RRC Rej and RAB Fail and reason is due to DL Power Cong. due to Cell DL load sim ulation.

After Check the site has many DL RAB Etab. Fail due to DL power Cong. As we chec ked the alarm and found during the DL power Cong. showing Cell DL Load Simulatio n Startup. Someone has startup the DL Simulation and not off that cause simulati on goes upto 99% and due to that cause many DL power Cong. As we stop the Simula tion problem is solved. RRC Connection Setup Rejection due to Radio Link Failure The RADIO LINK SETUP FAIL was sent by NodeB, so we need to investigate NodeB side.

After analyzing the NodeB mainboard log, it was found that the above problem was caused by Dynamic CE allocation. Dynamic CE is a software that schedule DSP resources periodically to drive u sers to achieve a total high and balanced throughput. There are 2 UL DSPs on BBU, DSP1 and DSP4. DSP1 controls 4 ASIC chips, and DSP4 controls 2. When users built on DSP4 cannot grab NDC resources from DSP1, and within DSP 1,users built on one chip cannot grab NDC resources from another. This is why RL failures happen to users that setup on DSP4. Another module, RM (Resource Manager), guarantees each user with minimun res ources and Dynamic CE schedule each accessed user to make most of NodeB resource s. When a new user tries to access,Dynamic CE module may need to release some r esources from other users. When a large amount of users try to access and exhaust NDC resources, and ac tion usch as Add or Reconfigure that need to grab NDC resources between ASIC chi ps may fail due to Dynamic CE way of fucntion.