Submission3Guidelinesindividualmarks.

(1) PIDstakeawhiletoconstruct.Dontleaveittothelastminute. (2) Theyneedtobeneatandinagrid.IrecommendtheuseofMSVISEOwithagridded templateconstructedinitially(ifnotalready). (3) Allpipework/equipmentneedstobeshownALL. (4) Alllinesneedstobenumberedaccordingtoconventionshowinglinenumber,materialof construction,fluidcontainedanddiameter. (5) Morethan1PIDpagepersectionisfine. (6) Ensureallcontrolisindicated.Donotovercomplicatethecontrolschememakesureitcan handlestartupandshutdown. (7) DontforgetsafetyPSVs,NRV(dontoveruse),alarms,interlocksandtrips. (8) Allvessels,pumpsetc.needtobeabletobeventedand/ordrained. (9) Goldenrulenomorethan1controlvalveperline.Donotviolate. (10)Checkforconsistencybetweensections,particularlywithrespectto(9). (11)Regardingdetailsofthecontrolinyoursection.Youcantabulatethecontrolloopsthis canhowevergetveryrepetitive.Wewanttoseeyourthoughtprocessabouthowtheplant willbecontrolled(andstartedupandshutdown).