PROSEDURE PENGUKURAN PCS 1900 BERDASAR PADA PM 30

TAHAPAN PENGUKURAN

Tujuan pembagian ini untuk meminimisasi error pengukuran SPA yang dipengaruhi oleh dynamic range SPA.

METODA PENGUKURAN
1. 1.1 1.2 2. 2.1 2.2 Over the air (daily operational BALMON)*. In band PCS 1900 over the air Out band PCS 1900 over the air Di dalam shelter (sesuai dengan PM30)**. In band PCS 1900 in shelter Out band PCS 1900 in shelter

Note : *Hasil pengukuran 79 dBc. **Hasil pengukuran 79 dBc untuk 20 Watt & -47 dBm untuk > 20 watt.

1.1 PENGUKURAN IN BAND OVER THE AIR

Perangkat Antenna YAGI Flexible cable Adapter connector SPA (incl pre amp)

Connector N - Female N Male / N - Male N Female to N - Female N - Female

Spesifikasi Min 15 dB 3 meter

Jumlah 1 2 1 1

1.1 CONTOH HASIL PENGUKURAN IN BAND

Setting Frequency center Span RBW Internal ATT Reference level

Keterangan 1980 MHz 20 MHz 100 KHz 0 -10 dBm

Result in Band : peak search marker - 23.85 dBm

Meas set up

Average - trace

1.2 PENGUKURAN OUT BAND OVER THE AIR

Perangkat Antenna YAGI Flexible cable Filter UMTS 2100 SPA (incl pre amp)

Connector N - Female N Male / N - Male N Female to N - Female N - Female

Spesifikasi Min 15 dB 3 meter

Jumlah 1 2 1 1

1.2 RESPONSE FILTER UNTUK PENGUKURAN OUT BAND

Insertion loss pada frequncy 1980 MHz = -3.6 dB

1.2 CONTOH HASIL PENGUKURAN OUT BAND

Setting Frequency center Span RBW Internal ATT Internal pre Amp Reference level

Keterangan 1980 MHz 20 MHz 100 KHz 0 ON -40 dBm

Result out Band : Level pada frequency 1980 MHz - 105.43 dBm

Meas set up

Average - trace

ANALISA PENGUKURAN OVER THE AIR


PENGUKURAN IN BAND = A OUT BAND = B LOSS FILTER = C HASIL -23.85 dBm -105.43 dBm 3.6 dB

TOTAL EMISI = A B - C

78 dBc

SARAN HASIL PENGUKURAN

PART
Increase level in band Increase rejection filter Reduce Insertion loss filter

SPESIFIKASI
Min 50 dB Max 1 dB

2.1 PENGUKURAN IN BAND IN SHELTER

Perangkat Tapper Flexible cable Adapter connector Adapter connector Attenuator Dummy Load SPA (incl pre amp)

Connector N - Female N Male / N - Male N Female to N - Female DIN Male to N - Female N Male to N - Female N Male N - Female

Spesifikasi 10 dB 3 meter

Jumlah 1 3 1 1

40 dB 20 watt 100 watt

1 1 1

2.1 SETTING PENGUKURAN IN BAND IN SHELTER


PART Insertion loss tapper & attenuator Frequency center Span RBW Internal ATT Reference level Meas set up Marker peak search Analisa in band KETERANGAN 56 dB (A) 1980 MHz 20 MHz 100 KHz 0 dB (*) -10 dBm (*) Max hold - trace (B) C = B + A ( 32 dBm ) C > 32 dBm option -47 dBm.

2.2 PENGUKURAN OUT BAND IN SHELTER

Perangkat Tapper

Connector N - Female

Spesifikasi 10 dB

Jumlah 1

Flexible cable
FIlter UMTS 2100 Adapter connector Attenuator Dummy Load SPA (incl pre amp)

N Male / N - Male
N Female to N - Female DIN Male to N - Female N Male to N - Female N Male N - Female

3 meter
IL = 1 dB; Rejection 40 dB

3
1 1

40 dB 20 watt 100 watt

1 1 1

2.2 SETTING PENGUKURAN OUT BAND IN SHELTER


PART Insertion loss tapper & attenuator Frequency center Span RBW Internal ATT Reference level Meas set up KETERANGAN 56 dB (A) 1980 MHz 20 MHz 100 KHz 0 dB (*) -50 dBm (*) Max hold - trace

Internal Pre Amp


Level result frequency 1980 MHz Analisa Out band

ON
(D) E=D+A > 20 watt E = -47 dBm 20 watt ( C E ) 79 dBc

ANALISA PENGUKURAN OVER THE AIR


PENGUKURAN IN BAND OUT BAND HASIL C D

EMISSION TRESHOLD
OPTION 1 C 32 dBm OPTION 2 C < 32 dBm C D 79 dBc Max value D = -47 dBm