A

A B C D E F G H I J COLD WATER INLET 1-1/4" HOT WATER INLET 1-1/4" AUX WATER INLET 1-1/4" ELECTRICAL CONNECTION CHEMICAL SIGNAL CONNECTION STEAM INLET 1" DRAIN CONNECTION 4" AIR INLET 3/8" GREASE POINTS EXTERNAL CHEMICAL INLETS

H A D E I B C F

Electrical Requirements
Voltage 208-240VAC, 50/60Hz, 3PH 380-460VAC, 50/60Hz, 3PH Phase System Wire Wire Size 3 3 + GND 6 3 3 + GND 12 Amps 58 29 Breaker 60 30

Drain Requirements
FRONT
Flow Rate (@45PSI/3Bar) gal/min liter/min 37 140 Max Operating Pressure US Metric 100 PSI 6 Bar Minimum Supply Line Size US Metric 1-1/2 DN 38 Max Operating Pressure US Metric 125 PSI 8 Bar
Dynamic pressure kN/m2 lbs/ft2 81 3.9 Dynamic Frequency Hz 11.67
BY

Connection Size inches mm 4 102

Discharge Rate gal/min liters/min 150 560

Min Sewer Line inches mm 5 127

Water Requirements
Connection Size US Metric 1-1/4" DN 32 Water Line Pressure PSI Bar 30-75 2-5 Max Temp F C 200 93 Minimum Supply Line Size US Metric 1" DN 19

Steam Requirements
Steam Connection Size Line Pressure US Metric PSI Bar 1" DN 25 30-75 2-5

Dynamic Load Specifications


Static floor load kN lbs 24.53 5514 Static pressure kN/m2 lbs/ft2 179 8.6 Total Dynamic Load kN lbs 11.1 2505
REV DATE REV. DESCRIPTION

Shipping Data
Type Domestic Export lbs 4697 4763 kg 2135 2165 cu ft 222 222 cu m 6.3 6.3

A1
DRAWN BY CHECKED BY

AFA

9-30-2013
DATE DATE

Created
Panama City, FL Phone: 850-249-2222 Fax: 850-249-2226 www.bandctech.com

A. Adcock 9-30-2013 C. Oswald 9-30-2013


DESCRIPTION

General Technical Specifications

SP-195
DATE FILE NAME SHEET

9-30-2013

SP-195GenSpec.cdr