DESIGN IS BASED FOR 10 OUTLET FROM THE CLOSE LOOP

DIA
FRICTION FACTOR

65 MM
0.0163 M

FLOW FROM EACH JUNCTION


FLOW
FIRST TRAIL
PIPE
AB
BC
CD
DE
EF
AG
GF

SECTION

ASSUME FLOW ACTUAL FLOW


LENGTH (M) HL (M)
HL/Q
4.44
4.44
10.88 0.2492168 0.05613
3.33
3.33
1.5 0.0193269 0.005804
2.22
2.22
13.43 0.0769068 0.034643
1.11
1.11
13.43 0.0192267 0.017321
0
0
1.96
0
0
-2.22
-2.22
2.55 -0.014603 0.006578
-1.1
-1.1
13.43 -0.018882 0.017165
7.78
0.3311928 0.137641
GO FOR SECOND TRIAL

SECOND TRAIL
PIPE
AC
BC
CD
DE
EF
AG
GF

PREVIOUS FLOW ACTUAL FLOW


LENGTH (M) HL (M)
HL/Q
4.44
3.236894797
5.45 0.0663493 0.020498
3.33
2.126894797
1.5 0.0078843 0.003707
2.22
1.016894797
6.715 0.0080683 0.007934
1.11
-0.093105203
6.715 -6.76E-05 0.000726
0
-1.203105203
1.95 -0.00328 0.002726
-2.22
-3.423105203
1.275 -0.017359 0.005071
-1.1
-2.303105203
6.715 -0.041386 0.01797
0
-0.641736424
0.020209 0.058632
GO THIRD TRIAL

PIPE
AC
BC
CD
DE
EF
AG
GF

PREVIOUS FLOW ACTUAL FLOW


LENGTH (M) HL (M)
HL/Q
3.236894797
3.064558012
5.45 0.0594723 0.019406
2.126894797
1.954558012
1.5 0.0066584 0.003407
1.016894797
0.844558012
6.715 0.0055653 0.00659
-0.093105203
-0.265441988
6.715 -0.00055 0.002071
-1.203105203
-1.375441988
1.95 -0.004286 0.003116
-3.423105203
-3.595441988
1.275 -0.019151 0.005327
-2.303105203
-2.475441988
6.715 -0.047812 0.019314
-0.641736424
-0.814073208
-0.000103 0.059231

OK