Explanation of symbols
Symbol Explanation
Enter numbers, keys, password, internal or external numbers, etc. Signaling with a short beep
d
Consultation 2nd Call
Press the Flash/Fil key. Service Menu/Feature key Programmable key deleted Programmable key is ON Blinking programmable key and Navigation keys
Numbering plan
Description
External line Extension, including S0 Group of external lines Internal subscriber group Hunt Groups (HG) UCD subscriber group Carrier EVM - Default internal number EVM - Message ports EVM - Virtual ports Fax/DID - Virtual message ports USB/CAPI line Substitution for * and # 10 75 and 76 (accordingly) HiPath 1120 801 to 808 11 to 30 HiPath 1150 801 to 832 11 to 60 610 to 645 0, 890 to 899 770 to 779 780 to 789 790 to 799 9 790 7491 to 7492 744 to 747 740 to 743 100 HiPath 1190 801 to 845 101 to 240
Profiset 3030
3 lines or
E822 ST
2 lines
E821 ST
-----
g
---
dv
-----
J
d
----jv
J
d
---
-----
jj
jj
e b a
Display indications
Profiset 3030
1 2 3
>
The first line displays time and date. The second line displays information such as the number of the extension called and system messages. The third line displays the extension number and system messages pertaining to feature selection options. When ">" or "N" symbol appears next to the line, it means there are additional selection options. To scroll through the available options use the navigation keys. To select an option press the Enter key. When the " " or " " symbol appears next to the line, it means there are additional lines to display. Select the Menu key to access the next line or the previous line.
E822 ST
1 2
>
The first line displays time, date, day of the week, number of the extension called, and number of system messages. The second line displays the extension number and system messages pertaining to feature selection options. If the ">" appears on the right, it means there are more selection options available. To navigate through the options use the arrow keys. To select an option press the confirmation key.
Key 1 Key 2
Mute/InterRedial
Key 3 Key 12 Key 4 Key 13 Key 5 Key 14 Key 6 Key 15 Key 7 Key 8 Virtual End Key 16
Notes: The Mute/Internal key will function as Internal when Automatic seizure of an external line is activated. in all other cases it functions as Mute. On the E821 and E822 ST system telephones the Mute function cannot be assigned to a programmable key. On E 821 ST system telephones the Redialkey functions as a Consultation. See the User manual (A31003-K1160-B802-*) or the HiPath 1100 Manager for information on how to program keys. Labels for programmable keys can be printed/changed using the "Printing Labels" service on the HiPath 1100 Manager. System telephone settings can be configured individually according to each users preferences. For further information on how to configure a system telephone, see the manual included with the unit.
Feature
Features can be selected as follows: 1. Using the navigation keys in the Main Menu 2. Using the Feature key then browsing the feature option list 3. Using the Feature key and its associated Feature Code 4. Using a programmable key 5. Using the feature code
qji
Call forwarding Call forwarding Parking Parking
p d to mslot d to m slot
d
qhmf rhmf rlf p list qme
Select a key feature to be programmed and and
Redial
Redial or
Speaker
Activate/deactivate speakerphone
g
Activate/deactivate speaker
g
Virtual keypadl Virtual keypad Virtual keypad Checking relay status = the "Virtual keypad" is active = "Main keypad" is active
qmheh
Code
dp lmd.lmm p external line lde.lhi p qhmg p external line rhmg p external line
1)Wait for or 2) external
Code
p number
wait
Speakerphone auto-answering mode Activation Speakerphone auto-answering mode Deactivation Direct communication call
w s record messagem
Internal call
p extension
5
Calling a call group (CG) Calling a Hunt group (HG) Calling a UCD subscriber group Urgent Call (busy extension)
ns n p
Wait
busy
LCR Bypass View timeout Silent Monitoring busy extension Recall Activation (Extension does not answer or is busy)
p no answer
RECALL?
or
qil w .
Wait. Phone rings or 2) Wait for
ns
Wait. Phone rings Callback Deactivation Carrier Using a temporary MSN to make a call
w t. ns
ril m qhe p MSN slot or MSN number p external line p external number
Code
p number ps
qg s
Consultation
Consultation (To end a consultation, wait for the call to be disconnected) Parking Retrieving a parked call Retrieving a parked external call Toggle (Use after consultation for answering a second or urgent call)
qij + d.m
qf s
s + p data
(if busy or no answer)
qd
Transfer (When an external analog line programmed as Type of answering signal or a digital line is being used, you must wait for an answer before transferring the call. For transfers without consultation, there is no need to wait before answering)
Internal
s p extension t
External
TRANSFER?
pnumber
Code
p
or or
qii qf s
CALL WTNG?
Group pickup
qik
or
qim p extension qee p external line qee p extension, voice mail group, call group
or Fax/DID
Call forward no answer or busy Deactivation Do not disturb Activation Do not disturb Deactivation EVM: Consultation at the extension being used Consultation from another extension
Miscellaneous functions
Feature
External door extension Door opening
Code
or
rmheh p password qmg p current password p new password p confirm new password w qjj p password rjj p password qmhee rmhee qmi p password w p codes rd
Electronic lock Activation Electronic lock Deactivation Busy signal when extension is busy Activation Busy signal when extension is busy Deactivation System programming mode Activation Deactivating Features (Call forwarding, do not disturb, headset, data protection, alarm clock, callback and speakerphone autoanswering) Language/Country settings Call group (CG) and Hunt group (HG) Login Call group (CG) and Hunt group (HG) Logout Room monitor (Babyphone) Music on Hold Activation Music on Hold Deactivation Remote configuration HiPath 1100 Manager Remote configuration Using an MF telephone
qli p group (if it belongs to more than one rli p group (if it belongs to more than one qll w s qmhed rmhed qmmf
Music
group)
qmme w t
qhmd w
8
Data protection Deactivation Relay Activation (only for HiPath 1120) Relay Activation (only for HiPath 1120) Night service Activation Night service Deactivation Call waiting tone Activation Call waiting tone Deactivation COS (Class of service) Changeover
rhmd w qmd rmd qhh p password rhh p password n rlk w t n qlk w t qidl p extension p password s
Alarm clock
Feature
Alarm clock (Daily) Alarm clock (Daily, except weekends) Alarm clock (After a specified time period) Alarm clock (For a specified date and time) Alarm clock Deactivation
Code
qhje p time (e.g 1230) qhjf p time (e.g 1230) qhjg p time (e.g 1230) qhjh p date/time (e.g 24121830) rhj
Code
qhde p group (if the extension belongs to rhde qhdg rhdg qhdi
Satellite PABX
Feature Code
Code
qjhe p external w p MSN rjhe w qjhf p external w p MSN rjhf w qjhg p external w p MSN rjhg w qlh qlj rlj qidg p external p ISDN code
Note 1: For Korea the numbering plan changes as follows: a) Access to the group of external lines is done with digit "9" instead of "0" b) Calling an operator terminal is done with digit "0" instead of "9" c) Group call pickup is done with sequence "*0" instead of "*57" d) Recovery of a parked call is done with sequence "*57" instead of "*0" Note 2: Feature codes can be changed with the HiPath 1100 Manager. An expert should be consulted in this case.
10
www.siemens.com/enterprise
The information provided in this document contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as the result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of the contract. All trademarks are the property of Siemens Enterprise Communications GmbH & Co. KG or their respective owners.