Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

EXPERIMENT NO: PR3

AC ENERGY METER

CALCULATIONS:
Given value for meter constant = 600 rev/kWh
1. When phase angle, =
n = 1, W = 140W and T = 40s
Measured meter constant =

110003600
14040

= 642.857 rev/kWh
% Error in meter constant =

(642.857600)
600

100%

= 7.143%
Similarly,
I(A)

Measured Meter Constant

% Error in Meter Constant

642.857

7.143

689.655

14.943

681.818

13.636

666.667

11.111

657.895

9.649

2. When phase angle, =


n = 1, W = 200W and T = 28s
Measured meter constant =

110003600
20028

= 642.857 rev/kWh
% Error in meter constant =

(642.857600)
600

100%

= 7.143%
Similarly,
I(A)

Measured Meter Constant

% Error in Meter Constant

642.857

7.143

650.407

8.401

645.161

7.527

627.178

4.53

629.371

4.895

3. When phase angle, =


n = 1, W = 40W and T = 113s
Measured meter constant =

110003600
40113

= 796.460 rev/kWh
% Error in meter constant =

(796.460600)
600

100%

= 32.743%
Similarly,
I(A)

Measured Meter Constant

% Error in Meter Constant

796.460

32.743

727.273

21.212

750

25

745.342

24.224

750

25

TABLES:
1. When phase angle, =

I(A)

% Error in Meter Constant

7.143

14.943

13.636

11.111

9.649

2. When phase angle, =

I(A)

% Error in Meter Constant

7.143

8.401

7.527

4.53

4.895

3. When phase angle, =

I(A)

% Error in Meter Constant

32.743

21.212

25

24.224

25

You might also like