Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Ref:SEAOC Seismic Design Manual Vol1:

As per IS code the basement is excluded.

Second example showing the height above the raft:

IS 1893-2002 (Part 1) 7.6 Fundamental Natural Period7.6.1 The approximate fundamental natural period of vibration ( Ts ), in seconds, of a moment-resisting frame building without brick in.fd panels may be estimated by the empirical expression:

where h = Height of building, in m. This excludes the basement storeys, where basement walls are connected with the ground floor deck or fitted between the building columns. But it includes the basement storeys, when they are not so connected. EXAMPLE 3: As per IS code the following example is including the basement. The figure shows a store house building consisting a GF,Mazzanine and 8 repeated floors and two basements. Live load and floor heights are shown in elevtion. Due to EQ loads it is required to : a. Calculate the story shear at each floor level and draw its distribution on the height of the building. b. Find the BMs and SFs acting at base level.

Plan.

NOTE THE HEIGHT H AS 39 M REFERING THE ELEVATION. Compiled by Er.T.RangaRajan.