Calculation Pig Runtime using Panhandle B Eqn (No liquids in line) P1 Pressure at wellhead (Absolute) (Kpa) d S.

G L Tavg Temp of gas K 313.15

ID of Pipe m

Specific gravity Length of line of gas m

0.150 6101.3

0.59

7,400

Launcher

Your input data: P1 (barg) P2 (barg) Pipe Dia (mm) Length of line S.G z (comressibility) Temp STP ST (K) SP (Kpa)

60 0 150 7400 0.59 0.9 25 288.15 101.325

Wellhead Pressure Open to atmosphere (Atm Flare) Given Given Given Approximate for 95% C1 and some other gas at 60 barg & 25C Given

Results: Qsc

1,563,941 18.10

sm3/d sm3/sec

55.23

MMscfd

Convert to actual flow P1 (kpa) V1 (m3) 101.325 18.1 Qac 0.29 C.S area of pipe 0.02 Velocity 17 Pig Run Time 445 7.4

TI (K) 288.15 am3/sec m2 m/s seconds minutes

Z1 1

P2 (Kpa) 6101.3

Reference: Campbell gas conditioning & processing VOL1 Panhandle B equation for gas transmission lines

untime using Panhandle B Eqn (No liquids in line) Zavg E K P2 Outlet pressure (Absolute) (kpa) 12,640,000 101.33

Pipeline efficiency (usually 0.88 TO Compressibility of gas 0.94). 0.92 as per Campbell 0.9 0.92

Reciever

1 and some other gas at 60 barg & 25C

Qac (am3/sec) 0.29

T2 (K) 313.15

Z2 0.9