as modifications
4Not intended to take the place of
30
31
Wire Separation
4Regulatory requirements
4Manufacturers standards
EMI concerns
32
Clean-as-you-go Philosophy
4Keep wiring clean throughout
life of aircraft
Protect
wiring during routine maintenance wiring periodically (vacuum, light brushing, etc.) during heavy maintenance when hidden areas exposed
33
Clean
Focus Areas
4Clamping 4Connectors
points
Worn seals Loose connectors Lack of strain relief Drip loops Tight wire bends
34
4Grounding
Lugs/splices
points
Tightness Cleanliness Corrosion
4Backshells
Improper build-up Lack of strain relief
4Damaged sleeving
and conduits
NBAA Conference 2003
35
4Engine/APUs/pylon/nacelle
Environmental/vibration/chemical
36
High density areas High maintenance activity Prone to broken/damaged wires Chemical contamination/corrosion Feeder terminations Signs of heat distress
4 Batteries
4 Power feeders
37
38
Questions ??
39
Thank You
40