Professional Documents
Culture Documents
Alcoa Fujikura Ltd. Routine Inspection and Test Plan For Stainless Steel in Pipe Optical Ground Wire
Alcoa Fujikura Ltd. Routine Inspection and Test Plan For Stainless Steel in Pipe Optical Ground Wire
Receive raw materials Fiber None Check for damage and quantity 100 % N/A Receiving
Receive raw materials Stainless steel None Check for damage, dimensions,
condition and quality
100 % N/A Receiving
SST
Fiber Prep
Fiber color
&striping
Color and stripes
Fiber ID
Level wind
Length (OTDR)
SPC-2-10-212
OPT-3-10-051
100%
100%
N/A
0.01dB/km
Fiber Prep
and SST
SST
Stainless steel
loose tube unit
Attenuation (OTDR)
SS Tube Diameter
Gel fill
Fiber overlength
Weld quality
OPT-3-10-051
OPT-3-10-053
OPT-3-10-387
Eddy current
100 %
OSE AND ISE
OSE
OSE
100%
0.01 dB/km
0.01 mm
+/- 5%
+/-0.05%
N/A
SST
*SST IN PIPE
*(This section pertains to SST in a
Pipe Only)
Stainless steel
tube in pipe
Pipe integrity
Pipe weld projection
Pipe inner diameter
Pipe outer diameter
Fiber overlength
Attenuation (OTDR)
Eddy current
OPT-3-10-080
OPT-3-10-080
OPT-3-10-080
OPT-3-10-387
OPT-3-10-051
100 %
OSE and ISE
OSE and ISE
OSE and ISE
OSE
100% of pipes going to
offsite strander
N/A
0.01 mm
0.01 mm
0.01 mm
+/- 0.5%
0.01dB/km
Pipe
SST
Pipe/ Fiinal
QC
Final Inspection
Finished Product Attenuation (OTDR)
Dimensional checks :
Cable core
Wire preform
Check in-process data
OPT-3-10-051
Pipe Resistance per
OPT-3-10-289
Visual inspection
Verify that all inspections have
been performed and meet
specifications.
100 % bi-directional
OSE and ISE
OSE and ISE
100%
0.01 dB/km
Final QC
Document Number:OPT-2-10-439 Revision: 1 Originator: Tim Hartpence Effective:10/31/2001
Alcoa Fujikura Ltd.
Telecommunications Division
Routine Inspection and Test Plan for Stainless Steel In Pipe Optical Ground Wire
a