Client: Project Location: Project Desc:

Tank Desc: Job Number: Rev Number:

Designed By: Checked By: Date:

Rectangular Tank Design


I. Horizontal Stiffener Design (Short Side)
57

2. Member Properties
UBLT1 = 12.00 ft Mup = 86.29 ft kip IB = 291.00 in CbB = 1.00 CwB = 887.00 in SxB = 42.00 in dB = 13.80 in twB = 0.27 in cB = 1.00
3 6 4

Unbraced length of top flange Ultimate positive moment Moment of inertia of beam Bending diagram factor Torsional constant Strong axis section modulus Beam depth Beam web thickness Factor used for LTB capacity

UBLB1 = 12.00 ft Mun = 89.99 ft kip ZxB = 47.30 in ryB = 1.49 in IyB = 19.60 in rtsB = 1.77 in tfB = 0.39 in bfB = 6.73 in hoB = 13.41 in
4 3

Unbraced length of bottom flange Ultimate negative moment Plastic section modulus Weak axis radius of gyration Weak axis moment of inertia Torsional radius of gyration Beam flange thickness Beam flange width Center to center of flanges

www.mathcadcalcs.com