BLD-1 Sub Contractor
15
ABN 98 000 893 667
16
LEIGHTON CONTRACTORS PTY LTD
STEELWORK NOTES:
A
1. REFER DRG Z24051 FOR GENERAL AND STEELWORK NOTES 2. ALL EXTERNAL AND EXPOSED STEELWORK TO BE HOT-DIP GALVANISED INCLUDING EXPOSED RAFTERS, BRACING AND COLUMNS IN EXTERNAL UNDERCROFT AREAS. 3. PROVIDE FLY BRACING TO ALL RAFTERS AND UB SECTION COLUMNS AT 3.0m CENTRES TYPICALLY U.N.O. 4. BASE FIXINGS - ALLOW FOR 4min x CAST-IN HOLD DOWN BOLTS TO EACH COLUMN (xC). ALLOW FOR 2min x CHEMSET ANCHORS TO EACH MULLION (xM). 5. ALL RAFTERS TO BE SPLICED AT 18m MAXIMUM LENGTH OR AT LOCATIONS AS INDICATED ON THE DRAWINGS. SPLICE TO BE FULL MOMENT BOLTED SPLICE CONNECTIONS. 6. ALL RAFTER/ UB COLUMN CONNECTIONS TO BE BOLTED END PLATE MOMENT CONNECTIONS. 7. DESIGN IS BASED ON THE FOLLOWING SHEETING PROFILES: - ROOF SHEETING - TRIMDEK 0.48BMT - CREST FASTENED WITH CYCLONIC WASHERS IN ACCORDANCE WITH MANUFACTURERS SPECIFICATION. - WALL CLADDING SPANDEK 0.48BMT VALLEY FASTENED. 8. WALL STUD FRAMING IS SHOWN INDICATIVELY ONLY AND IS TO BE DESIGNED AND CERTIFIED BY OTHERS. 9. STUDS TO BE DESIGNED TO THE WINDLOAD CRITERIA AS SPECIFIED IN THE GENERAL NOTES ON DWG Z24051. WINDLOADING TO BE CALCULATED IN ACCORDANCE WITH AS1170.2. 10. WALL STUDS - MAXIMUM DEFLECTION CRITERIA UNDER V25 WIND SPEED HEIGHT/240 11. MINIMUM STUD BASE METAL THICKNESS 1.5mm.
Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au
BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers
OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au
Darwin Australia
FA A FA
FR B FR
FI N FI
FC F FC
AB CA AB NA
DEPT NAME
SIGNATURE
2
REV
BN
CA
CB
CC
CD
CE
CF
CG
L290-DS-PAE-10112.001
PURCHASER ORDER NO - SERIAL NO
CTR DOC NO
V-31D1-BLD-1-A24120
2 aC
2 aC
aS1(u)
2 aC
2 aC
2 aC
aS1(u)
2 aC
2 aC
35
2-aVB2(u)
2-aVB2(u)
CH
F
1 aC 4 aC 4 aC 4 aC 4 aC 4 aC 1 aC 5 aC
aT1
aR3
33
aP7
R aB 2 aB R2
1 aC
4 aC
1 aC
aS3 aR3
5 aC
BM
1
31
A24130
aS3
AA A NO
ISSUE PURPOSE
1 aC
EK ND O 1B
NG MI A R B F C4 A a SL
REVISIONS
1 aC 5 aC
aR3
29
aP7 3000
aS3
F RE
ER
A G. W D
1 aC
aS4
0 10 24
R FO
L AL
L VE E L
aP2
4 aC
1 aC
aR3
27
SCALE COMPANY CONTRACT NO
1 : 100 2
LEICON REV
REVIEW CLASS
aS3
LEIGHTON DWG NO
Q1447-V-31D1-BLD-1-A24120
1 aC 4 aC 1 aC
AA
SIZE
aR3
5 aC
JKC DWG NO
25
14
V-31D1-BLD-1-A24120
COMPANY DWG NO
A1
COY REV
L290-DS-PAE-10112.001 15 16
10
11
12
13
14
BLD-1 Sub Contractor
15
ABN 98 000 893 667
16
LEIGHTON CONTRACTORS PTY LTD
04
A
05
bR 3
06
bR 3
07
bR 3
01
11
B24131
02
03
bR 3
INTERNAL VERTICAL
TOP CHORD
08
CL. TOP CHORD 2600
bR 3
09
bS3
bR 3
10
bS3
bR 3
11
Architect
Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au
bS3
bH 5
BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers
bR 3
bR 3
bS3 bM1(b)
bS3
bR 3
bR 4
bS1
bS1
bR 3
bC8
bC1
bC1
bC4
bC1
B4 bV
bC1
B4 bV
bH 1
bC1
bC10
TR1 TRUSS
OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au
bR 4
B4 bV
bV B
bH 1
Darwin Australia
LEVEL 00
LEVEL 00
FA A FA
FR B FR
FI N FI
FC F FC
AB CA AB NA
1
B24120
Approval or review hereunder shall not be construed to relieve Vendor / Subcontractor of his responsibilities and liability under the Contract.
1 : 100
SECTION
1 : 100
5
B24120
DEPT NAME
SIGNATURE
04
INTERNAL VERTICAL
bR 3
05
bR 3
06
bR 3
07 08 09
bS 3
0-6037-2
REVIEW CLASS
2
REV
D
2600
10
hOR1
11
bS 3
L290-DS-CSD-10005.001
PURCHASER ORDER NO - SERIAL NO
TOP CHORD
CTR DOC NO
bR 3
V-31D1-BLD-1-B24130
bR 4
bR 4
hOR1
bH 3 bS 3
bC8
E
bM3 bC6 bM3 bC6
LEVEL 00
bC8
DIAGONALS
TR2 TRUSS
LEVEL 00 VEHICLES
STEELWORK NOTES:
F
1. REFER DRG Z24051 FOR GENERAL AND STEELWORK NOTES 2. ALL EXTERNAL AND EXPOSED STEELWORK TO BE HOT-DIP GALVANISED INCLUDING EXPOSED RAFTERS, BRACING AND COLUMNS IN EXTERNAL UNDERCROFT AREAS. 3. PROVIDE FLY BRACING TO ALL RAFTERS AND UB SECTION COLUMNS AT 3.0m CENTRES TYPICALLY U.N.O. 4. BASE FIXINGS - ALLOW FOR 4min x CAST-IN HOLD DOWN BOLTS TO EACH COLUMN (xC). ALLOW FOR 2min x CHEMSET ANCHORS TO EACH MULLION (xM). 5. ALL RAFTERS TO BE SPLICED AT 18m MAXIMUM LENGTH OR AT LOCATIONS AS INDICATED ON THE DRAWINGS. SPLICE TO BE FULL MOMENT BOLTED SPLICE CONNECTIONS. 6. ALL RAFTER/ UB COLUMN CONNECTIONS TO BE BOLTED END PLATE MOMENT CONNECTIONS. 7. DESIGN IS BASED ON THE FOLLOWING SHEETING PROFILES: - ROOF SHEETING - TRIMDEK 0.48BMT - CREST FASTENED WITH CYCLONIC WASHERS IN ACCORDANCE WITH MANUFACTURERS SPECIFICATION. - WALL CLADDING SPANDEK 0.48BMT VALLEY FASTENED. 8. WALL STUD FRAMING IS SHOWN INDICATIVELY ONLY AND IS TO BE DESIGNED AND CERTIFIED BY OTHERS. 9. STUDS TO BE DESIGNED TO THE WINDLOAD CRITERIA AS SPECIFIED IN THE GENERAL NOTES ON DWG Z24051. WINDLOADING TO BE CALCULATED IN ACCORDANCE WITH AS1170.2. 10. WALL STUDS - MAXIMUM DEFLECTION CRITERIA UNDER V25 WIND SPEED HEIGHT/240 11. MINIMUM STUD BASE METAL THICKNESS 1.5mm.
SECTION
1 : 100
2
B24120
SECTION
1 : 100
6
B24121
04
bR 2
05
bR 3
06
bR 3
07
bR 4
08
bS3 1500 CL. TOP CHORD
3
hOR1
09
bS 3
10
hOR1
bH 3
END VERTICAL
BTM. CHORD
END VERTICAL
bS
11
bS 3
INTERNAL VERTICAL
bS1
TOP CHORD
BTM. CHORD
TR2 TRUSS
bH 3 bS 3
bM3
H
STEEL FRAMING SCHEDULE. MARK DESCRIPTION
BRACING bBR1 bBR4 bVB1 bVB2 bVB4 bVB5 COLUMNS bC1 bC2 bC4 bC6 bC7 bC8 bC9 bC10 bM1 bM2 bM3 HEADS bH4 bH5 OUTRIGGERS hOR1 RAFTERS bR2 bR3 bR4 bR5 STRUTS bS1 bS3 30mm DIA. CROSS ROD BRACING 75x8.0 EA CROSS BRACING 30mm DIA. VERT. CROSS ROD BRACING 75x8.0 EA 150x5.0 SHS 100x8.0 EA VERT. CROSS BRACING 150x5.0 SHS 125x5.0 SHS 200x6.0 SHS 250UC73 310UB46 200UC60 200x5.0 SHS 200x9.0 SHS 150x9.0 SHS 150x50x4.0 RHS 150x100x4.0 RHS 200x6.0 SHS 250 PFC 250PFC
JGC JOB CODE KBR JOB CODE CHD JOB CODE
LEVEL 00
LEVEL 00 VEHICLES
AA NO 11-APRIL-13 TENDER ISSUE DATE ISSUE PURPOSE SWS CKD DDG APP
bC6
bM3
bC6
bH 3
bS
bS
bR3
REVISIONS
SECTION
1 : 100
3
B24120
SECTION
1 : 100
7
B24121
05
bR 3
06
bR 3
07
bR 3
08
09
bS 1
10
hOR1
11
bS 3
hOR1
bS
bS
bS3
bS3
bR5
CENTRAL CONTROL BUILDING STRUCTURAL BUILDING SECTIONS - EPC BUILDING WORKS - SHEET 1
bS
bC1
bC1
bC1
bC1
bC4
bC4
B bV
bC2
bV B
bH 1
bV
B4
1 : 100 2
LEICON REV
REVIEW CLASS
LEVEL 00
LEVEL 00 VEHICLES
LEIGHTON DWG NO
Q1447-V-31D1-BLD-1-B24130
JKC DWG NO
AA
SIZE
SECTION
1 : 100
4
B24120
SECTION
1 : 100
8
B24121
V-31D1-BLD-1-B24130
COMPANY DWG NO
A1
COY REV
L290-DS-CSD-10005.001 13 14 15 16
7 8 9
10
11
12
6
PURLIN & GIRT SCHEDULE
bG1 bG2 bP1 bP2 bP3 bP4 bT1 bT2 Z20024 GIRTS AT 900 VERT. CTRS. + 1 ROW OF BRIDGING Z20019 GIRTS AT 900 VERT. CTRS. + 1 ROW OF BRIDGING Z25024 PURLINS AT 300 MAX. CTRS. + 2 ROWS OF BRIDGING Z25024 PURLINS AT 450 MAX. CTRS. + 2 ROWS OF BRIDGING Z25019 PURLINS AT 450 MAX. CTRS. + 1 ROW OF BRIDGING Z25024 PURLINS AT 900 MAX. CTRS. + 1 ROWS OF BRIDGING C25024 TRIMMER PURLIN C25015 TRIMMER PURLIN
8
STEEL FRAMING SCHEDULE MARK DESCRIPTION
BRACING bBR1 bBR4 bVB1 bVB2 bVB4 bVB5 30mm DIA. CROSS ROD BRACING 75x8.0 EA CROSS BRACING 30mm DIA. VERT. CROSS ROD BRACING 75x8.0 EA 150x5.0 SHS 100x8.0 EA VERT. CROSS BRACING
10
STEEL FRAMING SCHEDULE MARK DESCRIPTION
COLUMNS bC1 bC2 bC4 bC6 bC7 bC8 bC9 bC10 bM1 bM2 bM3 150x5.0 SHS 125x5.0 SHS 200x6.0 SHS 250UC73 310UB46 200UC60 200x5.0 SHS 200x9.0 SHS 150x9.0 SHS 150x50x4.0 RHS 150x100x4.0 RHS
11
12
STEEL FRAMING SCHEDULE MARK DESCRIPTION
13
14
BLD-1 Sub Contractor
15
ABN 98 000 893 667
16
LEIGHTON CONTRACTORS PTY LTD
NOTE:
A
FIRE SEPERATION REQUIREMENTS AND ASSOCIATED IMPACTS ON STRUCTURAL FRAMING STILL TO BE RESOLVED
HEADS bH4 bH5 OUTRIGGERS hOR1 RAFTERS bR2 bR3 bR4 bR5
Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au
NOTE:
TR1 & TR2 - REFER SECTIONS ON DWG B24130
BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers
OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au
G
10
H
10
8
B24130
7
B24130
6
B24130
L
TYP. EAVE PURLIN U.N.O. TO BE PROVIDED IN EACH BAY
Darwin Australia
FA A FA
FR B FR
FI N FI
FC F FC
AB CA AB NA
9 bC
bC
bVB5
bM
bC
hOR1
11
TYP. 3500 hOR1
bM 3
bH5
bH5
bP2
bP3
bP1
bP1
bM
hOR1
1
bH4 bS1 bS1 B24140
4 bC
bS3
4 bC
bS3
6 bC
bS3
6 bC
bS3
6 bC
bS3
7 bC
DEPT NAME
SIGNATURE
bB
bP1
R4
R bB
bB
R4
R4 bB
bB R4
1 bC
1 bC
bC
10
bVB2
bVB2
2
REV
hOR1
D
bP2 TYP. EAVE PURLIN U.N.O. TO BE PROVIDED IN EACH BAY
4 bC
1 R bB
bB R1
R1 bB
bB R1
10
7 bC
CPY DOC NO
L290-DS-PAE-10102.002
PURCHASER ORDER NO - SERIAL NO
bS1
2 bC
CTR DOC NO
bS1
bS3
bS3
bS1
V-31D1-BLD-1-B24121
bP1
bS1
bS1
bP2
3000
bB R4
bVB2
bR3
bR3
bR5
bR5
bR3
1 bC
1 bC 10 bC bM 2
hOR1
R1 bB
bB R
bB R
bB R1
R1 bB
bB R1
R1 bB
bB R1
bR5
bB R4
4 BR
bB R4
bVB4
bH4
TYP.
bP1
bH4
R4 bB
R1 bB
R1 bB
9
B24131
4 bC
R bB 1
bS1
bS1
bS3
bS3
bS1
7 bC
09
bS1
bS1
bP1
bM
2 4 bC
bS3 bVB1
4 bC
bS3
R4 bB
1 bC
bB R4
bB R4
1 bC
bM
1
R1 bB bB R1
9 bC
hOR1
1 bC
bS1
1 bC
bBR
b BR 1
bS3
bM 1
6 bC
bS3
6 bC
bS3
6 bC
bVB2
7 bC
bB R1
R bB
bB R1
hOR1
hOR1
hOR1
hOR1
hOR1
TYP.
3500
bP2
bP1
hOR1
bH4
R4 bB
bS3
08
3
bM
R4 bB
bB R4
bB R4
1 bC
bM
2 0
R4 bB
bR3
1 bC
hOR1
07
10
B24131
R4 bB
bB R4
bB R4
1 bC
bVB4
bH4
bS1
bS1
AA A NO
ISSUE PURPOSE
R4 bB
bR3
1 bC
10 bC hOR1
REVISIONS
06
12
B24132
bP1
STEELWORK NOTES:
1. REFER DRG Z24051 FOR GENERAL AND STEELWORK NOTES 2. ALL EXTERNAL AND EXPOSED STEELWORK TO BE HOT-DIP GALVANISED INCLUDING EXPOSED RAFTERS, BRACING AND COLUMNS IN EXTERNAL UNDERCROFT AREAS. 3. PROVIDE FLY BRACING TO ALL RAFTERS AND UB SECTION COLUMNS AT 3.0m CENTRES TYPICALLY U.N.O. 4. BASE FIXINGS - ALLOW FOR 4min x CAST-IN HOLD DOWN BOLTS TO EACH COLUMN (xC). ALLOW FOR 2min x CHEMSET ANCHORS TO EACH MULLION (xM). 5. ALL RAFTERS TO BE SPLICED AT 18m MAXIMUM LENGTH OR AT LOCATIONS AS INDICATED ON THE DRAWINGS. SPLICE TO BE FULL MOMENT BOLTED SPLICE CONNECTIONS. 6. ALL RAFTER/ UB COLUMN CONNECTIONS TO BE BOLTED END PLATE MOMENT CONNECTIONS. 7. DESIGN IS BASED ON THE FOLLOWING SHEETING PROFILES: - ROOF SHEETING - TRIMDEK 0.48BMT - CREST FASTENED WITH CYCLONIC WASHERS IN ACCORDANCE WITH MANUFACTURERS SPECIFICATION. - WALL CLADDING SPANDEK 0.48BMT VALLEY FASTENED. 8. WALL STUD FRAMING IS SHOWN INDICATIVELY ONLY AND IS TO BE DESIGNED AND CERTIFIED BY OTHERS. 9. STUDS TO BE DESIGNED TO THE WINDLOAD CRITERIA AS SPECIFIED IN THE GENERAL NOTES ON DWG Z24051. WINDLOADING TO BE CALCULATED IN ACCORDANCE WITH AS1170.2. 10. WALL STUDS - MAXIMUM DEFLECTION CRITERIA UNDER V25 WIND SPEED HEIGHT/240 11. MINIMUM STUD BASE METAL THICKNESS 1.5mm.
DRAWING TITLE
R4 bB
bB R4
bB R4
9 bC bM 2
CENTRAL CONTROL BUILDING - ROOF STEELWORK FRAMING PLAN - EPC BUILDING WORKS - SHEET 2
R4 bB
bR3
9 bC
hOR1
1 bC
05
bS1
bS1
bM
1 : 100 2
LEICON REV
REVIEW CLASS
R4 bB
bB R4
9 bC
LEIGHTON DWG NO
bR2 bVB5
1 bC
Q1447-V-31D1-BLD-1-B24121
JKC DWG NO
AA
SIZE
hOR1
bVB5
04
V-31D1-BLD-1-B24121
COMPANY DWG NO
A1
COY REV
L290-DS-PAE-10102.002 15 16
6
PURLIN & GIRT SCHEDULE
bG1 bG2 bP1 Z20024 GIRTS AT 900 VERT. CTRS. + 1 ROW OF BRIDGING Z20019 GIRTS AT 900 VERT. CTRS. + 1 ROW OF BRIDGING Z25024 PURLINS AT 300 MAX. CTRS. + 2 ROWS OF BRIDGING Z25024 PURLINS AT 450 MAX. CTRS. + 2 ROWS OF BRIDGING Z25019 PURLINS AT 450 MAX. CTRS. + 1 ROW OF BRIDGING Z25024 PURLINS AT 900 MAX. CTRS. + 1 ROWS OF BRIDGING C25024 TRIMMER PURLIN C25015 TRIMMER PURLIN
8
STEEL FRAMING SCHEDULE MARK DESCRIPTION
BRACING bBR1 bBR4 bVB1 bVB2 bVB4 bVB5 30mm DIA. CROSS ROD BRACING 75x8.0 EA CROSS BRACING 30mm DIA. VERT. CROSS ROD BRACING 75x8.0 EA 150x5.0 SHS 100x8.0 EA VERT. CROSS BRACING
10
STEEL FRAMING SCHEDULE MARK DESCRIPTION
COLUMNS bC1 bC2 bC4 bC6 bC7 bC8 bC9 bC10 bM1 bM2 bM3 150x5.0 SHS 125x5.0 SHS 200x6.0 SHS 250UC73 310UB46 200UC60 200x5.0 SHS 200x9.0 SHS 150x9.0 SHS 150x50x4.0 RHS 150x100x4.0 RHS
11
12
STEEL FRAMING SCHEDULE MARK DESCRIPTION
13
14
BLD-1 Sub Contractor
15
ABN 98 000 893 667
16
LEIGHTON CONTRACTORS PTY LTD
NOTE:
A
FIRE SEPERATION REQUIREMENTS AND ASSOCIATED IMPACTS ON STRUCTURAL FRAMING STILL TO BE RESOLVED
NOTE:
REFER TO DWG B24121 FOR STEELWORK NOTES.
HEADS bH4 bH5 OUTRIGGERS hOR1 RAFTERS bR2 bR3 bR4 bR5
Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au
NOTE:
TR1 & TR2 - REFER SECTIONS ON DWG B24130
BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers
OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au
A
bM 2 10 bC
B
10 bC
C
9 bC
5
B24130
E
2 2
G
10 bC 3
Darwin Australia
11
C
10 bC
9 bC
bM
bM
9 bC
bVB5
bM
FA A FA
FR B FR
FI N FI
FC F FC
AB CA AB NA
bH5
bH5
bH5
bH5
bH5
bH5
bB R4
R bB
bB R4
R4 bB
bB R4
R4 bB
bB R4
R4 bB
bB R4
bB
R4
bB
R4
R4 bB
DEPT NAME
SIGNATURE
bS3
bVB4
bS3
bS1
bS1
bS1
bS1
bH4
bS1
bB
R4
R bB
bB
bS1
R4 bB
R4
R4 bB
10
D
TYP. EAVE PURLIN U.N.O. TO BE PROVIDED IN EACH BAY
10 bC
1 bC
bR3
1 bC
1 bC
9 bC
bR3
1 bC
1 bC
2
REV
hOR1
CPY DOC NO
L290-DS-PAE-10102.001
PURCHASER ORDER NO - SERIAL NO
CTR DOC NO
V-31D1-BLD-1-B24120
bB R4
E
9
B24131
09
1 bC
1 bC
bR3
1 bC
1 bC
1 bC
bR3
1 bC
1 bC
hOR1
08
1 bC
1 bC
bR3
1 bC
1 bC
1 bC
bR3
1 bC
1 bC
hOR1
bH4
B24130
B24130
B24130
B24130
bM
2 9 bC 1 bC bR3 8 bC
10
B24131
07
bR3 bR4(u)
8 bC
8 bC
bR4
1 bC
bR3
1 bC
hOR1
bVB4
bH4
bS1
bS1
bB R4
R bB
bB R4
R1 bB
1 bC bR3
bB R
R1 bB
bB R1
bS3
R4 bB
1 bC
bB R4
1 bC
bS1
bB R4
bM
2
R bB 4
1
bB R4
4
R4 bB
bB R4
bB R4
R bB
bB R4
R4 bB
bB R4
bB R4
R4 B b
R4 bB
R4 bB
bB R4
bB R4
bB R4
bB R4
R4 bB
bB R4
R4 bB
bB R4
bB R4
R4 bB
bB R4
bVB4
bH4
bS1
bS1
bS3
bS1
bS1
bS3
bVB4
bS3
bS1
ISSUE PURPOSE
12
B24132
06
9 bC
bS3(u)
bR3
bS3(u)
bS3(u)
bR3
bS3(u)
bS3(u)
bR3
1 bC
REVISIONS
hOR1 bP4 4000 TR1 TR2 TR2 bVB4 bH4 bS1 bS3 bP3 bP4 bP4
05
J
9 bC
1 bC bR3
bS3(u)
bR3
bS3(u)
bS3(u)
bR3
bS3(u)
bS3(u)
1 bC
bR3
1 bC
9 bC bM 2
hOR1
bB R4
bB
R4
bB R4
R1 bB
bB R
R4 bB
bB R4
CENTRAL CONTROL BUILDING - ROOF STEELWORK FRAMING PLAN - EPC BUILDING WORKS - SHEET 1
bH4
bS1
bS1
bS3
bS1
bM
2
COMPANY CONTRACT NO
SCALE
1 : 100 2
LEICON REV
REVIEW CLASS
R4 bB
bB R4
R1 bB
1 bC bR3 8 bC
bB R
R1 bB
bB R1
R4 bB
8 bC 1 bC 1 bC
bB R4
9 bC
LEIGHTON DWG NO
04
9 bC
bR4(u) bR3
8 bC
bR4(u) bR3
bR2 bVB5
hOR1
Q1447-V-31D1-BLD-1-B24120
JKC DWG NO
AA
SIZE
hOR1
bVB5
V-31D1-BLD-1-B24120
COMPANY DWG NO
A1
COY REV
L290-DS-PAE-10102.001 15 16
10
11
12
13
14
BLD-1 Sub Contractor
15
ABN 98 000 893 667
16
LEIGHTON CONTRACTORS PTY LTD
CA
CB
CC
CD
CE
CF
CG
aR3
aR3
B
aR3
C
LEVEL 00
ELEVATION ON GRID 01
D
WAREHOUSE PURLIN & GIRTS SCHEDULE
aG1 aG2 aG3 aP1 aP2 aP3 aP4 aP5 aP6 aP7 aT1 aT2 Z20019 AT 750 MAX CTRS + 1 ROW BRIDGING Z20024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20019 AT 1500 MAX CTRS + 1 ROW BRIDGING Z25019 AT 750 MAX CTRS + 1 ROW BRIDGING Z25024 AT 1500 MAX CTRS + 1 ROW BRIDGING Z25019 AT 1500 MAX CTRS + 1 ROW BRIDGING Z25024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20019 AT 750 MAX CTRS + 1 ROW BRIDGING C20015 TRIMMER PURLIN C25019 TRIMMER PURLIN SCALE 1 : 100 at A1.
BEAMS aB1 aB2 BRACING aBR1 aBR2 aVB1 aVB2 COLUMNS aC1 aC2 aC3 aC4 aC5 aC6 HEADS aH1 aH2 aH3 aH4 aH5 MULLIONS aM1 aM2 aM3 aM4 RAFTERS aR1 aR2 aR3 aR4 STRUTS aS1 aS2 aS3 aS4
460UB82 310UB46 125x8.0 EA 20mm DIA. CROSS ROD BRACING 125x8.0 EA VERT. CROSS BRACING 20mm DIA. VERT. CROSS ROD BRACING 610UB101 460UB67 410UB54 200x6.0 SHS 150x5.0 SHS 310UB40 250x150x5.0 RHS (ON FLAT) 150x100x5.0 RHS (ON FLAT) 200x6.0 SHS 150x5.0 SHS 200x100x5.0 RHS (ON FLAT) 200PFC 150x100x4.0 RHS 150x50x4.0 RHS 250PFC 610UB101 460UB67 310UB32 300PFC 150x5.0 SHS 125x5.0 SHS 89x3.5 SHS 200x5.0 SHS
Architect
Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au
BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers
OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au
Darwin Australia
FA A FA
FR B FR
FI N FI
FC F FC
AB CA AB NA
aC3
aC3
aC3
aC3
aC3
aC3
aC3
aH 2
aH 4
DEPT NAME
SIGNATURE
2
REV
L290-DS-PAE-10113.002
PURCHASER ORDER NO - SERIAL NO
CTR DOC NO
V-31D1-BLD-1-A24141
35
33
32
31
29
27
25
23
21
aS1
aS1
aS2
aS2
aS2
aS1
aS1
aH1
B1 aV
aV B1
B1 aV
aV B1
B1 aV
aV B1
B1 aV
aV B1
aS1
aB2 aC1
aB2 aC1
aS 4
aB2 aC1
aB2 aC1
aS 4
aB2 aC1
aM4
aM4
aH4 aM3
aV B1
aH4 aM3
aH4
aH4 aM3
aH4
aH4
aH 4
aM3
aM2
aM3
aM3
aM3
G
LEVEL 00
aH2
aH4
aH4
aH4
ELEVATION ON GRID CA
SCALE 1 : 100 at A1.
21 19
I
aM3
AA NO
ISSUE PURPOSE
SWS CKD
DDG APP
REVISIONS
17
15
13
11
09
07
05
03
01
ICHTHYS ONSHORE LNG FACILITIES
DRAWING TITLE
aV B1
aS1
aS1
aS2
aS2
aS2
aS2
aS2
aS1
aS1
aR 3
aR 3
aR 3
aR 3
aR 3
aR 3
aH5 aC1
aS3
aR 3
aS3 aH5
aC1
aC1
aC1
aC1
aC1
aC1
aC1
aC1
aC1
aM1
aM1
aM1
aM1
aH4
aH4
B aV 1 aV B
aH4
aH4
aH4
aH4
aH4
1 B aV aV B
aH2
SCALE COMPANY CONTRACT NO
aC3
aR 3
1 : 100 2
LEICON REV
REVIEW CLASS
1
JGC JOB CODE KBR JOB CODE CHD JOB CODE
LEVEL 00
LEIGHTON DWG NO
Q1447-V-31D1-BLD-1-A24141
AA
SIZE
ELEVATION ON GRID CA
SCALE 1 : 100 at A1.
JKC DWG NO
V-31D1-BLD-1-A24141
COMPANY DWG NO
A1
COY REV
L290-DS-PAE-10113.002 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
10
11
12
13
14
BLD-1 Sub Contractor
15
ABN 98 000 893 667
16
LEIGHTON CONTRACTORS PTY LTD
CG
CF
CE
CD
CC
CB
CA
aR3
aR3
B
B2 aV
aH 1
aV B2
B2 aV
aV B2
aS1
aS1
aH4
B2 aV
aV B2 B2 aV
aH4
aV B2
LEVEL 00
BEAMS aB1 aB2 BRACING aBR1 aBR2 aVB1 aVB2 COLUMNS aC1 aC2 aC3 aC4 aC5 aC6 HEADS aH1 aH2 aH3 aH4 aH5 MULLIONS aM1 aM2 aM3 aM4 RAFTERS aR1 aR2 aR3 aR4 STRUTS aS1 aS2 aS3 aS4
460UB82 310UB46 125x8.0 EA 20mm DIA. CROSS ROD BRACING 125x8.0 EA VERT. CROSS BRACING 20mm DIA. VERT. CROSS ROD BRACING 610UB101 460UB67 410UB54 200x6.0 SHS 150x5.0 SHS 310UB40 250x150x5.0 RHS (ON FLAT) 150x100x5.0 RHS (ON FLAT) 200x6.0 SHS 150x5.0 SHS 200x100x5.0 RHS (ON FLAT) 200PFC 150x100x4.0 RHS 150x50x4.0 RHS 250PFC 610UB101 460UB67 310UB32 300PFC 150x5.0 SHS 125x5.0 SHS 89x3.5 SHS 200x5.0 SHS
Architect
Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au
BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers
OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au
aH 1
Darwin Australia
FA A FA
FR B FR
FI N FI
FC F FC
AB CA AB NA
aM4
aC2
aM4
aC2
aC2
aC2
aC2
aC2
aC2
DEPT NAME
SIGNATURE
aM3 aM3
aM3
aM3
2
REV
L290-DS-PAE-10113.001
PURCHASER ORDER NO - SERIAL NO
CTR DOC NO
V-31D1-BLD-1-A24140
ELEVATION ON GRID 35
SCALE 1 : 100 at A1.
21
E
01
03
05
07
09
11
13
15
17
19
aS2
aS2
aS2
aS2
aS2
F
aR 3
aV B
aS3 aH5
aR 3
aR 3
aH5 aC1 Z20019 AT 750 MAX CTRS + 1 ROW BRIDGING Z20024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20019 AT 1500 MAX CTRS + 1 ROW BRIDGING Z25019 AT 750 MAX CTRS + 1 ROW BRIDGING Z25024 AT 1500 MAX CTRS + 1 ROW BRIDGING Z25019 AT 1500 MAX CTRS + 1 ROW BRIDGING Z25024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20019 AT 750 MAX CTRS + 1 ROW BRIDGING C20015 TRIMMER PURLIN C25019 TRIMMER PURLIN aM1 aM1
aC1
aC3
aC1
aC1
aC1
aC1
aC1
aC1
aC1
aM1
aM1
aH4
aH4
B aV aV B 1 1
aH4
aH4
aH4
aH4
aH4
aH4
LEVEL 00
ELEVATION ON GRID CG
SCALE 1 : 100 at A1.
19
21
23
25
27
29
31
33
35
aC1
aR 3
aS1
aS1
aS1
aS1
aS1
aR 4
B aV 1
REVISIONS
aS1
aS1
aS1
aS1
aS1
aS1
I
aH1
aR 3 aR 3 aR 3 aR 3 aR 3 aR 3
aS1
aR 3
aR 3
B1 aV
aV B1
B1 aV
aV B1
B1 aV
aV B1
B1 aV
aV B1
aR 4
aC1
aC1
aC1
aC1
aM4
aM1
aM1
aM1
aM1
aH4
aH4
aH4
aH4
aH4
aH aM4 4
aC1
B aV
aC1
aV B
aB1
aB2 aH5
aB2
aB2
aB2
aC2
SCALE
1 : 100 2
LEICON REV
aM3
aM3
aM3
aM3
aM3 aM3
aM3
aM3
aM3
aM3
aM3 aM3
aH4
4 aS
aM3
4 aS
COMPANY CONTRACT NO
REVIEW CLASS
LEVEL 00
LEIGHTON DWG NO
Q1447-V-31D1-BLD-1-A24140
AA
SIZE
ELEVATION ON GRID CG
SCALE 1 : 100 at A1.
JKC DWG NO
V-31D1-BLD-1-A24140
COMPANY DWG NO
A1
COY REV
L290-DS-PAE-10113.001 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
10
11
12
13
14
BLD-1 Sub Contractor
15
ABN 98 000 893 667
16
LEIGHTON CONTRACTORS PTY LTD
CA
CB
CC
aR1 aR2
CD
aS 1
aR1
CE
CF
CG
aR2
B
aR3
C
LEVEL 00
SECTION
1 : 100
4
A24121
BEAMS aB1 aB2 BRACING aBR1 aBR2 aVB1 aVB2 COLUMNS aC1 aC2 aC3 aC4 aC5 aC6 HEADS aH1 aH2 aH3 aH4 aH5 MULLIONS aM1 aM2 aM3 aM4 RAFTERS aR1 aR2 aR3 aR4 STRUTS aS1 aS2 aS3 aS4
460UB82 310UB46 125x8.0 EA 20mm DIA. CROSS ROD BRACING 125x8.0 EA VERT. CROSS BRACING 20mm DIA. VERT. CROSS ROD BRACING 610UB101 460UB67 410UB54 200x6.0 SHS 150x5.0 SHS 310UB40 250x150x5.0 RHS (ON FLAT) 150x100x5.0 RHS (ON FLAT) 200x6.0 SHS 150x5.0 SHS 200x100x5.0 RHS (ON FLAT) 200PFC 150x100x4.0 RHS 150x50x4.0 RHS 250PFC 610UB101 460UB67 310UB32 300PFC 150x5.0 SHS 125x5.0 SHS 89x3.5 SHS 200x5.0 SHS
Architect
Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au
BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers
aS
aS
OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au
Darwin Australia
aC4
FA A FA
FR B FR
FI N FI
FC F FC
AB CA AB NA
aC1
aC1
DEPT NAME
SIGNATURE
2
REV
L290-DS-PAE-10008.002
PURCHASER ORDER NO - SERIAL NO
CTR DOC NO
V-31D1-BLD-1-A24131
CA
CB
CC
1
aR1
CD
aS 1
aR1
CE
1
CF
CG
aS
aS
aS
aS
aR2
aR2
aS
aS
aR3
aR3
aC1
aC4
LEVEL 00
SECTION
1 : 100
5
A24122
aC1
AA NO
ISSUE PURPOSE
SWS CKD
DDG APP
REVISIONS
1 : 100 2
LEICON REV
REVIEW CLASS
LEIGHTON DWG NO
Q1447-V-31D1-BLD-1-A24131
JKC DWG NO
AA
SIZE
V-31D1-BLD-1-A24131
COMPANY DWG NO
A1
COY REV
L290-DS-PAE-10008.002 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
10
11
12
13
14
BLD-1 Sub Contractor
15
ABN 98 000 893 667
16
LEIGHTON CONTRACTORS PTY LTD
CA
A
CB
aR2
CC
aR1
CD
aS 1
aR1
CE
aR2
CF
CG
CH
NOTES:
1. REFER TO DWG. A24120 FOR STEEL MEMBER SCHEDULE
Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au
Architect
aS
aS
BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers
aC4
OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au
B
aR3
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
LEVEL 01 A20011
aB1
aB1
Subcontractor ISSUE PURPOSE: CTR RESULT CODE: X
Darwin Australia
FA A FA
FR B FR
FI N FI
FC F FC
AB CA AB NA
aH 4
aC1
aC4
aC4
aC4
aC4
aC4
aC1
aC5
NEXT STATUS:
aM3
aM3
C
LEVEL 00
aH 4
DEPT NAME
SIGNATURE
aH 2
2
REV
SECTION
D
1 : 100
1
A24100
CPY DOC NO
L290-DS-PAE-10008.001
PURCHASER ORDER NO - SERIAL NO
CTR DOC NO
V-31D1-BLD-1-A24130
CA
E
1
CB
aS
aR2
CC
1
aR1
CD
aS 1
aR1
CE
aS 1
aR2
CF
aS 1
CG
CH
aS
aS
aC6
aC6
aC6
aC6
aS
aS
aS
aS
aR4
aR4
aC6
aS
F
LEVEL 01 A20011
aS
aS
aS
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aB
aC4
aC4
aC4
aC4
aH 4
aM2
aM2
aM2
LEVEL 00
SECTION
H
1 : 100
2
A24121
aH 4
aM2
aC4
aH 5
aS
aR3
AA NO
ISSUE PURPOSE
SWS CKD
DDG APP
REVISIONS
CA
I
CB
CC
1
aR1
CD
aS 1
aR1
CE
1 aS
CF
CG
CH
ICHTHYS ONSHORE LNG FACILITIES
aS
aS
aS
aR2
aR2
aS
aS
DRAWING TITLE
aR3
aC1
aC1
J
aH 4
aC4
aM1 aH4
aH 5
aC5
1 : 100 2
LEICON REV
REVIEW CLASS
LEVEL 00
LEIGHTON DWG NO
Q1447-V-31D1-BLD-1-A24130
JKC DWG NO
AA
SIZE
SECTION
1 : 100
3
A24121
V-31D1-BLD-1-A24130
COMPANY DWG NO
A1
COY REV
L290-DS-PAE-10008.001 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
5
8.
10
11
12
13
14
BLD-1 Sub Contractor
15
ABN 98 000 893 667
16
LEIGHTON CONTRACTORS PTY LTD
GENERAL
1.
FOOTINGS
1. AN ALLOWABLE BEARING PRESSURE IN NATURAL GROUND OF 100 kPa HAS BEEN ASSUMED IN THE DESIGN OF FOOTINGS. THE SUBCONTRACTOR SHALL ENGAGE A REGISTERED GEOTECHNICAL ENGINEER TO VERIFY THAT THE GROUND AT EACH FOOTING IS CAPABLE OF CARRYING THIS PRESSURE. ALL FOOTING EXCAVATIONS SHALL BE CLEANED OF LOOSE MATERIAL AND WATER. ALL FOUNDATION MATERIAL SHALL BE INSPECTED BY THE STRUCTURAL ENGINEER BEFORE ANY CONCRETE IS PLACED. WHERE VERIFIED FOUNDATION MATERIAL IS LOWER THAN THE UNDERSIDE OF FOOTINGS AS DETAILED, BACKFILL ADDITIONAL EXCAVATION WITH GRADE N20 CONCRETE. SIDES OF FOOTINGS SHALL BE FORMED AS NECESSARY WHEN EXCAVATED FACE IS NOT STABLE. ALL WALLS AND COLUMNS SHALL BE CONCENTRIC WITH SUPPORTING FOOTINGS UNLESS OTHERWISE NOTED ON THE DRAWINGS. UNLESS APPROVED BY THE STRUCTURAL ENGINEER, EXCAVATIONS SHALL NOT EXTEND BELOW A LINE DIPPING AT 45 DEGREES AND AWAY FROM THE NEAREST UNDERSIDE CORNER OF ANY FOOTINGS A PRELIMINARY GEOTECHNICAL STUDY FOR THE ORIGINAL SITE HAS BEEN PREPARED BY COFFEY GEOTECHNICS REPORT No. 12128AA-AB AND DATED 5TH FEBRURARY 2013. THE SUBCONTRACTOR SHALL ENSURE THAT THEY ARE FAMILIAR WITH THE CONTENTS OF THIS REPORT. ALL FOOTING EXCAVATIONS SHALL BE MAINTAINED FREE OF WATER BY PROVISION OF RELIEF DRAINS, OR DRAINAGE TO SUITABLE COLLECTION SUMPS FOR REMOVAL BY PUMPING OR MANUAL MEANS. ALL REINFORCING STEEL IS TO BE MANUFACTURED AND SUPPLIED BY ORGANISATIONS CERTIFIED BY ACRS (AUSTRALIAN CERTIFICATION AUTHORITY FOR REINFORCING STEELS LTD) OR AN EQUIVALENT THIRD PARTY PRODUCT CERTIFICATION SYSTEM APPROVED IN WRITING BY THE ENGINEER. EVIDENCE OF COMPLIANCE WITH THIS REQUIREMENT IS TO BE SUPPLIED TO THE ENGINEER. REINFORCEMENT SYMBOLS: RPLAIN ROUND BAR GRADE R250N TO AS 4671 SDEFORMED BAR GRADE D250N TO AS 4671 NDEFORMED BAR GRADE D500N TO AS 4671 SL/RL- DEFORMED WIRE REINFORCING MESH GRADE D500L TO AS 4671 WCOLD DRAWN ROUND WIRE GRADE R500L TO AS 4671 THE NUMBER FOLLOWING THE BAR SYMBOL IS THE NOMINAL BAR DIAMETER IN MILLIMETRES. 24. SPLICES IN REINFORCEMENT SHALL BE MADE ONLY IN THE POSITION SHOWN. WRITTEN APPROVAL BY THE STRUCTURAL ENGINEER SHALL BE OBTAINED FOR ANY OTHER SPLICES. 25. WELDING OF REINFORCEMENT WILL BE PERMITTED ONLY AFTER APPROVAL BY THE STRUCTURAL ENGINEER AND IN ACCORDANCE WITH THE CONCRETE SPECIFICATION. 26. REINFORCEMENT SHALL BE BENT COLD IN ACCORDANCE WITH AS 3600 EXCEPT WHERE APPROVED BY THE STRUCTURAL ENGINEER. NO RE-BENDING SHALL BE PERMITTED UNLESS APPROVED BY THE STRUCTURAL ENGINEER.
STEELWORK
1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS/NZS 1163, 3678, 3679.1, 3679.2 AND AS 4100. ALL STRUCTURAL STEEL IS TO BE MANUFACTURED AND SUPPLIED BY ORGANISATIONS CERTIFIED BY ACRS (AUSTRALIAN CERTIFICATION AUTHORITY FOR REINFORCING STEELS LTD) OR AN EQUIVALENT THIRD PARTY PRODUCT CERTIFICATION SYSTEM APPROVED IN WRITING BY THE ENGINEER. EVIDENCE OF COMPLIANCE WITH THIS REQUIREMENT IS TO BE SUPPLIED TO THE ENGINEER. GP (GENERAL PURPOSE) CATEGORY WELDS SHALL BE USED FOR WELDING OF ALL STRUCTURAL STEELWORK UNLESS NOTED OTHERWISE. ALL WELDS 6 C.F.W. ALL AROUND, UNLESS NOTED OTHERWISE. C.P.B.W. INDICATES COMPLETE PENETRATION BUTT WELD. WELDING SHALL BE PERFORMED BY A QUALIFIED WELDER IN ACCORDANCE WITH AS 1554 PART 1. ALL BOLTS TO BE M20 8.8/S UNLESS NOTED OTHERWISE. PROVIDE 10mm THICK M.S. PLATES THROUGHOUT, UNLESS NOTED OTHERWISE. BOLT TYPES (AND DESIGNATIONS, WHERE USED) SHALL BE AS FOLLOWS: 4.6/S - COMMERCIAL BOLTS TO AS 1111 AND AS 1112 SNUG TIGHTENED. 8.8/S - HIGH STRENGTH STRUCTURAL BOLTS, NUTS AND HARDENED WASHERS TO AS 1252, SNUG TIGHTENED ONLY. 8.8/TF - HIGH STRENGTH STRUCTURAL BOLTS AS ABOVE, FULLY TENSIONED TO AS 1511 IN FRICTION TYPE JOINT AND UNLESS NOTED OTHERWISE, WITH CONTACT SURFACES LEFT UNCOATED. 8.8/TB - HIGH STRENGTH STRUCTURAL BOLTS AS ABOVE, FULLY TENSIONED IN BEARING TYPE JOINT. 20. CONCRETE ENCASED STEELWORK SHALL BE WRAPPED WITH SL41 MESH, UNLESS OTHERWISE SHOWN. 21. FOR CONCRETE ENCASED STEELWORK, PAINTING SHALL EXTEND 100mm INTO THE CONCRETE. THE REMAINDER OF THE ENCASED STEELWORK SHALL BE UNPAINTED AND FREE OF LOOSE RUST, LOOSE MILLSCALE, DIRT, OIL AND GREASE. 22. BEFORE FABRICATION IS COMMENCED, THE LT SUBCONTRACTOR SHALL SUBMIT A HARD COPY OF THE WORKSHOP DRAWINGS TO THE ENGINEER FOR REVIEW. ALLOW 7 WORKING DAYS FOR REVIEW AFTER SUBMISSION. 23. THE SUBCONTRACTOR SHALL PROVIDE AND LEAVE IN PLACE UNTIL PERMANENT BRACING ELEMENTS ARE CONSTRUCTED, SUCH TEMPORARY BRACING AS IS NECESSARY TO STABILISE THE STRUCTURE DURING ERECTION. 24. THE NUMBER OF PURLINS SHOWN IS INDICATIVE ONLY. IT IS THE LT SUBCONTRACTOR'S RESPONSIBILITY TO ENSURE THE CORRECT NUMBER OF PURLINS ARE USED TO SATISFY SPACING REQUIREMENTS. 25. FIX 100 x 70 x 2.5 COLD FORMED ANGLE PURLINS TO SUPPORT DIAGONAL CUT EDGES OF ROOF SHEETING, UNLESS DETAILED OTHERWISE. 26. ROOF AND/OR WALL SHEETING SHALL BE FIXED TO PURLINS OR GIRTS IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN RECOMMENDATIONS. 27. SLOTTED HOLES: WHERE 8.8/TF BOLTS ARE USED IN SLOTTED HOLES, A SPECIAL WASHER OR COVER PLATE, NOT LESS THAN 8mm THICK, IS TO BE USED TO COMPLETELY COVER THE SLOTTED HOLE.
THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL ARCHITECTURAL AND OTHER CONSULTANTS DRAWINGS AND SPECIFICATIONS AND WITH SUCH OTHER WRITTEN INSTRUCTIONS AS MAY BE ISSUED DURING THE COURSE OF THE CONTRACT. ALL DISCREPANCIES SHALL BE REFERRED TO THE ENGINEER FOR DECISION BEFORE PROCEEDING WITH THE WORK. ALL DIMENSIONS RELEVANT TO SETTING OUT AND OFF-SITE WORK SHALL BE VERIFIED BY THE SUBCONTRACTOR BEFORE FABRICATION AND CONSTRUCTION IS COMMENCED. THE ENGINEER'S DRAWINGS SHALL NOT BE SCALED. DURING CONSTRUCTION THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE STRUCTURE IN A STABLE CONDITION AND ENSURE NO PART IS OVER-STRESSED. WORK METHOD STATEMENTS ARE TO BE PREPARED BY THE SUBCONTRACTOR WITH RESPECT TO ANY DEMOLITION / ERECTION OF STRUCTURAL STEEL / CONCRETE / PRECAST CONCRETE ELEMENTS ETC. AND APPROVED BY A REGISTERED ENGINEER. WHERE EXCAVATION WORK IS TO BE CARRIED OUT ADJACENT TO EXISTING FOOTINGS, THE EXACT LEVEL OF THE UNDERSIDE OF THE FOOTINGS SHALL BE OBTAINED BY TEST PITS PRIOR TO EXCAVATION. UNDERPINNING AND SHORING OF THE STRUCTURE SHALL BE CARRIED OUT AS DETAILED AND THE EXISTING STRUCTURE SHALL BE MAINTAINED IN A STABLE AND UNDAMAGED CONDITION. WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH THE RELEVANT CURRENT AUSTRALIAN STANDARDS (INCLUDING ALL AMENDMENTS) AND THE STATUTORY AUTHORITIES' REQUIREMENTS, EXCEPT WHERE VARIED BY THE CONTRACT DOCUMENTS.
Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au
Architect
2.
2. 2.
9.
BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers
3.
3. 27. ALL REINFORCEMENT SHALL BE SECURELY SUPPORTED IN ITS CORRECT POSITION DURING CONCRETING BY APPROVED PLASTIC BAR CHAIRS U.N.O. MINIMUM 25% VOID WITHIN ENCLOSED PERIMETER. MAXIMUM CENTRES OF SUPPORTING CHAIRS SHALL BE 500mm FOR FABRIC, 600mm FOR BARS UP TO 12mm DIAMETER, 800mm FOR BARS 16mm AND GREATER. 28. WHERE NO REINFORCEMENT IS SHOWN ON THE DRAWING AT RIGHT ANGLES TO THE MAIN REINFORCEMENT, PLACE N12-300 TRANSVERSE TO THE REINFORCEMENT SHOWN TO SUIT THE BAR LAYING SEQUENCE. 29. ALL OPENINGS AND RE-ENTRANT CORNERS IN THE CONCRETE SHALL HAVE 2-N12 BARS x 1200 LONG TOP AND BOTTOM CENTRED DIAGONALLY ACROSS THE CORNER. 30. CONSTRUCTION BREAK LOCATIONS AND DETAILS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER PRIOR TO CONSTRUCTION. 31. THE FACE OF ALL CONCRETE WHICH HAS REINFORCEMENT PROJECTING FROM IT AND AGAINST WHICH NEW CONCRETE IS TO BE CAST IS TO BE THOROUGHLY MECHANICALLY SCABBLED, FULLY EXPOSING THE AGGREGATE MATRIX. 32. ALL CONCRETE SURFACES ARE TO BE CURED FOR SEVEN DAYS AFTER CASTING USING A METHOD APPROVED BY THE STRUCTURAL ENGINEER. 33. ALL UN-REINFORCED MASONRY WALLS ARE TO BE SEPARATED FROM ABUTTING CONCRETE WITH TWO LAYERS OF SUPER ALCOR.
OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au
3.
4.
4.
5.
Darwin Australia
5. 6.
6.
4.
7.
8. 5.
9.
6.
ALL DIMENSIONS ARE IN MILLIMETRES UNLESS STATED OTHERWISE. ALL LEVELS ARE EXPRESSED IN METRES. CONSTRUCTION OF ANY MASONRY WALLS OR OTHER PERMANENT LOADING MUST NOT BE BUILT ON CONCRETE SLABS OR BEAMS UNTIL FORMWORK SUPPORTING SAME HAS BEEN REMOVED. HOWEVER PROPS AND FORMWORK SHALL NOT BE REMOVED BEFORE THE MINIMUM TIME SPECIFIED. DISTRIBUTE MASONRY ON SLAB ADJACENT TO ITS FINAL POSITION PRIOR TO CONSTRUCTING WALLS. ALL NON-LOADBEARING WALLS SHALL BE KEPT CLEAR OF THE UNDERSIDE OF SLABS AND BEAMS BY 20mm UNLESS OTHERWISE SHOWN.
10. MINIMUM COVER TO ALL REINFORCEMENT SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE: -----------------------------------------------------------------------------------FORMED FORMED NOT FORMED ITEM NOT EXPOSED EXPOSED TO CAST AGAINST TO WEATHER GROUND, GROUND ETC. WATER, WEATHER ------------------------------------------------------------------------------------COLUMN 50 50 65 ------------------------------------------------------------------------------------BEAM 40 40 65 ------------------------------------------------------------------------------------FOOTING 50 65 ------------------------------------------------------------------------------------SLAB 25 40 65 ------------------------------------------------------------------------------------WALL 25 40 65 ------------------------------------------------------------------------------------11. PIPES OR CONDUITS SHALL NOT BE PLACED WITHIN THE CONCRETE COVER TO REINFORCEMENT. 12. LAPS IN REINFORCING BARS SHALL BE MADE ONLY IN POSITION SHOWN ON THE STRUCTURAL DRAWINGS OR AS OTHERWISE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER. LAPS SHALL BE IN ACCORDANCE WITH THE FOLLOWING TABLE, UNLESS SHOWN OTHERWISE. LOCATION -----------------------------------------------------------------------------------LAPS IN SLABS AND BAR ALL LAPS UNLESS BEAMS WITH MORE TYPE NOTED OTHERWISE THAN 300mm OF CONCRETE BELOW THE BAR -----------------------------------------------------------------------------------N10 400 500 N12 500 650 N16 750 950 N20 1000 1300 N24 1250 1600 N28 1500 2000 N32 1750 2300 -----------------------------------------------------------------------------------13. UNLESS NOTED OTHERWISE ALL SLABS ON GROUND ARE TO BE CAST ON A 250 MICRON THICK POLYTHENE SHEET, LAPPED AND TAPED AT JOINTS, LAID OVER A 50mm MIN. THICK SAND BED. 14. LAPS IN MESH (FABRIC) SHALL COMPLY WITH AS 3600. THE TWO OUTERMOST TRANSVERSE WIRES OF ONE SHEET SHALL OVERLAP THE TWO OUTERMOST TRANSVERSE WIRES OF THE SHEET BEING LAPPED. 15. SIZES OF CONCRETE ELEMENTS DO NOT INCLUDE THICKNESS OF APPLIED FINISHES. 16. BEAM SIZES ARE SHOWN DEPTH FIRST AND INCLUDE SLAB THICKNESS. 17. UNLESS NOTED OTHERWISE ALL FORMED EDGES AND CORNERS OF CONCRETE MEMBERS SHALL HAVE 20mm CHAMFERS. 18. DRIP GROOVES ARE TO BE PROVIDED AT ALL EXPOSED EDGES. COVER TO REINFORCEMENT TO BE MAINTAINED. 19. EXACT SIZE AND LOCATION OF PENETRATIONS ARE TO BE OBTAINED FROM WORKSHOP DRAWINGS PRIOR TO SCHEDULING OF REINFORCEMENT, AND ARE NOT TO EXCEED DIMENSIONS WHERE SHOWN ON STRUCTURAL DRAWINGS.
FA A FA
FR B FR
FI N FI
FC F FC
AB CA AB NA
7. 8.
9.
DEPT NAME
SIGNATURE
2
REV
L290-DS-LAD-10055.001
PURCHASER ORDER NO - SERIAL NO
7.
10. WHERE EXCAVATED SURFACES THAT ARE REQUIRED TO SUPPORT FOUNDATIONS BECOME SOFTENED OR LOOSENED DUE TO ADVERSE WEATHER, ALL AFFECTED MATERIAL SHALL BE REMOVED DOWN TO AN ACCEPTABLE BEARING LEVEL AND REPLACED IMMEDIATELY WITH A 10 MPa BLINDING LAYER.
CTR DOC NO
V-31D1-BLD-1-Z24051
10. ALL BOLTS, NUTS AND WASHERS INCLUDING H.D. BOLTS ARE TO BE HOT DIP GALVANISED. ALL CAST IN FERRULES AND MASONRY ANCHORS TO BE HOT DIP GALVANISED. ALL GALVANISED COMPONENTS TO BE CAST INTO CONCRETE MUST BE PASSIVATED. 11. THE FOLLOWING STEELWORK SHALL BE HOT DIP GALVANISED: PLATE/ANCHOR ROD ASSEMBLIES CAST INTO CONCRETE. ALL MEMBERS BUILT INTO BRICK OR BLOCKWORK. 12. ALL COLD FORMED PURLINS AND GIRTS ARE TO BE MANUFACTURED FROM ROLL-FORMED GALVANISED STEEL COMPLYING WITH AS 1397. STEEL SHALL BE GRADE G450 FOR BASE METAL THICKNESSES 1.5 AND GREATER, GRADE G500 FOR BMT OF 1.2, AND GRADE G550 FOR BMT OF 1.0. - ALL COLD FORMED MEMBERS TO HAVE A MINIMUM COATING MASS OF 350g/sq.m EXCEPT FOR THE FOLLOWING AREAS, WHICH ARE TO HAVE A MINIMUM COATING MASS OF 450g/sq.m: - ALL MEMBERS IN EXTERNAL, EXPOSED ENVIRONMENTS - ALL WALL AND ROOF FRAMING TO DANGEROUS GOODS STORE. 13. ALL STRUCTURAL STEEL FIXING DETAILS ARE TO BE BASED ON A.S.I. STANDARDISED STRUCTURAL CONNECTIONS, UNLESS NOTED OTHERWISE. ALL BOLT HOLES 2mm OVERSIZE U.N.O. HOLES FOR H.D. BOLTS 6mm OVERSIZE U.N.O. OVERSIZE HOLES FOR H.D. BOLTS WILL REQUIRE OVER SIZE WASHERS UNDER NUTS. BOLT HOLES IN STEELWORK CONNECTING TIMBER SHALL PROVIDE A SNUG FIT, I.E. NOT GREATER THAN 0.5mm LARGER THAN BOLT DIAMETER. 14. STIFFENER PLATES WHERE DETAILED ARE TO BE PLACED ON BOTH SIDES OF WEB TO U.B.'S AND U.C.'S. 15. THE ENDS OF ALL TUBULAR MEMBERS ARE TO BE SEALED WITH 6mm THICK PLATES AND CONTINUOUS SEAL WELDS, UNLESS DETAILED OTHERWISE. 16. ALL HOLES IN PLATES AND STEEL MEMBERS SHALL BE DRILLED, EXCEPT FOR PURLIN AND GIRT HOLES WHICH MAY BE PUNCHED. 17. WHERE DETAILS PREVENT THE NORMAL INSTALLATION OF C.F.W.'S, GRIND THE EDGE OF THE MEMBER TO FACILITATE THE INSTALLATION. 18. CLEANING AND PAINTING OF STRUCTURAL STEELWORK ABRASIVE BLAST CLEAN TO CLASS 2 12 MIN PROTECTIVE COATING REQUIREMENTS: - STEELWORK IN INTERNAL, CONDITIONED ENVIRONMENTS: PROVIDE ONE COAT OF INORGANIC ZINC SILICATE PRIMER MIN. DRY FILM THICKNESS 75 MICRONS. - STEELWORK IN INTERNAL, NON-CONDITIONED ENVIRONMENTS: PROVIDE ONE COAT OF INORGANIC ZINC SILICATE PRIMER MIN. DRY FILM THICKNESS 125 MICRONS. - STEELWORK IN EXTERNAL ENVIRONMENTS (OUTSIDE OF BUILDING ENVELOPE): HOT DIP GALVANISED IN ACCORDANCE WITH AS4680. ALL ASPECTS OF THE PREPARATION AND OF THE SYSTEM ARE TO BE CARRIED OUT IN STRICT ACCORDANCE WITH THE MANUFACTURER'S WRITTEN RECOMMENDATIONS. 19. ALL STRUCTURAL STEELWORK BELOW GROUND TO BE ENCASED BY N25 CONCRETE 75mm ALL ROUND, UNLESS NOTED OTHERWISE.
8.
CONCRETE
1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS 3600 AND AS1379. CONCRETE STRENGTH GRADE FOR PARTICULAR ELEMENTS SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE: AREA CONC. STRENGTH (MPa) - STRIP/PAD FOOTING N25 - SLAB ON GROUND - INTERNAL AREAS, N25 SEALED BUILDINGS - SLAB ON GROUND - INTERNAL AREAS, S40 INDUSTRIAL FLOOR AREAS TO BUILDINGS F, A, E AND S - SLAB ON GROUND - EXTERNAL AREA S32 - EXTERNAL ROAD PAVEMENTS AND REFER CIVIL LAY DOWN AREA DWG - ROTOR STORAGE AREA S40 - SUSPENDED SLABS - INTERNAL AREA N32 - SUSPENDED SLABS - BUILDING E S32 - BLOCKWORK CORE FILL N20 - CONCRETE WALLS S40 NOTE: CONCRETE NOTED AS SPECIAL CLASS TO CONFORM TO AS1379 REQUIREMENTS FOR B2 EXPOSURE PREFIX SB. 3. MAX. AGGREGATE SIZE = 20mm SLUMP = 80mm +/- 15mm (AT POINT OF DISCHARGE) NO 'BRECCIA' TYPE AGGREGATE IS TO BE USED. THE CONTRACTOR IS TO NOTIFY THE STRUCTURAL ENGINEER IN WRITING OF ANY ADMIXTURES TO BE USED IN THE CONCRETE MIX. NO ADMIXTURES SHALL BE USED WITHOUT WRITTEN APPROVAL BY THE STRUCTURAL ENGINEER. CALCIUM CHLORIDE WILL NOT BE PERMITTED AND SHALL NOT BE USED UNDER ANY CIRCUMSTANCES. CONCRETE TESTING - REFER CONCRETE SPECIFICATION ALL FORMWORK SHALL CONFORM TO AS 3610. RESHORING IS NOT PERMITTED.
9.
THE STRUCTURAL WORK SHOWN ON THESE DRAWINGS HAS BEEN DESIGNED FOR THE LIVE LOADS AS NOMINATED IN THE STRUCTURAL ENGINEERING DESIGN REPORT. SPECIFIC DESIGN LIVE LOADS ON SUSPENDED STRUCTURE AS FOLLOWS: AREA ROOF - CCB ROOF - ALL OTHER BUILDINGS WAREHOUSE MEZZANINE LEVEL SUSPENDED CONCRETE CEILINGS LIVE LOAD (kPa) 1.8 0.25 9.6 5.0
2.
"CHEMSET MAXIMA CAPSULES" DENOTES RAMSET CHEMSET MAXIMA SPIN CAPSULES WITH STUDS AND EMBEDMENTS AS DEFINED IN NOTE 1. "TRUBOLTS" DENOTES RAMSET TRUBOLT HOT DIPPED GALV. STUD ANCHORS WITH THE FOLLOWING MINIMUM EMBEDMENTS: M12 TRUBOLTS M16 TRUBOLTS M20 TRUBOLTS 80mm EMBEDMENT U.N.O. 110mm EMBEDMENT U.N.O. 135mm EMBEDMENT U.N.O.
3.
10. IMPORTANCE LEVEL HAS BEEN DETERMINED FOR EACH BUILDING IN ACCORDANCE WITH BCA TABLE B1.2 AND ARE AS FOLLOWS: BUILDING CENTRAL CONTROL BLG IMPORTANCE LEVEL 4 (1:10000 RETURN PERIOD FOR WINDLOADING) 4 (1:2000 RETURN PERIOD FOR WINDLOADING) 2 (1:500 RETURN PERIOD FOR WINDLOADING)
4.
"CHEMSET 101 ANCHORS" DENOTES RAMSET GRADE 5.8 HOT DIPPED GALV. STUDS, FIXED WITH AN EFFECTIVE DEPTH OF 64mm INTO EXTRUDED BRICK OR HOLLOW CONCRETE BLOCK, USING THE MANUFACTURER'S SLEEVES/SIEVES AND RAMSET CHEMSET INJECTION 101. ALL ANCHORS ARE TO BE FIXED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN RECOMMENDATIONS.
5.
11. WIND LOADING HAS BEEN DETERMINED IN ACCORDANCE WITH AS/NZS 1170.2 WIND ACTIONS, USING THE FOLLOWING VALUES:
4.
WIND REGION C TERRAIN CATEGORY 2.0 SHIELDING MULTIPLIER 1.0 TOPOGRAPHIC MULTIPLIER 1.0 INTERNAL PRESSURE COEFFICIENT Cp,i +0.7, -0.65 REGIONAL WIND SPEED, VR 1:10000 - 85m/sec 1:2000 - 76.7m/sec 1:500 - 69.3m/sec
2.
3.
5. 6.
AA NO
ISSUE PURPOSE
SWS CKD
DDG APP
REVISIONS
12. EARTHQUAKE LOADING HAS BEEN DETERMINED IN ACCORDANCE WITH AS/NZS 1170.4 USING THE FOLLOWING VALUES: SOIL CLASS HAZARD FACTOR (z) PROBABILITY FACTOR (kp) Ce 0.09 I.L. 4 - 1.5 I.L. 2 - 1.0 EARTHQUAKE DESIGN CATEGORY (EDC) II
7.
THE LT SUBCONTRACTOR IS RESPONSIBLE FOR THE DESIGN 20. DO NOT CUT REINFORCEMENT ON SITE TO CLEAR AND CONSTRUCTION OF ALL CONCRETE FORMWORK. PENETRATIONS. DISPLACE REINFORCEMENT SLIGHTLY AS WHEN REQUESTED SUBMIT THE FOLLOWING NECESSARY. DOCUMENTATION: FORMWORK DRAWINGS, IN ACCORDANCE WITH CLAUSE 4.7 OF AS 3610. CERTIFICATION BY A QUALIFIED STRUCTURAL ENGINEER EXPERIENCED IN FORMWORK DESIGN VERIFYING THAT THE DESIGN CONFORMS WITH RELEVANT REQUIREMENTS. CERTIFICATION BY A QUALIFIED STRUCTURAL ENGINEER EXPERIENCED IN FORMWORK DESIGN AND CONSTRUCTION VERIFYING THAT THE COMPLETED FORMWORK IS STRUCTURALLY ADEQUATE FOR ITS INTENDED PURPOSE. 21. NO CHASES, HOLES GREATER THAN 150mm DIAMETER, OR EMBEDMENT OF PIPES GREATER THAN 40mm DIAMETER OTHER THAN THOSE SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE MADE IN THE CONCRETE SLABS. FOR ALL OTHER CONCRETE MEMBERS NO PENETRATION, CHASES OR EMBEDMENTS SHALL BE MADE WITHOUT PRIOR APPROVAL BY THE STRUCTURAL ENGINEER. 22. CONDUITS CAST INTO CONCRETE MEMBERS SHALL BE SPACED AT MAXIMUM DISTANCE POSSIBLE AND UNDER NO CIRCUMSTANCES CLOSER THAN A CLEAR SPACING OF TWICE THE LARGER CONDUIT DIAMETER FROM PARALLEL REINFORCEMENT OR ANY OTHER CONDUIT. 23. REINFORCEMENT IS SHOWN DIAGRAMMATICALLY AND NOT NECESSARILY IN TRUE PROJECTION.
4.
5.
1 : 100 2
LEICON REV
REVIEW CLASS
LEIGHTON DWG NO
Q1447-V-31D1-BLD-1-Z24051
JKC DWG NO
AA
SIZE
V-31D1-BLD-1-Z24051
COMPANY DWG NO
A1
COY REV
L290-DS-LAD-10055.001 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16