Dwelling Unit Electric Service Load Calculation V1.8


General Lighting Need Help? 3va/ft^2 of floor area, including unused space adaptable for future use. Floor Area= 0 ft^2 0 Basement Floor Area= 0 ft^2 0 Small Appliance Load 1500va for each 20 amp branch circuit required per 210.1(C)(1) in EACH kitchen, pantry, breakfast room, dining room, or similar areas. # of Small Appliance Branch Circuits = 2 X 1500va= 3,000 Laundry Load # of Laundry Branch Circuits = 1 X 1500va= 1,500 Total General Lighting & Appliance Load= 4,500 Lighting Load Feeder Demand Factors First 3000 or less at 100% 3,000 From 3001 to 120,000 at 35% 525 Remainder over 120,000 at 25% 0 Total Lighting Demand Load= 3,525 Electric Clothes Dryers Dryer #1, Greater of Nameplate KW rating or 5kw= kw Dryer #2, Greater of Nameplate KW rating or 5kw= kw Electric Ranges--Dwelling Units Electric Range Nameplate KW= kw Wall Mounted Oven Nameplate KW= kw Electric Cooktop Nameplate KW= kw Electric Cooking Demand Load= Largest of Fixed electric space heating loads or A/C load: Non-coincident Loads Fixed Electric Space Heat #1 w A/C#1 MCA@208-240V Fixed Electric Space Heat #2 w A/C#2 MCA@208-240V Fixed Electric Space Heat #3 w A/C#3 MCA@208-240V Total Non-coincident Load= Appliance load--Dwelling Units Description va(watts) Qty Description va(watts) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Total Connected Appliance Load= Appliance load--Dwelling Units Total Appliance Demand Load= Motor Loads @ 120 Volts Description Amps Qty Description Amps 0 0 0 0 0 0 0 0 0 0 0 0 Total Motor Load= 25% of Largest Motor Load Total Motor Demand Load va va

220.52(A)

va va va va va va va w w

220.52(B)

220.42

220.54

220.55

220.51 220.21

va

220.53 Qty 0 0 0 0 0 0 0 0 0 220.53 220.50 Qty 0 0 0 0 430.24

va va

va va va

TOTAL CALCULATED DEMAND LOAD in Volt-amperes = TOTAL CALCULATED DEMAND LOAD in AMPS @ 1 Phase 3 Wire, 120/ 240 Volts = Find this template at: www.naperville.il.us/loadcalculator.aspx

3,525 va 15 Amps

MINIMUM SERVICE REQUIRED

100 AMPS

SERVICE SIZE REQUESTED =

100 Amps