Order

FE-1203 Air

Design Check

Du hai yang Xu xing wei

Medium
Shan xi Yi xin Measurement & Control Meter Co., Ltd

Calculating book of flow meter Order Unit Name of item 1.Throtting component :

2011.01.08 Tube 893.5 Date Quan One Length (mm) Tel 029-68510536 68510537 Fax:029-68510538( Auto.)

BXY-FG-CB-80

Plug-in dual-bus tube flowmeter

2.Tapping way Take special pressure 3.Medium : Air 3 4.Scale flow: 2000Nm /h 5.Max flow: 1380Nm3/h 3 6.Com.flow: 1020Nm /h 7.Operative pressure :P=800KPa 8.Operative temperature :t=40 9.Tube:893.5(mm) 3 10. Standard DensityN=1.293kg/Nm 11.Operative density:=10.03kg/m3 12.Testing coefficient :K=1.45 13.Mathematic model with pressure and temperature automatical compensate: QN =0.846
3

P( P + Ph ) t + 273.15

QN ____ gas flow, Nm /h t _____ gas temperature, Ph____ local atmosphere, Pa P_____ Static pressure in tube, Pa P____ Pressure Difference of inter Vinturis pipe, Pa 14.Example: When P=800000Pa t=40 Ph=101000Pa 3 1QN =2000Nm /h then P=1939Pa 3 2QN =1020Nm /h then P=504Pa 15.Scale of difference pressure transducer:02000Pa(420mA)