METHOD: Fluorescent AC Yoke with Water based Wet continuous method TEST PROCEDURE: SE 709 (ASME) REPORT NO :16810 INS.ORDER NO.: 20634 CURRENT USED: AC POWDER: Fluorescent Observation Remarks
DATE: 27/10/11 EQUIPMENT: SIMS Yoke SENSITIVITY: 2 mm Date : 03/12/10 Sl.No Specimen 1. Roller SL 05 Qty: 1 No Roller SL 06 Qty: 1 No Roller SL 07 Qty: 1 No Roller SL 08
2.
3.
4.
Group of air cracks observed from 3 locations of circumference Not Acceptable (Longitudinal 4 to 5 cracks in 3 location) Group of air cracks observed from 1 locations of circumference Not Acceptable (Longitudinal 4 to 5 cracks in 1 location) Group of air cracks observed in entire width (200mm) of roller at 3 locations of roller Not Acceptable circumference Deep transverse cracks noticed in entire width 200mm of roller at 3 locations of roller Not Acceptable circumference. Visually also noticed the same. Technical Level: II For Scaanray Metallurgical Services,
S.Balachandar S.Balu Alaganan V.Muthumanickam
Date: M. NAKKEERAN