Corrosion Under Insulation

A practical prevention guide as per API 570

All rights reserved to thepetrostreet.com

Moisture Sources
W Water Leaks L k

Mist Spray from


Cooling Towers

Condensation

CUI

Rains

Deluge systems

Leaking Process fluids

All rights reserved to thepetrostreet.com

Common Forms

Localized Corrosion of Carbon Steel

Chloride Stress Corrosion of Austenitic Stainless Steels

All rights reserved to thepetrostreet.com

Susceptible Piping Systems

A Areas exposed d to

Mist of Cooling Towers

St Steam Vents V t

D l Systems Deluge S t

P Process S Spills ill

A id V Acid Vapors

Carbon Steel Systems insulated for Human p protection operating p g between -4 deg C 120 deg C Systems S t where h operating ti temperatures t t cause frequent condensation and re-evaporation of atmospheric moisture

Carbon Steel Systems operating above 240 deg d C with ith iintermittent t itt t service i

Austenitic A t iti SS systems t with ith operating ti Temperature between 65 deg C to 204 deg C (Chloride Stress Corrosion)

All rights reserved to thepetrostreet.com

Susceptible Piping Systems

Deadlegs and attachments protruding from insulation

Vibration systems with damaged Insulation and jacketing

Steam tracing systems with tracing leaks

S Systems with hd deteriorated d coating and d wrapping

All rights reserved to thepetrostreet.com

Susceptible Common Locations

Penetrations/breaches in jacket

Damaged/missing jacketing

Hardened, separated, or missing caulking

Piping low points in systems that have insulation breach

Jacket seams on top of horizontal piping or improperly lapped/sealed jacket

Carbon or low-alloy steel components in high-alloy systems

All rights reserved to thepetrostreet.com

Susceptible Common Locations

Termination in insulation at flanges and other piping components

Termination of insulation in a vertical pipe

Bulges or staining of insulation or jacketing system (bulges may indicate corrosion products)

All rights reserved to thepetrostreet.com

Special Considerations

Insulation damage at higher elevations May cause CUI at lower elevations

Insulation removal, RT may be required

Expand inspection as necessary

Systems may be excluded:


1. 2 2. Remaining life > 10 years Ad Adequately l protected d externally ll

All rights reserved to thepetrostreet.com

Piping Service Classes

All rights reserved to thepetrostreet.com

Recommended Inspection Interval

All rights reserved to thepetrostreet.com

CUI Inspection Targets

All rights reserved to thepetrostreet.com