Professional Documents
Culture Documents
Waff Cap Cty
Waff Cap Cty
Waff Cap Cty
h=550 mm
concrete K400 fc=35MPa
bf=900 mm
reinforcement fy=420MPa
tf=75 mm
bw=220 mm
clear cover 30 mm
As
1 main RC dia
2 lateral RC dia
as1= 30 + 0.5*1
as2=30 + 1 + 0.52
d1=550-as1
d2=550-as2
Design formulas :
Ts=As*fy
Ac=Ts/0.85fc
a=Ac/bf (should be less than tf N.A. in flange => rectangular section )
z=d-a/2
Mn=0.90*Ts*z (tm) flexural strength
Ms = Mn/0.90/1.50 (tm/m) slab flexural capacity at service stage
MAIN REINFORCEMENT CAPACITY
main RC
2
As(cm )
as(cm)
Ms(tm/m)
232
16.08
4.60
22.10
225
9.82
4.25
13.73
32
8.04
4.60
11.20
25
4.91
4.25
6.91
20
3.14
4.00
4.46
16
2.01
3.80
2.87
14
1.54
3.70
2.21
16
2.01
14
1.54
7.00
6.30
5.80
5.40
-
6.90
6.20
5.70
5.30
5.10
2.69
2.73
2.76
2.78
-
2.07
2.10
2.14
2.14
2.16
As(cm )
main RC
32
25
20
16
14
32
25
20
16
14
232
16.08
7.80
20.65
-
25
20
4.91
3.14
as (cm)
7.45
7.80
7.45
7.20
6.75
6.50
6.00
FLEXURAL CAPACITY Ms (tm/m)
12.85
10.48
6.48
4.31
6.58
4.24
4.28
225
9.82
32
8.04