Professional Documents
Culture Documents
Parking OB1
Parking OB1
5/13/2010 9:36:35 AM
OB1 - <offline>
Family: Version: 0.1 Block version: 2 5/13/2010 9:35:57 AMAM Time stamp Code: 2/15/1996 4:51:12 PMPM Interface: Lengths (block/logic/data): 00206 00084 00020 "Cycle Execution" Name: Author:
Name TEMP OB1_EV_CLASS OB1_SCAN_1 OB1_PRIORITY OB1_OB_NUMBR OB1_RESERVED_1 OB1_RESERVED_2 OB1_PREV_CYCLE OB1_MIN_CYCLE OB1_MAX_CYCLE OB1_DATE_TIME
Data Type
Address 0.0
Comment
Bits 0-3 = 1 (Coming event), Bits 4-7 = 1 (Event class 1) 1 (Cold restart scan 1 of OB 1), 3 (Scan 2-n of OB 1) Priority of OB Execution 1 (Organization block 1, OB1) Reserved for system Reserved for system Cycle time of previous OB1 scan (milliseconds) Minimum cycle time of OB1 (milliseconds) Maximum cycle time of OB1 (milliseconds) Date and time OB1 started
Date_And_Time 12.0
Block: OB1
Network: 1
"Start" "Flag"
"Stop"
"Flag"
Network: 2
"Flag" "Flag"
"Ulaz" "Izlaz"
"Nema_ mesta" CU CD
Page 1 of 2
SIMATIC
5/13/2010 9:36:35 AM
Network: 3
"Flag" EN "Stanje1" IN
Network: 4
"Flag"
CMP <I
"Nema_ mesta"
Network: 5
"Flag"
"Nema_ mesta"
"Slobodno"
Page 2 of 2