HEPA-filtered vertical laminar airflow which is recirculated in the work zone creates an ultra-clean work environment for product protection. An air barrier between the operator and the work zone is maintained by a flow of room air into a full width grille in the work opening. All positive pressure zones and filter seals are surrounded by negative pressure zones, so as to contain potentially hazardous aerosols.
HEPA-filtered vertical laminar airflow which is recirculated in the work zone creates an ultra-clean work environment for product protection. An air barrier between the operator and the work zone is maintained by a flow of room air into a full width grille in the work opening. All positive pressure zones and filter seals are surrounded by negative pressure zones, so as to contain potentially hazardous aerosols.
HEPA-filtered vertical laminar airflow which is recirculated in the work zone creates an ultra-clean work environment for product protection. An air barrier between the operator and the work zone is maintained by a flow of room air into a full width grille in the work opening. All positive pressure zones and filter seals are surrounded by negative pressure zones, so as to contain potentially hazardous aerosols.
Biological Safety Cabinets are partly-recirculating laminar
airflow enclosures with high efficiency particulate air (HEPA) filtration of exhaust air and an air barrier at the work opening. HEPA-filtered vertical laminar airflow which is recirculated in the work zone creates an ultra-clean work environment for product protection. An air barrier between the operator and the work zone is maintained by a flow of room air into a full width grille in the work opening. The barrier air mixes with the laminar flow air in a sump underneath the work surface, and is exhausted to the outside environment via a HEPA filter and an optional virus burn-out. All positive pressure zones and filter seals are surrounded by negative pressure zones, so as to contain potentially hazardous aerosols.
HEPA FILTER Media Glass fiber paper - imported
Particle retention 0.3 micron
Efficiency 99.97 % Pressure drop 23 mm WG Size - at supply 48" x 24" x 6" 1 Number Size - at Exhaust 12" x12" x 6" 1 Number PRE FILTER Media Non woven - synthetic polyester
Particle retention 10 - 15 micron
Efficiency 90 % Pressure drop 6 mm WG Size 800 x 400 x 60 mm By 1/3 HP, single phase, 1440 RPM motor, directly coupled with a pair of Blower Assembly aluminum, centrifugal impeller. Capacity 1000 CFM, Pressure 30 mm WG
By ¼ HP, Single phase, 1440 RPM motor, directly coupled with a
Exhaust Assembly aluminum impeller. Capacity - 300 CFM, Ducting by PVC pipe with rain guard - DIA - 150 mm Ultra violet lamp 3 feet, 30 Watt - 1 No Illumination 4 feet, 40 Watt - with diffusers Pressure manometer, Additional power point, Gas inlet nozzle, floor Standard accessories leveling screws, wire chord Power supply 240 V, single phase, 50 Hz