Reliability data of Omron components

Below tables show the reliability data of Omron components and give a reference to the relevant standard: Emergency stop switches
Model name B10d A165E 100.000 A22E 100.000 1) ER5018 1.500.000 ER6022 1) 1.500.000 1) ER1022 1.500.000 ER1032 1) 1.500.000 1) at 100mA switching current remarks Adopted EN ISO 13849-1 Annex C, B10d fixed Adopted EN ISO 13849-1 Annex C, B10d fixed Adopted EN ISO 13849-1 Annex C, B10d fixed Adopted EN ISO 13849-1 Annex C, B10d fixed, additionally valid for all XER and stainless steel models Adopted EN ISO 13849-1 Annex C, B10d fixed, additionally valid for all XER models Adopted EN ISO 13849-1 Annex C, B10d fixed, additionally valid for all XER models

Safety limit switches


Model name B10d remarks D4B-_N 2) 2.000.000 From table in annex C of EN ISO 13849-1 D4N 2) 2.000.000 From table in annex C of EN ISO 13849-1 D4NH 2) 2.000.000 From table in annex C of EN ISO 13849-1 2) D4N-_R 2.000.000 From table in annex C of EN ISO 13849-1 D4F 2) 2.000.000 From table in annex C of EN ISO 13849-1 2) If fault exclusion for direct opening action of NO and NC is possible.

Safety door switches


Model name B10d PL Category D4NL 2.000.000 n.a. n.a. D4GL 3) 2.000.000 n.a. n.a. D4BL 3) 2.000.000 n.a. n.a. D4NS 2.000.000 n.a. n.a. 3) D4BS 2.000.000 n.a. n.a. F3S-TGR-N_C 3.300.000 n.a. n.a. F3S-TGR-N_R 3.300.000 n.a. n.a. D40A + G9SX-NS n.a. d 3 3) If fault exclusion for direct opening action is possible. MTTFd n.a. n.a. n.a. n.a. n.a. n.a. n.a. 100 years DC n.a. n.a. n.a. n.a. n.a. n.a. n.a. 95% Remarks Adopted EN ISO 13849-1 Annex C, B10d fixed From table in annex C of EN ISO 13849-1 From table in annex C of EN ISO 13849-1 Adopted EN ISO 13849-1 Annex C, B10d fixed From table in annex C of EN ISO 13849-1 Adopted EN ISO 13849-1 Annex C, B10d fixed Adopted EN ISO 13849-1 Annex C, B10d fixed Adopted EN ISO 13849-1 Annex C, PL data fixed

Safety sensors
Model name MS2800E_ MS4800E_ F3S-TGR-CL2_ F3S-TGR-CL4_ B10d n.a. n.a. n.a. n.a. PL c e c e Category 2 4 2 4 MTTFd 51 years 51 years 450 years 450 years DC 99% 99% 99% 99% Remarks Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed

Safe control systems


Model name G9SA-301 G9SA-300-SC G9SB-series 4) G9SB-3010 G9SX-BC G9SX-AD G9SX-ADA G9SX-EX G9SX-SM G9SX-LM NE1A-SCPU01 NE1A-SCPU02 NE0A-SCPU01 DST1-ID12SL-1 DST1-MD16SL-1 DST1-MRD08SL-1 DST1-XD0808SL-1 4) Except G9SB-3010 B10d n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. PL e e e d e e e e e d e e e e e e e Category 4 4 4 3 4 4 4 4 4 3 4 4 4 4 4 4 4 MTTFd 100 years 100 years 100 years 100 years 100 years 100 years 100 years 100 years 100 years 100 years 100 years 100 years 100 years 100 years 100 years 100 years 100 years DC 99% 99% 99% 99% 97% 97% 97% 99% 98% 82% 99% 99% 99% 99% 99% 99% 99% Remarks Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed Adopted EN ISO 13849-1 Annex C, PL data fixed

Safe actuators
Model name B10d remarks G7SA 5) 400.000 According to IEC 61810-1, valid for DC13, Inductive load Ie 5) G7SA 400.000 According to IEC 61810-1, valid for DC13, Inductive load Ie/2 G7SA 5) 400.000 According to IEC 61810-1, valid for DC13, Inductive load Ie/4 G7SA 5) 400.000 According to IEC 61810-1, valid for AC15 load 5) Refer to the load characteristic to select correct B10d value

Please check Omron in the Internet for updated information and SISTEMA library: http://industrial.omron.eu/safety Status: September 30th, 2009 OMRON EUROPE B.V.