http://www.pumpworld.com/Calculating_tdh_suction_lift.htm
Suction Lift
Pump Centrifugal Pump Flow Calculato Lift Pump
Home Suction Lift Application
Table of Contents Order Tutorials Pump Store Seminars TDH Calculator Tutorials Chemical Charts Manufacturers Pump Distributors Industry Links Advertise About Us Contact
100 GPM of Water at 170 F Flooded Suction Suction Lift Find the Total Dynamic Head (TDH) TDH = Total Discharge Head + Total Suction Lift Suction Total Suction Lift= Static + Friction Suction Static Lift---------------------------------------- 15' Friction Suction Side Total Length of 3" Pipe----------------------35' (1) 90 deg 3" Elbow = 7.7' of Pipe----------7.7' Go To Fittings Chart --> Total Equivalent Length of 3" Pipe---------42.7' Friction = 4.96 x 42.7 / 100------------- 2.1' See Friction Drop Chart --> Total Suction Lift = 15'(Static) + 2.1'(Friction) = 17.1'
Hydraulic Lifts
www.Alibaba.com Supplies Made to Order from World's Largest Supplier Base. Top Deals!
Discharge Total Discharge Head = Static + Friction Discharge Static Head--------------------------------------22' Friction Discharge Side Total Length of 2" Pipe------------------------142'
Centrifugal Pumps
www.superflowpum capacity from 3 to 1250 m3/hr Head 0.1 bar to 15 bar,
1 of 2
9/17/2013 9:27 PM
http://www.pumpworld.com/Calculating_tdh_suction_lift.htm
(4) 90 deg 2" Elbow = 20.8(4x5.2)of Pipe---20.8' Go To Fittings Chart --> Total Equivalent Length of 2" Pipe ----------162.8' Friction = 35.8 x 162.8/100-----------------58.3' See Friction Drop Chart -->
Total Discharge Head = 22'(Static) + 58.3'(Friction) = 80.3' Total Dynamic Head = Total Discharge Head + Total Suction Head= 80.3' + 17.1' = 97.4'
Send mail to webmaster@pumpworld.com with questions or comments about this web site. Copyright 1997-2012 Pump World
2 of 2
9/17/2013 9:27 PM