Inputs
Height of V notch above channel invert, P = 2.6 ft P/(2Hmax) > 1 ? Distance from channel wall to V notch edge at top of overflow, S = 2.6 ft S/(2Hmax) > 1 ? Max. head expected over weir, Hmax = 1.25 ft 0.2 ft < H < 1.25 ft ? yes yes S/(2Hmax) = 1.04 yes
Calculations
P/(2Hmax) = 1.04
Notch Angle, q =
75
degrees
0.576
0.0031
Flow Rate, Q =
0.580
cfs
[ Ce = 0.607165052 - (0.000874466963) + (6.10393334 x 10-6)2 ] [ k = 0.0144902648 - (0.00033955535) + (3.29819003 x 10-6)2 - (1.06215442 x 10-8)3 ]
14 15
roughness, n =
0.0000